• 제목/요약/키워드: Force touch

검색결과 94건 처리시간 0.029초

고령자의 태권도 앞굽이서기 운동과 보행의 지면반력 특성비교 (Characteristic Comparison of Ground Reaction Force of the Taekwondo's Apkubi Motion and the Walking on Older Persons)

  • 배영상;김기만
    • 한국운동역학회지
    • /
    • 제21권3호
    • /
    • pp.289-296
    • /
    • 2011
  • The purpose of this study was to quantify the biomechanical characteristics of the ground reaction force(GRF) during the Taekwondo's Apkubi, one of the basic movement in Taekwondo and the walking. The GRF profiles under the stance foot of Apkubi movement and walking were directly measured in sample of 20 healthy older persons. In the anterior-posterior and vertical direction, the GRF of the Apkubi movement reached to the peak braking force at 10% of the normalized stance time percent and the peak driving force at 90% of stance time, but that of the walking reached to the peak braking force at 20% of stance time and the peak driving force at 80% of stance time. In vertical force, the GRF of the walking showed two peak values, but that of the Apkubi movement seemed three peak values. Moreover the first peak vertical force was significantly(t=6.085, p<.001) greater in the walking(about 1.8 times of body weight) than the Apkubi(about 1.4 times of body weight). The walking velocity was affected significantly(over p<.05) by the braking impulse, the peak braking force and the first peak vertical force. Futhermore the peak braking force in the Apkubi showed a significant effect on the Apkubi's stride length(p<.01). So, we concluded that the braking force after the right touch down, the stance foot on the ground contributed to move the leg forward.

다자유도 탄소섬유판 힘/토크 센서 개발 (Development of Multi-Degree of Freedom Carbon Fiber Plate Force/Torque Sensor)

  • 이동혁;김민규;조남규
    • 한국정밀공학회지
    • /
    • 제29권2호
    • /
    • pp.170-177
    • /
    • 2012
  • A force/torque sensor using carbon fiber plate was designed and developed to make the sensor be able to measure a wide range of multi degree of force and torque. Using carbon fiber plate of 0.3 mm thickness, the sensor was designed and developed, which has a ${\mu}N$ level order of resolution and about 0.01 N ~ 390 N of wide measurement range. The elastic deformation part has a tripod plate structure and strain gauges are attached on the part to detect the force/torque. The coefficient of determination for the sensor is over 0.955 by the calibration experiment so that the linearity of the sensor is confirmed to be good. Also, experiments on applying 0.005 ~ 40 kg (0.05 ~ 390 N) to each axis were implemented and the sensor is proved to be safe under a high load. Finally, to verify the function calculating the direction of load vector, the directions of various load vectors which have the same magnitude but different directions and the directions of the calculated load vectors are compared and analyzed to accord well.

전자 종이용 하전 입자의 부착력 분석 (Adhesion Force Analysis of Charged Particles for the E-paper)

  • 김승택;김형태;이상호;김종석
    • 반도체디스플레이기술학회지
    • /
    • 제9권4호
    • /
    • pp.87-91
    • /
    • 2010
  • Charged micro-particles are widely used as the key components for many electrical applications such as an e-paper, a touch panel, a printer toner and an electronic ink. Among them, the e-paper is an emerging reflective type display using the charged particles that has the advantages of the extremely low power consumption and sunlight readability. To create images on the e-paper, we confine black positively-charged and white negatively-charged particles between bottom and top electrodes and selectively apply the electric field. When the Coulomb force by an applied electric field is greater than the adhesion force between the charged particle and the electrode, the particles' transition happens resulting in the change of color between black and white. Therefore, the adhesion force is a very important factor for designing and estimating e-paper's operation. In this study, we constructed a basic model for particle's transition and an adhesion force equation describing particle's transition with three different forces: electrostatic image force, Van der Waals force and gravitational force. The simulation results showed that the gravitational force is negligible for the interesting range for the charge and the radius, and the adhesion force can be strongly dependent on the particle's charge and radius.

Biomimetic Hopping Strategy for Robots

  • Sung, S.H.;Youm, Y.;Chung, W.K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2654-2659
    • /
    • 2003
  • In this paper, we present biomimetic hopping strategy which is more human-like for legged robot through stiffness modulation. Stiffness value is calculated from the motion of body center of gravity. This method enable to reduce impact force on touch-down, adaption on ground stiffness change and height modulation. Simple selected models will be used to validate this method. For general model, singular perturbation is used for control and simulation using stiffness modulation is presented.

  • PDF

초음파 모터를 이용한 힘 반영 촉각장치 (A Force-Reflecting Haptic interface using Ultrasonic Motors)

  • 신덕;오금곤;김영동
    • 조명전기설비학회논문지
    • /
    • 제13권1호
    • /
    • pp.111-118
    • /
    • 1999
  • 함반영 촉각장치(Force-Reflecting haptic Interface)는 인간이 컴퓨터에 의해 생성한 가상의 세계에 손의 위치 정보를 제공하고 가상의 손이 가상 환경에 접촉했을 때 인간에게 촉각을 전달하는 장치이다. 본 논문에서는 컴플라이언스 제어가 비교적 용이한 초음파 모터 액츄에이터를 사용하여 직접구동 방식으로 촉각장치를 설계하였다. 렌더링 알고리즘을 이용하여 가상의 벽, 가상 버튼, 가상 구멍 등의 기본적인 역감실험을 한 결과 힘 반영에 의한 역감을 제시받을 수 있었다.

  • PDF

고관절 구동 방식을 갖는 바퀴-다리형 로봇과 지면 간 접촉점에서의 마찰계수 추정 (Estimation of the Frictional Coefficient of Contact Point between the Terrain and the Wheel-Legged Robot with Hip Joint Actuation)

  • 신동환;안진웅;문전일
    • 로봇학회논문지
    • /
    • 제6권3호
    • /
    • pp.284-291
    • /
    • 2011
  • This paper presents the estimation of the frictional coefficient of the wheel-legged robot with hip joint actuation producing maximum tractive force. Slip behavior for wheel-legged robot is analytically explored and physically understood by identification of the non-slip condition and derivation of the torque limits satisfying it. Utilizing results of the analysis of slip behavior, the frictional coefficients of the wheel-legged robot during stance phase are numerically estimated and finally this paper suggests the pseudo-algorithm which can not only estimate the frictional coefficients of the wheel-legged robot, but also produce the candidate of the touch down angle for the next stance.

자동귀환 서랍의 감성품질에 대한 설계인자 영향 분석 (Effects of Design Parameters on the Ergonomic Quality of a Self-Closing Drawer)

  • 서만철;김권희
    • 한국정밀공학회지
    • /
    • 제33권8호
    • /
    • pp.655-660
    • /
    • 2016
  • Self-closing drawers are used in high-end products, such as furniture, home appliances, and a range of other storage devices. In this study, a self-closing mechanism is proposed. A system consisting of a friction latch, constant force spring, rotary damper with rack, and pinion is developed. The retracting drawer can be latched at any position and can be reactivated by simple touch. The constant force spring and rotary damper offer smooth closing action. The ergonomic quality of the closing action is quantified by an index based on velocity-time behavior. The effects of various design parameters are analyzed with a dynamics model and experimentally validated by prototype testing.

The Effect of Lightly Gripping a Cane on Sit-to-stand Transfer in Post-stroke Patients

  • Choi, Young-eun;An, Duk-hyun
    • 한국전문물리치료학회지
    • /
    • 제24권4호
    • /
    • pp.54-59
    • /
    • 2017
  • Background: Light touch cue is a sensory input that could potentially help in the control of posture. The immediate stimulatory effect of light touch cues using a cane during gait is associated with postural stability. This strategy can help post-stroke individuals regain their ability to perform the sit-to-stand (STS) transfer safely. Objects: The effects of light grip on postural control during the STS transfer in post-stroke subjects were investigated. Methods: Eleven participants (6 men, 5 women) with hemiplegia due to stroke were recruited in the study. The subjects with hemiparesis performed STS transfer in three randomly assigned conditions (1) without a cane (2) light grip with a cane (3) strong grip with a cane. Results: The difference in weight-bearing distribution between the left and right feet, when the subjects were instructed to stand up, was $52.73{\pm}2.13%$ without a cane, $42.75{\pm}3.26%$ with a strong grip, and $43.00{\pm}2.55%$ with a light grip (p<.05). The rate of rise in force indicates the peak power provided by subjects during their STS transfers. The rate of rise in force was statistically significantly lower without a cane than that with a light grip or a strong grip (p<.05). The subjects' centers of pressure sway on the mediolateral side during STS transfers statistically significantly declined with a light grip or a strong grip when compared to those without a cane (p<.05). Conclusion: When the subjects with hemiparesis used a cane during STS transfers, their duration, center of pressure sway, and difference in weight-bearing distribution were all reduced. The subjects also exhibited similar results during STS transfers with a cane gripped lightly. This result may provide guidelines for the use of assistive devices when patients with hemiparesis practice STS transfers in clinical settings.

도마 몸 펴 쿠에르보 비틀기 동작 분석 (The Biomechanical Analysis of the Cuervo Salto Forward Straight Vaults with Twists)

  • 임규찬
    • 한국운동역학회지
    • /
    • 제15권4호
    • /
    • pp.143-151
    • /
    • 2005
  • This study was conducted to investigate the technical factors of Cuervo forward straight vaults with single twist, single and half twists, and double twists actually performed by three execellent male gymnasts participated in artistic gymnastics competition of 2003 summer Universiade in Daegu and the 85th National Sports Festival in Cheongju. To accomplish the research goals the Cuervo vaults of three gymnasts were filmed by using three digital camcorders set by 60 Hz, and data were collected through the DLT method of three dimensional cinematography. The kinematic and kinetic variables as each phasic time, CM displacement velocity, release angle inclination angle hip joint angle landing angle, average horse reaction force average moment arm average torque, whoe body's total remote local angular momentum were analyzed, so the following conclusions were reached. Generally to perform the better Cuervo vault, a gymnast should touch down on the board with the great horizontal velocity of the whole body through the fast run-up, and touch down on the horse by decreasing the horizontal displacement of the whole body during the preflight, so raise CM height gradually within a short horse contact time. He should increase the horse reaction force through checking the horizontal velocity of the whole body effectively and the inclination angular displacement of the handstand, if so he can have the large vertical velocity of the whole body. By using the acquired the velocity and the angular momentum of the whole body, he can vault himself higher and twist sufficiently, then he can get better if the body could be tilted by swinging both arms and perform the cat twist with a little flexions at hip joints. According to the above outcomes we can judge that the best athletes is LuBin, the better is YTY, and the next is JSM.

공용 터치 장치를 위한 외골격 유연 구조 (Exo-Skeletal Flexible Structure for Communal Touch Device)

  • 정재윤;이은지;박형률;추원식
    • 적정기술학회지
    • /
    • 제6권2호
    • /
    • pp.219-225
    • /
    • 2020
  • 터치 장비와 스마트 러닝의 중요성이 높아짐에 따라 공공 기관 및 교육시설에서는 스마트 디바이스(smart device)를 업무 및 교육 환경에 적용하는 추세이다. 그러나 공공 스마트 디바이스 사용자들은 직·간접적 감염병 확산에 노출될 위험이 있다. 본 연구는 스마트 디바이스 사용자를 위해 손가락 끝을 감싸는 외골격 장치(Exo-finger)를 개발하였으며, 공용 장비에 활용 시 질병 예방 효과를 가지고자 한다. 활성화 재료인 카본 블랙(Carbon Black, CB)과 고분자 탄성중합체(elastomer)를 혼합한 2차 재료를 금형에 넣어 외골격 장치를 제작하였다. 이 장치는 CB 함량이 0.030 wt.% 이상일 때, 터치 기능이 있는 것으로 확인되었으며 탄성중합체의 함량을 변화시켜 사람이 스마트 디바이스를 터치할 때와 유사한 마찰력(마찰계수 2.5)를 가질 수 있도록 하였다. 실험을 통하여 CB의 함유량은 마찰 계수에 주는 영향이 거의 없음을 확인하였다. 완성된 시제품을 스마트 디바이스에 테스트한 결과, 개발된 외골격 장치는 보호 장구를 착용하여 터치가 불가능한 경우 또는 감염병 확산을 막기 위해 장갑 등의 장비를 사용하는 경우에 유용하게 활용할 수 있음을 확인하였다.