• Title/Summary/Keyword: Force measuring

Search Result 948, Processing Time 0.023 seconds

Study on measuring the low torque on an air tool operating at 100,000 RPM class (100,000 RPM급으로 회전하는 에어공구에서의 저토오크 측정에 관한연구)

  • Kim, Eun-Jong;Cho, Soo-Yong
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2018-2023
    • /
    • 2003
  • An experiment is conducted for measuring the performance of an air tool, which is operated at 100,000 RPM at the unloaded state with the low torque. An experimental apparatus is developed as the power absorption type dynamometer. Inlet static pressure, flow rate, RPM and force are measured simultaneously. Torque, output power and specific output power are obtained. Those experimental results are compared with the experimental results obtained on a commercial dynamometer. However, no commercial dynamometers are available for measuring the torque above 30,000RPM. In order to use the commercial dynamometer, a reduction gear is applied to the shaft of dynamometer. Torque and power obtained on the commercial dynamometer show 50% lower than those obtained on a power absorption type dynamometer, because the inertia force is added to the air tool rotor for the braking system. Moreover, the starting RPM on the commercial dynamometer is less than 40,000RPM. From the compared results, they show that the power absorption type dynamometer should be applied for measuring the performance of an air tool operating at low torque and high RPM.

  • PDF

Ultimate Strength and Design Method of Turn-buckle for Measuring Tensile Force (인장력 측정용 턴버클의 극한강도 및 설계방법)

  • Lee, Swoo Heon;Shin, Kyung Jae;Lee, Hee Du
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.1
    • /
    • pp.61-70
    • /
    • 2013
  • A turn-buckle is capable of adjusting the tensile force by left-hand threads and right-hand threads between tension members. There are different types of turn-buckles according to tension member and connection form but the practical and existing turn-buckles are incapable of measuring the tensile force. A turn-buckle for adjusting and measuring tensile force has therefore been developed. This study shows the ultimate strength and reliability for measurement of the new turn-buckles through finite element analysis of the developed ones. From analytic results of the new turn-buckles which have the measurement limit loads of 100kN, 200kN and 300kN, the ultimate strength is approximately five times stronger than the measurement limit capacity. Additionally, a review of the new turn-buckle, which has the measurement limit load of over 300kN, shows that there is a tendency for the size of turn-buckle to become larger. So the connection devices were designed and the loading test was conducted from the concept that the parallel connection of turn-buckle with 300kN capacity can measure the tensile force of 600kN. The results of parallel loading test show the sufficient possibility. Furthermore, the mock-up test was constructed to investigate the release of initial load and corrosion when the new turn-buckle is installed at the outdoor and exposed to rain and atmosphere.

Investigation on the Students' Abilities of Reading Scales and Conceptions Related with Measuring Instruments and Units (초.중학생의 눈금 읽기 능력 및 측정 도구와 단위에 관련된 개념 조사)

  • Soh, Jong-Ah;Jong, Hee-Kyong;Jung, Yong-Jae
    • Journal of The Korean Association For Science Education
    • /
    • v.20 no.1
    • /
    • pp.1-11
    • /
    • 2000
  • This study investigated both elementary and middle school students' abilities of reading scales and students' conceptions of measuring instruments and units. Seventy two students with 5th grade, sixty nine students with 7th grade, and eighty students with 9th grade were participated. Performance tests and written questionnaires were used. To assess their scale reading abilities, individual performance test was used. Every student should measure length of an envelope, temperature of water, volume of water, etc. And to find out students' conceptions related with measuring instruments and units, written questionnaires with pictures and photographs were used. Some of the students' abilities of reading scales were considerably poor. The results of a two-plate-balance and measuring-cylinder were worse than those of a ruler, a spring-balance, and a thermometer. Many of the students had misconceptions related with measuring instruments. Some of them did not know exactly the meaning of volume, or mass, or force. So they did not know what to measure with the measuring instruments. Also students were confused with several units of volume, force, weight and mass.

  • PDF

The study of force control by using feedback current and encoder signal of the servo-motor on the servo-gun system (서보 모터의 피드백 전류와 위치신호를 이용한 서보건의 가압력 제어에 관한 연구)

  • Lee, Jong-Gu;Kim, Tae-Hyeong;Lee, Se-Heon
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.63-65
    • /
    • 2005
  • Because of simple principal and low cost, resistance spot welding has been used a lot for joining the sheet metal in automotive manufacturing process. Welding current, welding time, and force are the most important variables in resistance spot wording. Air guns have hem still used widely. The requirement of synchronizing between robot and weld-gun has become bigger as the field has been automated. The number of servo-gun in the field is trending upward because there're advantages as like to synchronize with robot and to control the stroke path and force by programming on servo-gun system. But no cleared force control method is suggested on servo-gun system until now. In this study, we proved the feedback current of the servo-motor can be used to an excellent force measuring sensor and the force is controlled by the feedback current. And we also detected force lowering during welding cycle on the servo-gun system and solved by compensated force control.

  • PDF

THE EFFECTS OF MECHANICAL FORCE ON CULTURED PERIODONTAL LIGAMENT CELLS IN VITRO (물리적 외력이 배양중인 치주인대세포에 미치는 영향)

  • Kim, Hyun-young;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.24 no.2
    • /
    • pp.295-301
    • /
    • 1994
  • The movement of teeth during orthodontic treatment requires bone remodeling process in periodontal tissue. To find out the changes occuring in the cell itself, mechanical force was applied to the cultured periodontal ligament cells. Following results were obtained from measuring the changes in cyclic AMP and $PGE_2$, $^3H$-thymidine incorporation amount in time lapse after application of mechanical force. 1. When mechanical force was applied to cultured PDL cells, the amount of cAMP in cells were increased significantly after 15 min. of force application, but were decreased gradually as time lapsed. 2. When mechanical force was applied to cultured PDL cells, the amount of PGE2 were increased at 20,40,60 min. and was significantly increased at 20 min. 3. When mechanical force was applied to cultured PDL cells, the amount of $^3H$-thymidine incorporation was some increased, but was not statistically significant.

  • PDF

Solid Electrochemical Method of Measuring Hydrogen Concentration with O2-/H+ Hetero-Ionic Junction

  • Chongook Park
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.63-69
    • /
    • 2024
  • A novel method for measuring hydrogen concentration is introduced, along with its working principle and a novel detection algorithm. This configuration requires no additional reference compartment for potentiometric electrochemical measurements; therefore, it is the most suitable for measuring dissolved hydrogen in the liquid phase. The sensor's electromotive force saturates at a certain point, depending on the hydrogen concentration during the heating process of the sensor operation. This dynamic temperature scanning method provides higher sensitivity than the constant temperature measurement method.

Development of lntelligent Shoe System to Measure Applied Force/Moment on the Sole of a Foot during Human Walking (사람 보행시 발바닥의 힘정보를 측정하기 위한 지능형 신발시스템 개발)

  • Kim, Gab-Soon;Kim, Hyeon-Min;Hu, Duck-Chan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.7
    • /
    • pp.79-86
    • /
    • 2008
  • This paper describes the development of wearing intelligent shoe system to measure applied forces and moments (ground reaction forces and moments) on the soles of feet during human walking. In order to walk safely, robot must get the intelligent feet with 6-axis force/moment sensors (Fx sensor (x-direction force sensor), Fy sensor, Fz sensor, Mx sensor (Mx : x-direction moment sensor), My sensor, and Mz sensor) and detect the forces and moments data from the sensors. And the feet must be controlled with the data and controllers. While a human is walking, the forces and moments should be measured and analyzed for robot's intelligent feet. Therefore, the wearing intelligent shoe system should be developed. In this paper, four 6-axis farce/moment sensors and two high speed measuring devices were designed and fabricated, and the wearing intelligent shoe system was made using these. The characteristic tests of the wearing intelligent shoe system were performed, and the forces and moments were detected using it.

Design of Force Sensors for the Ankle Rehabilitation Robot of Severe Stroke Patients (중증뇌졸중환자의 발목재활로봇을 위한 힘센서 설계)

  • Kim, Han-Sol;Kim, Gab-Soon
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.148-154
    • /
    • 2016
  • This paper describes the design and fabrication of a two-axis force/torque sensor and an one-axis force sensor with parallel plate beams(PPSs) for measuring forces and torque in an ankle rehabilitation exercise using by a lower rehabilitation robot. The two-axis force/torque sensor is composed of a Fy force sensor and Tz torque sensor and the force sensor detects x direction force. The two-axis force/torque sensor and one-axis force sensor were designed using by FEM(Finite Element Method), and manufactured using strain-gages. The characteristics experiment of the two-axis force/torque sensor and one-axis force sensor were carried out respectively. As a test results, the interference error of the two-axis force/torque sensor was less than 1.56%, the repeatability error and the non-linearity of the two-axis force/torque sensor were less than 0.03% respectively, and the repeatability error and the non-linearity of the one-axis force sensor were less than 0.03% and 0.02% respectively.

The Influence by Stylus Tip Radius and Measuring force on the Stylus Type Surface Roughness Tester (촉침식표면거칠기 측정기에 있어서 촉침의 선단곡률반경과 측정압이 측정에 미치는 영향)

  • Kang, Myung-Soon;Han, Eung-Kyo;Kwon, Dong-Ho;Cho, Nahm-Gyoo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.3 no.1
    • /
    • pp.69-76
    • /
    • 1986
  • The measuring Method by stylus, which measures surface roughness, has been widely used since G. Schmaltz developed the first equipment of that type. Withe the resent development of the measuring method by stylus, surface foughness testing instruments of the very high magnification ratio, hundreds of thousands, are manu- factured. However, as the techniques of the high precision roughness measurement are being required, the response problems due to the tip shapes and the plastic deformations of measured surface of mild material are to be serious factors. In this study, diamond stylus of tip radius $0.5\mu\textrm{m}$, $2\mu\textrm{m}$, $5\mu\textrm{m}$ and $10\mu\textrm{m}$ were used under the measuring force of 0.01gf, 0.02gf, 0.07gf, 0.4gf and 1.6gf, and from the experimental data, maximum measured value devrements between $2\mu\textrm{mR}$ stylus and $5\mu\textrm{mR}$ stylus, $2\mu\textrm{mR}$ stylus and $10\mu\textrm{mR}$ stylus are 22% and 31%, respectively when the measured value of $2\mu\textrm{mR}$ stylus goes to $0.01\mu\textrm{m Ra}$, $\lambda$ c2.5mm. And it is shown that plastic deformations on the plastic deformations on the measured surface are proportional to W/R(W;measured force, R;stylus tip radius).

  • PDF