• Title/Summary/Keyword: Force measurement

Search Result 1,614, Processing Time 0.026 seconds

Detection of Tool Wear using Cutting Force Measurement in Turning (선사가공에 절삭력을 이용한 공구마멸의 감지)

  • 윤재웅;이권용;이수철;최종근
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.1
    • /
    • pp.1-9
    • /
    • 2001
  • The development of flexible automation in the manufacturing industry is concerned with production activities performed by unmanned machining system A major topic relevant to metal-cutting operations is monitoring toll wear, which affects process efficiency and product quality, and implementing automatic toll replacements. In this paper, the measurement of the cutting force components has been found to provide a method for an in-process detection of tool wear. The static com-ponents of cutting force have been used to detect flank wear. To eliminate the influence of variations in cutting conditions, tools, and workpiece materials, the force modeling is performed for various cutting conditions. The normalized force dis-parities are defined in this paper, and the relationships between normalized disparity and flank were are established. Final-ly, artificial neural network is used to learn these relationships and detect tool wear. According to proposed method, the static force components could provide the effective means to detect flank wear for varying cutting conditions in turning operation.

  • PDF

Development of 6-Axis Stiffness Measurement Device for Prosthetic Socket Design (의수 소켓 설계를 위한 6축 인체 탄성도 측정 장치 개발)

  • Oh, Donghoon;Lee, Seulah;Choi, Youngjin
    • The Journal of Korea Robotics Society
    • /
    • v.14 no.1
    • /
    • pp.58-64
    • /
    • 2019
  • The paper proposes a stiffness measurement device composed of a measurement part including six indenters and a fixing part including four fixtures. The device is able to make simultaneously measurements of the stiffness of human arm. The six indenters make use of both position and force control schemes sequentially whenever needed. In addition, the loadcells and the digital encoders are attached to the indenters and electric motors, respectively, so that the data can be provided in real time. On the end of the indenter, two-axis potentiometer is attached in order to measure the angle difference between the applied force axis and the axis normal to the skin of human arm, and to convert the force measured on the loadcell into the actual applied force to skin. For this purpose, the mapping between the voltage output and the angle of potentiometer was obtained by fitting it for each axis. Ultimately, the measurement device was able to measure the stiffnesses of six regions of human arm.

A study on a hot forging process monitoring for measurement of indirect forging force in flange bolt forming of titanium alloys (티타늄 합금 플랜지 볼트 성형에서의 단조력 간접 측정을 위한 열간 단조 공정 모니터링에 관한 연구)

  • Ha, Seok-Jae;Choi, Doo-Sun;Lee, Dong-Won;Song, Ki-Hyeok
    • Design & Manufacturing
    • /
    • v.15 no.1
    • /
    • pp.14-20
    • /
    • 2021
  • The objective of this study is to introduce the new possibility of sensing technology based on inductive displacement sensors to monitor the status of wheel position in the hot forging process. In order to validate effectiveness of proposed sensing technology, the indirect forging force measurement with displacement sensor was applied into a typical closed hot forging die-set used for the manufacturing of flange bolts. The locations to implement the displacement sensor were selected carefully by simulating forming process and static structural. From the measurement results of the forging force change during one hot forging cycle, it was found that the proposed monitoring system can provide useful information to understand the detailed behaviors of die-set in the closed hot forging process.

Image Analysis for the Simultaneous Measurement of Underwater Flow Velocity and Direction (수중 유속 및 유향의 동시 측정을 위한 이미지 분석 기술에 관한 연구)

  • Dongmin Seo;Sangwoo Oh;Sung-Hoon Byun
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.307-312
    • /
    • 2023
  • To measure the flow velocity and direction in the near field of an unmanned underwater vehicle, an optical measurement unit containing an image sensor and a phosphor-integrated pillar that mimics the neuromasts of a fish was constructed. To analyze pillar movement, which changes with fluid flow, fluorescence image analysis was conducted. To analyze the flow velocity, mean force analysis, which could determine the relationship between the light intensity of a fluorescence image and an external force, and length-force analysis, which could determine the distance between the center points of two fluorescence images, were employed. Additionally, angle analysis that can determine the angles at which pixels of a digital image change was selected to analyze the direction of fluid flow. The flow velocity analysis results showed a high correlation of 0.977 between the external force and the light intensity of the fluorescence image, and in the case of direction analysis, omnidirectional movement could be analyzed. Through this study, we confirmed the effectiveness of optical flow sensors equipped with phosphor-integrated pillars.

COMPARISON OF BITE FORCE WITH DENTAL PRESCALE AND UNILATERAL BITE FORCE RECORDER IN HEALTHY SUBJECTS (Dental Prescale과 편측 교합력 측정기를 이용한 정상성인의 교합력 비교)

  • Kwon Ho-Keun;Yoo Ja-Hea;Kwon Young-Sook;Kim Baek-Il
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.103-111
    • /
    • 2006
  • Statement of problem: The previous unilateral bite force recorder has several limitations for taking long time for measuring and causing discomfort to subjects. Because of these reasons, it could not use widely for epidemiological researches. However, 'Dental Prescale System' which is new equipment for measuring bite force, is more convenient for measuring bite force than previous unilateral recorder. Purpose: The purpose of this study was to compare a new technique(Dental Prescale System) using pressure sensitive foils for recording of maximal jaw closing force with conventional measurement using unilateral bite force recorder Material and method: This studies included 22 healthy dental students in college of dentistry Yonsei university in Rep of Korea. Mean age was 23.9 years. All subjects had continuous dental arches and no significant malocclusion or signs from the teeth and craniomandibular system. The Dental Prescale System (Fuji Film, Tokyo, Japan) consists of a horseshoe-shaped pressure sensitive sheet (50H, R type) and a computerized scanning system.(FPD705) We also used unilateral bite force recorder(Denbotics Co. Seoul, Rep.Korea) for comparing with Dental Prescale. Results and conclusion: The total bite force recorded with Dental Prescale System (1423 N) was systematically higher than that recorded by unilateral bite force recorder. (256 N) However, the maximum bite force values measured in the two ways were significantly correlated (r=0.46, p<0.05). The Dental Prescale bite force calculated for first molar (208 N) was lower than that recorded by unilateral bite force recorder. (256 N) The two values were also very significantly correlated. (r=0.66. p<0.001) There were significantly different in bite force between two measurement methods. The reasons were first, unilateral bite force recorder measured only the bite force of a part of teeth, and Dental Prescale measured the total teeth force. Second, in measurement, a difference in muscle contraction appeared by an extent of mouth-opening. Third, unilateral bite force recorder has the reducing effect of the bite force by protective tape. Fourth, Dental Prescale has limitations during the computer scanning procedure. Therefore, Dental Prescale System is considered to be a very promising alternative to be conventional bite force recording methods.

Study on The Suggested Curve Fitting Algorithm for Bolt Clamping Force Measurement (볼트 체결력 측정을 위해 제안한 커브피팅 알고리즘에 관한 연구)

  • Lee, Ki-Won
    • Journal of Satellite, Information and Communications
    • /
    • v.7 no.3
    • /
    • pp.94-98
    • /
    • 2012
  • In order to serve the exact torque clamping force, the torque measurement system use the curve fitting algorithm by the least square. The corrected least square curve fitting algorithm which suggested in this paper can surpport more exact clamping force for fastner in variable industry field using the torque. At first, This paper introduces mathematical modeling for curve fitting algorithm, and simulate it. As a result, the corrected least square algorithm have shown lower standard error value than that of the used algoritm with torque, and so this corrected least square algorithm prove high accuracy than nomal least square algorithm. The suggested algorithm will contribute to improvement of cost and safety on industry field with bolt clamping force for precision industry parts, electronics parts, aircraft, aerospace, etc.

Comparison of Cutting and Compression Tests for the Texture Measurement of Chinese Cabbage Leaves (절단시험과 압착시험에 의한 배추잎의 조직감 측정 비교)

  • Lee, Cherl-Ho;Hwang, In-Ju
    • Korean Journal of Food Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.749-754
    • /
    • 1988
  • The texture measurement of Chinese cabbage leaves used for Kimchi preparation were con ducted by cutting and compression test and the results were compared to the sensory evaluation. The cutting force of cabbage leaf stalk increased by blanching or salting, and a maximum cutting force was attained by salting in 15% salt solution for 5 hours. The compression force and recovered height measured by compression test of Chinese cabbage leaf stalk decreased by blanching or salting, and the breaking point disappeared. Treatment with $CaCl_2$ solution increased the cutting force compression force and breaking strength of fresh leaves, but the effect disappeared by salting or blanching. Cutting strength could be used as a parameter indicating the hardness and chewiness of salted cabbage. Compression force and breaking strength could indicate the textural changes of blanched leaves, but were not useful for the measurement of hardness and chewiness of salted leave.

  • PDF

A large surface-shape measurement method by using Atomic Force Microscope (원자간력 현미경을 이용한 대면적 표면 형상 측정 방법)

  • Shin Y.H.;Ko M.J.;Hong S.W.;Kwon H.K.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1543-1546
    • /
    • 2005
  • This paper presents a method to measure a large surface shape using atomic force microscopy, which has been used mostly for measuring over very tiny surfaces. Experiments are performed to measure a step height and a slope of a test sample. The proposed method is rigorously compared with the coordinate measuring machine. The repetition accuracy and the effects of the set point are also studied. The experimental results show that the proposed method is reliable and should be effective to measure both the nano-accuracy surface profile as well as the micro-accuracy global shape of a macro/micro parts using atomic force microscope.

  • PDF

Friction Force Measurement of Elastohydrodynamic Lubrication with Viscosity Index Improvers (탄성유체윤활 영역에서 점도지수 향상제의 첨가량에 따른 마찰력 측정연구)

  • Kong, Hyun-Sang;Jang, Si-Youl;Park, Kyoung-Kuhn
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.267-271
    • /
    • 2002
  • Most studies of elsatohydrodynamic lubrication are oriented only to the measurement of film thickness itself with optical interferometer. In order to exactly investigate the characteristics of a certain lubricant, it is also important to get the information of traction force as well. In this work, we developed the device for measuring friction force of ehl contact condition together with the film thickness. To verify the validity of the measuring system, the friction force and film thickness under ehl condition are measured with the variation of additive ratios of viscosity index Improvers.

  • PDF