• 제목/요약/키워드: Force calibration

검색결과 157건 처리시간 0.034초

Prussian blue가 전착된 indium tin oxide 전극을 이용한 전기화학적 검출기 (An Electrochemical Detector Using Prussian Blue Electrodeposited Indium Tin Oxide Electrode)

  • 이인제;김주호;강치중;김용상
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권10호
    • /
    • pp.449-452
    • /
    • 2005
  • We fabricated an electrochemical detector (ECD) to catalyze redox reaction efficiently by electrodepositing Prussian blue (PB) on the indium tin oxide (ITO) electrode. Capillary electrophoresis (CE) and amperometric method were used. We investigated the PB surface properties by topography from atomic force microscopy (AFM). Also PB film thickness calibration with respect to deposition time and voltage was used to get better PB surFace. The PB thin film of dense and smooth surface could catalyze redox reaction efficiently. Comparing with CE-ECD microchip using bare-lTO electrode, proposed CE-ECD microchip using PB deposited electrode has shown better sensitivity by determining the detected peak current from the electropherograms while the concentration of tested analyzes was maintained the same. It is verified that detection limit can be lowered for 0.01 mM of dopamine and catechol respectively.

비탄성 설계 스펙트럼에 의한 이력 모델의 효과 (Effect of Hysteretic Models on the Inelastic Design Spectra)

  • 한상환;오영훈;이리형
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.214-224
    • /
    • 1999
  • The design response spectrum has been widely used in seismic design to estimate force and deformation demands of structures imposed by Earthquake Ground Motion (EQGM). Inelastic Design Response Spectra (IDRS) to specify design yielding strength in seismic codes are obtained by reducing the ordinates of Linear Elastic Design Response Spectrum (LEDRS) by strength reduction factor (R). Since a building is designed using reduced design spectrum (IDRS) rather than LEDRS in current seismic design procedures it allows structures behave inelastically during design level EQGM. Inelastic Response Spectra (IRS) depend not only on the characteristics of the expected ground motion at a given site, but also on the dynamic properties and nonlinear characteristics of a structure. However, it has not been explicitly investigated the effect of different hysteretic models on IRS. In this study, the effect of hysteretic models on IRS is investigated.

  • PDF

Analysis of partially embedded beams in two-parameter foundation

  • Akoz, A.Yalcin;Ergun, Hale
    • Structural Engineering and Mechanics
    • /
    • 제42권1호
    • /
    • pp.1-12
    • /
    • 2012
  • In this study, Pasternak foundation model, which is a two parameter foundation model, is used to analyze the behavior of laterally loaded beams embedded in semi-infinite media. Total potential energy variation of the system is written to formulate the problem that yielded the required field equations and the boundary conditions. Shear force discontinuities are exposed within the boundary conditions by variational method and are validated by photo elastic experiments. Exact solution of the deflection of the beam is obtained. Both foundation parameters are obtained by self calibration for this particular problem and loading type in this study. It is shown that, like the first parameter k, the second foundation parameter G also depends not only on the material type but also on the geometry and the loading type of the system. On the other hand, surface deflection of the semi infinite media under singular loading is obtained and another method is proposed to determine the foundation parameters using the solution of this problem.

설압력 측정품구에 관한 연구 (A STUDY OF ELECTRONIC DEVICE FOR THE MEASURING THE TONGUE PRESSURE)

  • 이호용;김기환;정경훈
    • 대한치과의사협회지
    • /
    • 제15권12호
    • /
    • pp.1027-1030
    • /
    • 1977
  • It has been widely believed that the exact measurement of the forces exerted on teeth and its structures by the lingual and perioral musculatures such as lip, cheek and tongue is important and significant in dentistry. Such measuring, moreover, is highly emphasized the importance of the fact that it can be of much help to study the physiological function displayed in the oral cavity. Recognizing the importance of measuring the pressures, the author has devised an electronic device consisting of pressure transducers utilizing reistance-strnain gauges. This electronic strain gauge was very easy to manipulate and its scale error was extremely minimized, unaffected by mouth temperature, mosture and external forces Author was able to read its results with attached meter without using calibration chart. Futhermore, the sensitivity of this electronic device was extremely high, Thus it facilitated to measure a force from 0 to 230 grams.

  • PDF

Electrochemical Signal Amplification by Gap Electrodes and Control of Gap Distances

  • Park, Dae Keun
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권3호
    • /
    • pp.197-200
    • /
    • 2019
  • We report on electrochemical signal amplification using gap electrodes based on the redox cycling between gap electrodes. The distance between electrodes was controlled from $2{\mu}m$ to a few hundreds of nanometer by chemical deposition of reduced Au ion on the pre-defined electrodes. Enhanced redox current of ferri/ferrocyanide was obtained by redox cycling between the two working electrodes. The faradaic current is amplified about a thousand times in this redox system. Since the signal amplification is due to the shortened diffusion length between the two electrodes, the narrower the nanogap was, the better detection limit, calibration sensitivity, and dynamic range. The experimental results were discussed on the basis of the cyclic voltammetry (CV), atomic force microscope (AFM) and scanning electron microscope (SEM) measurements.

A 285-fsrms Integrated Jitter Injection-Locked Ring PLL with Charge-Stored Complementary Switch Injection Technique

  • Kim, Sungwoo;Jang, Sungchun;Cho, Sung-Yong;Choo, Min-Seong;Jeong, Gyu-Seob;Bae, Woorham;Jeong, Deog-Kyoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권6호
    • /
    • pp.860-866
    • /
    • 2016
  • An injection-locked ring phase-locked loop (ILRPLL) using a charge-stored complementary switch (CSCS) injection technique is described in this paper. The ILRPLL exhibits a wider lock range compared to other conventional ILRPLLs, owing to the improvement of the injection effect by the proposed CSCS. A frequency calibration loop and a device mismatch calibration loop force the frequency error to be zero to minimize jitter and reference spur. The prototype chip fabricated in 65-nm CMOS technology achieves a $285-fs_{rms}$ integrated jitter at GHz from the reference clock of 52 MHz while consuming 7.16 mW. The figure-of-merit of the ILRPLL is -242.4 dB.

분동식압력계를 이용한 저진공게이지의 평가 (Evaluation of low vacuum gauge using deadweight piston gauge)

  • 우삼용;최인묵;송한욱;김부식
    • 한국진공학회지
    • /
    • 제16권4호
    • /
    • pp.244-249
    • /
    • 2007
  • 분동식압력계는 정밀한 압력 측정의 기준 장비로 널리 사용되고 있다. 그것은 분동압력계가 견고하고 정확하며 이동이 간편하고 압력의 정의를 물리적으로 구현할 수 있기 때문이다. 기본적으로 분동식압력계는 분동과 피스톤/실린더 장치로 구성되며 실린더 안에 직경이 꼭 맞는 피스톤이 수직으로 삽입된 구조를 갖고 있다. 측정하려는 압력은 피스톤 아래에 작용하여 윗방향 힘을 발생시키고 피스톤 위에 얹혀 있는 분동에 의해 발생하는 아랫방향 힘과 평형을 이루게 된다. 이때 피스톤 자체의 하중은 항상 작용하므로 분동식압력계는 보통 10 kPa이상의 압력 범위에서 주로 사용된다. 기존의 방식은 피스톤 아래의 높은 압력을 기준으로 사용하지만 본 방식은 피스톤 주위의 낮은 압력을 기준압력으로 사용하여 보다 더 낮은 압력의 측정이 가능하다. 본 논문에서는 이를 효율적으로 구현한 새로운 장치를 소개하고 실제로 1.33 kPa, 13.3 kPa 두 측정범위를 갖는 정밀한 저진공 게이지(MKS, CDG)를 교정, 평가한 결과에 대해서 기술하였다.

원위치 관입실험기를 활용한 철도 노반 평가 (Railbed Evaluation by using In-situ Penetration Test)

  • 김주한;박정희;윤형구;고태훈;이종섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.261-267
    • /
    • 2011
  • The test fit has commonly used for the evaluation of the railbed condition, and indirect methods by using the compressional wave are also studied. the direct evaluation method by penetration test has not been studied. For the measurement of in-situ cone tip resistance of the railbed with minimizing the disturbance of the upper railbed. the cone penetrometer with the helical type outer rod(CPH) was developed. The outer rod, which has helical screw, is penetrated through the gravel layer and provides the reaction force for cone penetration testing. the cone tip resistances are measured by the mini cone penetrometer, where diameter is 15mm. For the developing the mini cone, strain gauge installation, circuit configuration, penetration rates and calibration process are considered. For the easy penetration of the screw rod in the field, the reaction force stepping plate and guide column are arranged. The screw rod are penetrated through the gravel layer. And the mini cone was pushed into the subgrade railbed at the penetration rate of 1mm/sec. The penetration test shows that the cone tip resistance increases along the depth. In addition, the subgrade condition is evaluated. This study demonstrates that the CPH may be effectively used for the evaluation of subgrade method any damage of the gravel layer.

  • PDF

A Miniature Humanoid Robot That Can Play Soccor

  • Lim, Seon-Ho;Cho, Jeong-San;Sung, Young-Whee;Yi, Soo-Yeong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.628-632
    • /
    • 2003
  • An intelligent miniature humanoid robot system is designed and implemented as a platform for researching walking algorithm. The robot system consists of a mechanical robot body, a control system, a sensor system, and a human interface system. The robot has 6 dofs per leg, 3 dofs per arm, and 2 dofs for a neck, so it has total of 20 dofs to have dexterous motion capability. For the control system, a supervisory controller runs on a remote host computer to plan high level robot actions based on the vision sensor data, a main controller implemented with a DSP chip generates walking trajectories for the robot to perform the commanded action, and an auxiliary controller implemented with an FPGA chip controls 20 actuators. The robot has three types of sensors. A two-axis acceleration sensor and eight force sensing resistors for acquiring information on walking status of the robot, and a color CCD camera for acquiring information on the surroundings. As an example of an intelligent robot action, some experiments on playing soccer are performed.

  • PDF

보정된 부가질량을 이용한 댐 수문의 지진해석 (Earthquake Analysis of Dam Floodgate Using Calibrated Added Mass)

  • 배정주;김호승;김용곤;이지호
    • 한국지진공학회논문집
    • /
    • 제13권5호
    • /
    • pp.31-40
    • /
    • 2009
  • 본 논문에서는 현장 강제진동실험에서 측정된 수문의 고유진동수를 수치 시뮬레이션을 통해 얻은 대응 값과 비교하는 과정을 반복하여 수문의 부가질량을 보정하는 방법을 설명하였다. 보정된 부가질량이 수문의 내진성능평가에 미치는 영향을 평가하기 위하여 현장 강제진동실험이 행해진 수문을 대상으로 지진해석을 수행하였으며, Westergaard 부가질량을 사용한 수문의 수치모형이 실측 자료로 보정된 부가질량을 사용한 경우보다 최대 지진력과 최대 변위에서 상대적으로 큰 값을 산출하는 결과를 보여주었다.