• 제목/요약/키워드: Force application angle

Search Result 105, Processing Time 0.025 seconds

Development of Metallic Bipolar Plate for Automotive PEMFC (자동차 구동용 PEMFC 금속계 분리판 개발)

  • Jeon, Yoo-Taek;Chung, Kyeong-Woo;Na, Sang-Mook
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.321-325
    • /
    • 2005
  • Bipolar plate is the main part with MEA in automotive PEMFC. It must have a good electrical conductivity and excellent corrosion resistance, be cost effective. Therefore, stainless steels have been studied by many researchers because of its corrosion resistance and cost benefits. But their properties are not sufficient for the application to bipolar plate for automotive PEMFC. In this work, we have performed stamping using various commercial stainless steels to select candidate material for biploar plate and to derive design parameters for stamping simulation. The results showed that a small curvature at the corner of flow field is more favorable due to easier a plastic deformation. Stamping process was simulated by changing surface condition, and the size and angle of channel. The optimum shape and spring back phenomena were evaluated. Surface coating was applied to increase the corrosion resistance and electrical conductivity of stainless steel. The electrical interfacial resistance was 10 to $15m{\Omega}cm^2$ under clamping force of 150psi. But corrosion resistance of coating on the stainless steel was not good due to the unstableness of microstructure.

  • PDF

Optimization of Cleaning Parameters in Cryogenic $CO_2$ Cleaning Process (극저온 $CO_2$ 세정공정의 세정인자 최적화)

  • Lee, Seong-Hoon;Seok, Jong-Won;Kim, Pil-Kee;Oh, Seung-Hee;Seok, Jong-Hyuk;Oh, Byung-Joon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.9
    • /
    • pp.109-115
    • /
    • 2008
  • The cleaning process of contaminant particles adhering to the microchips, integrated circuits (ICs) or the like is essential in modern microelectronics industry. In the cleaning process particularly working with the application of inert gases, the removal of contaminant particles of submicron scale is very difficult because the particles are prone to reside inside the boundary layer of the working fluid, The use of cryogenic $CO_2$ cleaning method is increasing rapidly as an alternative to solve this problem. In contrast to the merits of high efficiency of this process in the removal of minute particles compared to the others, even fundamental parametric studies for the optimal process design in this cleaning process are hardly done up to date, In this study, we attempted to measure the cleaning efficiency with the variations of some principal parameters such as mass flow rate, injection distance and angle, and tried to draw out optimal cleaning conditions by measuring and evaluating an effective cleaning width called $d_{50}$.

Characteristics of Vortical Jet Structures of a Hydrofoil

  • Yang, Chang-Jo;Kim, You-Taek;Choi, Min-Seon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.7
    • /
    • pp.842-851
    • /
    • 2007
  • Oscillating foil propulsion, the engineering application of fish-like movement of a hydrofoil, has received in recent decades as a possible competitor for propellers. The oscillating foil produces an effective angle of attack, resulting in a normal force vector with thrust and lift components, and it can be expected to be a new highly effective propulsion system. We have explored propulsion hydrodynamics as a concept in wake flow pattern. The present study has been examined various conditions such as oscillating frequencies and amplitudes in NACA0010 profile. Flow visualizations showed that high thrust was associated with the generation of moderately strong vortices, which subsequently combine with trailing-edge vorticity leading to the formation of a reverse $K\acute{a}rm\acute{a}n$ vortex street. Vortex generation was inherent to jet production and playeda fundamental role in the wake dynamics. And it was shown that the strong thrust coefficient obtained as the Strouhal number was larger.

Application of Flow Control Devices for Smart Unmanned Aerial Vehicle (SUAV) (스마트무인기에 적용한 유동제어 장치)

  • Chung, Jin-Deog;Hong, Dan-Bi
    • Aerospace Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.197-206
    • /
    • 2009
  • To improve the aerodynamic efficiency of Smart Unmanned Aerial Vehicle (SUAV), vortex generators and flow fence are applied on the surface and the tip of wing. The initially applied vortex generator increased maximum lift coefficient and delayed the stall angle while it produced excessive increase in drag coefficient. It turns out reduction of the airplane's the lift/drag ratio. The new vortex generators with L-shape and two different height, 3mm and 5mm, were used to TR-S4 configuration to maintain the desired level of maximum lift coefficient and drag coefficient. Flow fence was also applied at the end of both wing tip to reduce the interaction between nacelle and wing when nacelle tilting angles are large enough and produce flow separation. To examine the effect of flow fence, flow visualization and force and moment measurements were done. The variation of the aerodynamic characteristics of SUAV after applying flow control devices are summarized.

  • PDF

Nano-scale Probe Fabrication Using Self-assembly Technique and Application to Detection of Escherichia coli O157:H7

  • Oh, Byung-Keun;Lee, Woochang;Lee, Won-Hong;Park, Jeong-Woo
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.8 no.4
    • /
    • pp.227-232
    • /
    • 2003
  • A self-assembled monolayer of protein G was fabricated to develop an immunosensor based on surface plasmon resonance (SPR), thereby improving the performance of the antibodybased biosensor through immobilizing the antibody molecules (lgG). As such, 11-mercaptoundecanoic acid (11-MUA) was adsorbed on a gold (Au) support, while the non-reactive hydrophilic surface was changed through substituting the carboxylic acid group (-COOH) in the 11-MUA molecule using 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrocholide (EDAC). The formation of the self-assembled protein G layer on the Au substrate and binding of the antibody and antigen were investigated using SPR spectroscopy, while the surface topographies of the fabricated thin films were analyzed using atomic force microscopy (AFM). A fabricated monoclonal antibody (Mab) layer was applied for detecting E. coli O157:H7. As a result, a linear relationship was achieved between the pathogen concentration and the SPR angle shift, plus the detection limit was enhanced up to 10$^2$ CFU/mL.

Natural Frequencies of Laminated Composite Plates Attached Point Mass Under an Uniform Axial-Loading (등분포 축하중을 받고 첨가질량이 재하된 적충복합판의 고유진동수)

  • Park, Jae-Sean;Hong, Chang-Woo;Lee, Jung-Ho;Lee, Joo-Hyung
    • Journal of Industrial Technology
    • /
    • v.19
    • /
    • pp.235-243
    • /
    • 1999
  • Vibration analysis for some of simple supported antisymmetric composite laminated plate loaded uniformly distributed axial force and attached mass was carried out. Because it is complicated to analysis this type of plate by theory of antisymmetric laminate, possibility for application of theory of special orthotropic laminate was studied, and natural frequency of laminated plate attached mass was calculated. Stiffness $B_{16}$, $B_{26}$, $D_{16}$, $D_{26}$ for this type of antisymmetric laminated plate converge on zero as the number of ply increases and it is possible to use classical theory by reason that considered plate has quasi-homogeneity without relevance to variation of angle. Difference between results by theory of antisymmetric and special orthotropic laminate is 0.36~1.96%, therefore it is convenient to analyze this by use of theory of special orthotropic laminate. When composite laminated plate with attached mass is analyzed range that was able to neglect self-weight of plate was proposed.

  • PDF

Machining Technology of pinnacle Cutter Edge for Flexible Sheet Die (필름시트 절단용 다이의 절인 가공 기초연구)

  • Je T.J.;Choi D.S.;Whang K.H.;Lee E.S.;Hong S.M.;Choi J.S.;Song B.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.19-20
    • /
    • 2006
  • As the Mobile and Display technology are being developed quickly, new wireless devices are released in great numbers. They reduce existing devices' life time and demand a reduction of developing period of portable devices. With these demands, existing film cutting mold used many films of portable devices, especially LCD Display, needs to be more precise, and cheaper. In this research, we have analyzed machining characteristics of cutter shapes, materials, and cutting conditions for application to other films. Cutter edge was machined by slot cutting method and CAD program to select the cutter shape and cutter angle. Also, we have determined the optimal cutting conditions using high speed machining experiments to improve the productivity.

  • PDF

Finite Element Analysis of Supporting Bone according to Custom Abutment Angles (맞춤형 지대주 각도에 따른 지지골의 유한요소 분석)

  • Nam, Min-Gyeong;Kim, Nam-Sic
    • Journal of Technologic Dentistry
    • /
    • v.37 no.3
    • /
    • pp.115-120
    • /
    • 2015
  • Purpose: The purpose of this study is a finite element analysis of supporting bone according to custom abutment angle. Methods: Implant fixture was selected with a diameter of 4 mm and the length of 13 mm. The fixture and abutment was designed by a combination of the abutment screw clamping force to produce a custom abutment model of $0^{\circ}$, $15^{\circ}$, $25^{\circ}$ and $35^{\circ}$. The loading condition of 176 N was applied to the lingual surface of the crown, near to the incisor edge, and horizontal load. An oblique load of $90^{\circ}$ was applied long axis of the implant fixture analyze the stress of supporting bone. Results: The result of mechanical analysis was observed that the supporting bone stress analysis of the horizontal load, the von Mises stress values (MPa) are given in the order of TH00 (432.6) > TH25 (418.0) > TH15 (417.4) > TH35 (415.8), the oblique load, the von Mises stress values are given in the order of TO00 (459.3) > TO15 (399.6) > TO25 (374.8) > TO35 (343.4) Conclusion: The $35^{\circ}$ abutment over the current clinical tolerance limits will be available for clinical application.

Fabrication of Hydrophilic Poly(dimethylsiloxane)with Periodic Wrinkling Surface and Its Application (일정한 주름을 갖는 친수성 PDMS 제작 및 응용)

  • Lee, Dong-Guk;Oh, Chang-Kyu;Yang, Sung-Ho;Han, Seung-Jin;Jeong, Ok-Chan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.5
    • /
    • pp.671-675
    • /
    • 2014
  • This paper presents a fabrication of hydrophilic Poly(dimethylsiloxane) (PDMS) with periodic wrinkling surface. The proposed periodic wrinkling surface was fabricated using the sequential processes of typical curing process of PDMS, cutting process, platinum deposition process, and wrinkling transfer process. The surface morphology of the fabricated wrinkling surface was observed by using optical and dynamic atomic force microscopy and discussed. The measured period and amplitude of wrinkling was about $2.2{\mu}m$ and $0.31{\mu}m$, respectively. And, the contact angles of water droplets on the wrinkled surface were measured in order to understand effect of the wrinkling surface on surface modification of hydrophobic PDMS. Our new finding was that the proposed wrinkling surface was hydrophilic and the measured contact angle was about $62^{\circ}$. Moreover, it was found out from the simple cell culture test that the fabricated wrinkling surface was more effective for cell spreading and adhesion than the case of native PDMS substrate.

Improved performance of polyamide nanofiltration membranes by incorporating reduced glutathione during interfacial polymerization

  • Jiao, Zhiwei;Zhou, Linjie;Wu, Mengyuan;Gao, Kang;Su, Yanlei;Jiang, Zhongyi
    • Korean Journal of Chemical Engineering
    • /
    • v.35 no.12
    • /
    • pp.2487-2495
    • /
    • 2018
  • Inspired by the specific amino acid sequence Asn-Pro-Ala (NPA) of water channel aquaporins (AQPs), we fabricated polyamide (PA) nanofiltration (NF) membranes by introducing reduced glutathione (GSH) in interfacial polymerization (IP) method. Fourier transform infrared spectroscopy (ATR-FTIR), X-ray photoelectron spectrometry (XPS), scanning electron microscope (SEM), atomic force microscopy (AFM), zeta potential and static water contact angle measurement were employed to characterize the chemical composition, morphology, electronegativity and hydrophilicity of the NF membranes. The water flux of GSH/PIP-TMC NF membrane reached $32.00L\;m^{-2}h^{-1}$ at 0.2 MPa, which was approximately twice than that of pristine PIP-TMC NF membrane when the ratio of GHS to piperazidine (PIP) was 40% during IP process. More water channels were built as GSH was embedded into PA layer. The fabricated NF membranes also took on potent rejection for dyes and $Na_2SO_4$. This study presents a simple and facile method to simulate water channels-based biological materials which may find potential application in water treatment.