• Title/Summary/Keyword: Force Sensitive Resistor

Search Result 11, Processing Time 0.025 seconds

Implementation of Gait Pattern Monitoring System Using FSR(Force Sensitive Resistor) Sensor (압력 센서를 이용한 보행 패턴 모니터링 시스템 구현)

  • Kim, Kiwan
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.2
    • /
    • pp.56-60
    • /
    • 2021
  • Recently, technologies for internet of things have been rapidly advanced with development of network. Also interest in smart healthcare that informs about motion information of users has been growing. In this paper, a system that is monitoring the weight on both feet by using aduino and FSR(Force Sensitive Resistor) Sensor is implemented. A 4-channel sensor driver module was implemented to measure a more accurate weight value. It is monitoring the weight on both feet by the using an application for either your PC or mobile device. Mobile applications can contribute to reducing human damage by sending messages along with location in emergency situations, such as injuries caused by falls during outdoor activities.

Comparison of Maximum Fingertip Force Distribution in Cylindrical Grasping Between Healthy Adults and Patients With Spinal Cord Injury (원통형 물체 쥐기 시 건강한 성인과 척수마비 환자의 최대 손가락 끝 힘 분포 비교)

  • Hwang, Jisun;Ree, Jae Sun;Hwang, Seonhong
    • Physical Therapy Korea
    • /
    • v.29 no.1
    • /
    • pp.28-36
    • /
    • 2022
  • Background: It is known that hand strength and fingertip force are used as an indicator of muscle strength and are also highly related to the various chronic symptoms and even lifespan. To use the individual fingertip force (IFF) as a quantitative index for clinical evaluation, the IFF should be measured and analyzed with various variables from various subjects, such as the normal range of fingertip force and the difference in its distribution by disease. Objects: We tried to measure and analyze the mean maximum IFF distribution during grasping a cylindrical object in healthy adults and patients with spinal cord injury (SCI). Methods: Five Force-sensitive resistor (FSR) sensors were attached to the fingertips of 24 healthy people and 13 patients with SCI. They were asked to grip the object three times for five seconds with their maximum effort. Results: The mean maximum IFF of the healthy adult group's thumb, index, and middle finger was similar statistically and showed relatively larger than IFF of the ring and small finger. It is a 3-point pinch grip pattern. All fingertip forces of patients with SCI decreased by more than 50% to the healthy group, and their IFF of the middle finger was relatively the largest among the five fingertip forces. The cervical level injured SCI patients showed significantly decreased IFFs compared to thoracic level injured SCI patients. Conclusion: We expect that this study results would be helpful for rehabilitation diagnosis and therapy goal decision with robust further study.

Development of Low-cost 3D Printing Bi-axial Pressure Sensor (저가형 3D프린팅 2축 압력 센서 개발)

  • Choi, Heonsoo;Yeo, Joonseong;Seong, Jihun;Choi, Hyunjin
    • The Journal of Korea Robotics Society
    • /
    • v.17 no.2
    • /
    • pp.152-158
    • /
    • 2022
  • As various mobile robots and manipulator robots have been commercialized, robots that can be used by individuals in their daily life have begun to appear. With the development of robots that support daily life, the interaction between robots and humans is becoming more important. Manipulator robots that support daily life must perform tasks such as pressing buttons or picking up objects safely. In many cases, this requires expensive multi-axis force/torque sensors to measure the interaction. In this study, we introduce a low-cost two-axis pressure sensor that can be applied to manipulators for education or research. The proposed system used three force sensitive resistor (FSR) sensors and the structure was fabricated by 3D printing. An experimental device using a load cell was constructed to measure the biaxial pressure. The manufactured prototype was able to distinguish the +-x-axis and the +-y-axis pressures.

An instrumented Glove for Grasp specification in virtual reality based point-and-direct telerobotics

  • Yun, Myung-Hwan;Cannon, David;Freivalds, Andris
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1996.04a
    • /
    • pp.141-146
    • /
    • 1996
  • Hand posture and force, which define aspects of the way an object is grasped, are features of robotics manipulation. A means for specifying these grasping "flavors" has been developed that uses an instrumented glove equipped with joint and force sensors. The new grasp specification system is being used at the Pennsylvania State University (Penn State) in a Virtual Reality based Point-and-Direct(VR-PAD) robotics implementation. In the Computer Integrated Manufacturing (CIM) Laboratory at Penn State, hand posture and force data were collected for manipulating bricks and other items that require varying amounts of force at multiple pressure points. The feasibility of measuring desired grasp characteristics was demonstrated for a modified Cyberglove impregnated with FSR (Force Sensitive Resistor) pressure sensors in the fingertips. A joint/force model relating the parameters of finger articulation and pressure to various lifting tasks was validated for the instrumented "wired" glove. Operators using such a modified glove may ultimately be able to configure robot grasping tasks in environments involving hazardous waste remediation, flexible manufacturing, space operations and other flexible robotics applications. In each case, the VR-PAD approach improved the computational and delay problems of real-time multiple-degree-of-freedom force feedback telemanipulation.ck telemanipulation.

  • PDF

An instrumented glove for grasp specification in virtual reality based point-and-direct telerobotics

  • Yun, Myung Hwan;Cannon, David;Freivalds, Andris
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.165-176
    • /
    • 1996
  • Hand posture and force, which define aspects of the way an object is grasped, are features of robotic manipulation. A means for specifying these grasping "flavors" has been developed that uses an instrumented glove equipped with joint and force sensors. The new grasp specification system is being used at the Pennsylvania State University (Penn State) in a Virtual Reality based Point-and-Direct (VR-PAD) robotics implementation. In the Computer Integrated Manufacturing (CIM) Laboratory at Penn State, hand posture and force data were collected for manipulating bricks and other items that require varying amounts of force at multiple pressure points. The feasibility of measuring desired grasp characteristics was demonstrated for a modified Cyberglove impregnated with FSR (Force Sensitive Resistor) pressure sensors in the fingertips. A joint/force model relating the parameters of finger articulation and pressure to various lifting tasks was validated for the instrumented "wired" glove. Operators using such a modified glove may ultimately be able to configure robot grasping tasks in environments involving hazardous waste remediation, flexible manufactruing, space operations and other flexible robotics applications. In each case, the VR-PAD approach improved the computational and delay problems of real-time multiple- degree-of-freedom force feedback telemanipulation.

  • PDF

Posture correction system based on the Push Service (Push Service 기반의 자세교정 시스템)

  • Lee, Se-Hoon;Jeong, Ui-Jung;Kim, Pung-Il;Lee, Yun-Su
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2017.01a
    • /
    • pp.141-142
    • /
    • 2017
  • 기존의 상용화된 인체공학적 자세교정 의자나 의학적 치료 솔루션은 상대적으로 고가이며 사용자친화적인 접근성을 제공하기 어려웠다. 본 논문에서는 이 문제점을 해결하기 위해 소형 방석에 압력 센서를 접목하고 사용자에게 교정 상태를 상기시키는 시스템을 연구하고 이를 더 사용자 접근성이 좋은 방식을 고안하고자 한다. PushBullet[1] API를 사용하여 Non-Client Application 중심의 Multi-Device 기반 Push notification 기능을 연구하고 이와 기존의 바른 앉은 자세를 유지하는 자세교정 시스템을 결합한 방식을 제안한다.

  • PDF

Design and Development of Posture Correction Chair System Based on Force Sensitive Resistor (압력센서 기반 자세 교정 의자의 설계 및 시스템 개발)

  • Ji-Hyun Jang;Song-Ha Jo;Eun-Kyeung Cho;Chae-Rin Yu;Eun-Seo Lee
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2023.11a
    • /
    • pp.143-144
    • /
    • 2023
  • 일반인은 잘못된 자세를 곧잘 인식하지 못하고 관절에 악영향을 주기 쉽다. 이는 발병으로 이어질 가능성이 있기에, 이를 예방하고자 본 연구에서는 자세 교정 의자 시스템을 제안한다. 해당 시스템은 압력센서로 수집한 데이터를 애플리케이션으로 통신하여, 애플리케이션을 통해 사용자의 자세에 대한 피드백을 제공한다. 또한, 자세와 통증에 대한 통계로 사용자의 자세 교정 및 자가 진단을 돕는다.

Respiration Measurement Sleeping Pillow System (호흡 측정 수면베개 시스템)

  • Ahn, Dohyun;Minh, Tran;Lee, Jongmin;Park, Jaehee
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.280-285
    • /
    • 2017
  • This paper presents a respiration measurement sleeping pillow based on pressure sensors. The respiration measurement sleeping pillow system consists of a sleeping pillow, an interface circuit, a respiration measurement system, and four force-sensitive resistor(FSR) sensors attached at the bottom of the sleeping pillow. The FSR sensors are used to detect the respiration signals induced by the body movement while breathing. The respiration signals of a twenty health man were measured and analyzed by utilizing the respiration measurement sleeping pillow system. The pillow system could detect the respiration signals and had similar characteristics to the chest type BIOPAC respiration sensor used by medical doctors. The respiration rates of ten subjects were also measured. The average measurement accuracy was about 98.8%. The research results showed that this pillow system can be used to detect and analyze the respiration signal when sleeping for the better sleep management.

A Study on the Cost-Effective Personalized Plantar Pressure Measurement System

  • Kang, Ji-Woo;Kwon, Young-Man;Lim, Meoung-Jae;Chung, Dong-Kun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.11 no.4
    • /
    • pp.11-17
    • /
    • 2019
  • Plantar pressure data can be used not only for walking patterns in daily life, but also for eating, health care, and disease prevention. For this reason, the importance of plantar pressure measurement has recently increased. However, most systems that can measure both static and dynamic plantar pressure at the same time are expensive, not portable, and not universal. In this study, we propose a system that effectively reduces the number of sensors in plantar pressure system. Through this, we want to increase the economics and practicality by reducing the size and weight of the system, as well as the power consumption. First, for static plantar pressure and dynamic plantar pressure, the values measured by existing precision instruments are analyzed to determine how many measurement parts the insole is divided into. Next, for the divided measuring parts, the position of the sensor is determined by calculating the Center of Pressure (COP) for each part with the values of all dynamic and static plantar pressure sensors. Finally, in order to construct a personalized plantar pressure measurement system, we propose a weighting method for the static plantar pressure COP and the dynamic plantar pressure COP for each part.