• Title/Summary/Keyword: Force Actuator

Search Result 830, Processing Time 0.031 seconds

Design of a Linear Ultrasonic Actuator for Small Lens Actuation (초소형 렌즈 구동을 위한 선형 초음파 구동기 설계)

  • Kwon, Tae-Seong;Choi, Yo-Han;Lee, Seung-Yop
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.4
    • /
    • pp.251-256
    • /
    • 2006
  • There is a great demand of micro-actuators for mobile information devices such as SFF optical drives and mobile phone cameras. However, the magnetic coils used in conventional electromagnetic motors are a major obstacle for the miniaturization because of their complicated structures and large power consumption. In this paper, a linear ultrasonic motor to actuate focusing lens of mobile devices is proposed. The new actuator uses a ring type bimorph piezoelectric material, and $d_{31}$ mode is adopted for applying linear motion. The interaction between inertia force and friction force makes linear motion by high-frequency saw signal input. The saw signal gives steady forces on the one direction by asymmetric inclination property of the signal itself on time domain. A commercial FEM(ANSYS) was used in this investigation for simulating structural analysis, identification of dynamic property, such as resultant displacement and coupled analysis with piezoelectric material. To evaluate the performance of the new design, a prototype was manufactured and experiments were carried out. Experimental results show the actuator motion of 5.4 mm/s at 10V saw signal of 41 kHz.

  • PDF

Movement characteristics of pneumatic actuators for the semi-autonomous colonoscopic system (자율이동 대장 내시경을 위한 공압구동기의 이동 특성)

  • Kim, Byung-Kyu;Lee, Jin-Hee;Park, Ji-Sang;Lim, Young-Mo;Park, Jong-Oh;Kim, Soo-Hyun;Hong, Yeh-Sun
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.295-300
    • /
    • 2001
  • In recent years, as changing the habit of eating, the pathology in the colon grows up annually. For that reason, the colonoscopy is generalized. But it requires much time to acquire a dexterous skill to perform an operation. And the procedure is painful to the patient. Therefore, biomedical and robotic researchers are developing a locomotive colonoscope that can travel safely in colon. In this paper, we propose a novel design and concept of semi-autonomous colonoscope and two actuators for the micro robot. The micro robot comprises camera and LED for diagnosis, steering system to pass through the loop, pneumatic actuator and bow-shaped flexible supporters to control a contact force and to keep the space between colon wall and the actuator. For actuating mechanism, we suggest two models. One is based on the reaction force, and the other is impact force. In order to validate the concept and the performance of the actuators, we carried out the preliminary experiments in rigid pipes.

  • PDF

Design of the Proprioceptive Actuator Capable of Simultaneous Bidirectional Driving (양방향 동시 구동이 가능한 고유수용성 구동기의 설계)

  • Park, Hui-Chang;Cho, Yong-Jun;Yun, Hae-Yong;Oh, Jang-Seok;Hong, Hyung-Gil;Kang, Min-Su;Park, Kwan-Hyung;Song, Jae-Bok
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.9
    • /
    • pp.98-104
    • /
    • 2022
  • Because a robot actuator is directly affected by the external force of the robot and accounts for the largest portion of the robot system weight, developing an optimized actuator suitable for each characteristic of the robot system is essential. Although there have been many developments and studies related to robot actuators in various industrial fields, lightweight and compact actuator designs that can control force are still lacking. In this study, a novel actuator module was developed, and its performance was verified experimentally. The structure and control of various robot systems can be optimized by utilizing the proposed actuator. It can be used for various tasks by sensing external force and through feedback control.

The Design and Performance Test of Tracking Actuator for NFR system (근접장 기록 장치를 위한 트랙킹 구동기의 설계 및 실험)

  • Kim, Gi-Hyeon;Lee, Mun-Gu;Gwon, Dae-Gap
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.8
    • /
    • pp.174-181
    • /
    • 2001
  • Nowadays, the improvement and development of Multi-media and information & communication technology is rapidly processed. They need large data storage capacity. So that, many studies and researches in data storage have been carried out. According to them, the data storage capacity has been increased. But the limitation of storage capacity is happened for several problems. One of them is spot & pit size in optical and magnetic data storage and another is the resolution of actuators. The problems in spot & pit size are covered by new data storage methods-- for examples, AFM(Atomic Force Microscopy), MO(Magneto-optical) system, and NFR(Near-Field decoding) system etc. But the resolution limit of an actuator was not developed and doesn\`t follow up the development of spot & pit size. Because of them, we should improve a resolution of an actuator. Especially, in this paper an actuator if studied and designed for NFR (in using SIL(Solid Immersion Lens) system. It is a dual stage actuator, which consists of a Fine actuator and a Coarse actuator. and should desire 100nm accuracy. Its actuating force generation method is VCM(Voice Coil Motor). The Fine actuator is composed of 4-leaf springs and a bobbin wrapped by coil. The Coarse actuator has Coils and 3-Roller bearings. Also, The Characteristics of designed actuator for NFR system is estimated by Sine-Swept mode and LDV(Laser Doppler Vibro-meter).

  • PDF

Parameter design optimization of solenoid type magnetic actuator using response surface methodology (반응표면법을 이용한 솔레노이드형 자기액추에이터의 치수 최적화 설계)

  • Soh, Hyun-Jun;Yoo, Jeong-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.579-584
    • /
    • 2003
  • Solenoid type magnetic actuator is the device, which could translate the electromagnetic energy to mechanical force. The force generated by magnetic flux, could be calculated by Maxwell stress tensor method. Maxwell stress tensor method is influenced by the magnetic flux path. Thus, magnetic force could be improved by modification of the iron case, which is the route of the magnetic flux. Modified design is obtained by parameter optimization using by Response surface methodology.

  • PDF

Force Tracking Control of a Smart Flexible Gripper Featuring Piezoceramic Actuators (압전 세라믹 작동기로 구성된 스마트 유연 그리퍼의 힘 추적 제어)

  • Choi, Seung-Bok;Cheong, Chae-Cheon;Lee, Chul-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.1
    • /
    • pp.174-184
    • /
    • 1997
  • This paper presents a robust force tracking control of a smart flexible gripper featured by a piezoceramic actuator characterizing its durability and quick response time. A mathematical governing equation for the proposed gripper structure is derived by employing Hamilton's principle and a state space control model is subsequently obtained through model analysis. Uncertain system parameters such as frequency variation are included in the control model. A sliding mode control theory which has inherent robustness to the sys- tem uncertainties is adopted to design a force tracking controller for the piezoceramic actuator. Using out- put information from the tip force sensor, a full-order observer is constructed to estimate state variables of the system. Force tracking performances for desired trajectories represented by sinusoidal and step func- tions are evaluated by undertaking both simulation and experimental works. In addition, in order to illustrate practical feasibility of the proposed method, a two-fingered gripper is constructed and its performance is demonstrated by showing a capability of holding an object.

  • PDF

Computer Simulation and Control performance evaluation of Ultra Precision Positioning Apparatus using Piezo Actuator (Piezo Actuator를 이용한 초정밀 위치결정기구의 Computer Simulation 및 제어 성능평가)

  • 김재열;김영석;곽이구;한재호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.118-122
    • /
    • 2000
  • Recently, High accuracy and precision are required in various industrial field especially, semiconductor manufacturing apparatus, Ultra precision positioning apparatus, Information field and so on. Positioning technology is a very important one among them. For composition of this technology, the development of system with high speed and high resolution is needed. At start point and end position vibration must be repressed on this system for composition of position control. This vibration is arisen nose, is increased setting time, is reduced accuracy. Especially, repressed for the lead with high speed. The small actuator with high speed and high resolution is need to repression against this residual vibration. This actuator is, for example, piezo actuator, piezoelectric material that converting from electronic signal to mechanical force is adequate material, beacause of control of control to position and force. In this study, piezo electric material is used to actuator, ultra precision positioning apparatus with stage of hinge structure is designed, simulation is performed, control performance is tested by producing apparatus. For easy usage and stability in industrial field, we perform to simulation and to position control test by digital PID controller.

  • PDF

A Piezoelectric Lens Actuator for Mobile Information Devices (모바일 기기용 렌즈 구동 압전형 액츄에이터 개발)

  • Lee, Hun-Tae;Lee, Seung-Yop;Park, Young-Phil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.744-749
    • /
    • 2005
  • In this paper, a lens actuator for mobile devices is proposed using stack type piezoelectric materials. In general, the deformation of PZT actuators is not enough for lens motion when the allowed voltage is applied. The small stroke problem can be solved by accumulating a lot of small displacements in high frequency. In this paper, a new inch-worm type model for focusing actuator is suggested based on the interaction of inertial and frictional forces. Theoretical analysis and simulation using ANSYS are performed to verify the feasibility of the inch-worm PZT actuator model. Various types of clamps are considered to determine the effect of frictional force on the motion, and appropriate clamp-actuator models are proposed. The proposed models are experimentally verified and the experimental results show high correspondence with theoretical and simulated values. The inch-worm type focusing actuator enable a large stroke with 7.79 mm/sec with 10kHz and 10V.

  • PDF

Magnetic Actuator for a Capsule Endoscope Navigation System

  • Chiba, Atsushi;Sendoh, Masahiko;Ishiyama, Kazushi;Arai, Ken Ichi;Kawano, Hironao;Uchiyama, Akio;Takizawa, Hironobu
    • Journal of Magnetics
    • /
    • v.12 no.2
    • /
    • pp.89-92
    • /
    • 2007
  • The authors propose a magnetic actuator for use as a navigation system for capsule endoscopes. The actuator is composed of a capsule dummy, a permanent magnet inside the capsule, and an external spiral structure. The device rotates and propels wirelessly when exposed to an external rotational magnetic field. In this study we measured the effect of the spiral shape on the velocity and thrust force properties. According to our experimental results, the actuator obtained a maximum velocity and thrust force when the spiral angle was set at 45 degrees, the number of spirals was set at 4, and the spiral-height was set at 1-mmf. We also conducted a motion test in the large intestine of a pig placed on a 30 degrees slope. The actuator passed through a 700 mm length of the intestine in about 300 s. The device also managed to travel up and down the 30 degrees slope with no difficulty whatsoever. Our results demonstrate the great potential of this actuator for use as a navigation system for capsule endoscopes.

Robust Internal-loop Compensation of Pump Velocity Controller for Precise Force Control of an Electro-hydrostatic Actuator (EHA의 정밀 힘제어를 위한 펌프 속도 제어기의 강인 내부루프 보상)

  • Kim, Jong-Hyeok;Hong, Yeh-Sun
    • Journal of Drive and Control
    • /
    • v.15 no.4
    • /
    • pp.55-60
    • /
    • 2018
  • Force-controlled electro-hydrostatic actuators have to exhibit high backdrivability, to quickly compensate for force control errors caused by externally disturbed rod movement. To obtain high backdrivability, the servomotor for driving the hydraulic pump, should rotate exactly to such a revolution to compensate for force control errors, compressing or decompressing cylinder chambers. In this study, we proposed a modified velocity control structure, including a robust internal-loop compensator (RIC)-based velocity controller, for the servomotor to improve backdrivability of a force-controlled EHA. Performance improvement was confirmed experimentally, wherein sinusoidal velocity disturbance was applied to the force-controlled EHA, with constant reference input. Its dynamic force control errors reduced effectively, with the proposed control scheme, compared to test results with a conventional motordriver, for motor velocity control.