• Title/Summary/Keyword: Foot type

Search Result 541, Processing Time 0.035 seconds

The Damage Behavior of Glass/Epoxy and Aramid/Epoxy in Leaf Spring of Ankle Foot Orthosis (A.F.O) due to the Various Impact Velocities (족부보장구(A.F.O.) 판스프링용 Glass/Epoxy와 Aramid/Epoxy의 충격속도 변화에 따른 손상 거동)

  • Song Sam-Hong;Oh Dong-Joon;Jung Hoon-Hee;Kim Cheol-Woong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.10
    • /
    • pp.1526-1533
    • /
    • 2004
  • The needs of walking assistant device such as the Ankle Foot Orthosis (A.F.O) are getting greater than before. However, most of the A.F.O are generally imported rather than domestic manufacturing. The major reason of high import reliability is the rack of impact properties of domestic commercial products. Therefore, this research is going to focus on the evaluation of impact properties of the A.F.O which has the high import reliability. Unfortunately, these kinds of researches are not performed sufficiently. This research is going to evaluate impact energy behavior in composite materials such as the glass/epoxy (S-glass, [0/90]sub 2S/) and the aramid/epoxy (Kevlar-29, woven type, 8 ply) of ankle foot orthosis. The approach methods were as follows. 1) The history of impact load and impact energy due to the various velocities. 2) Relationship between the deflection and damage shape according to the impact velocities. 3) The behavior of absorbed energy and residual strength rate due to the various impact velocities.

Functional Evaluation of Tennis Shoes Using Foot-Pressure Distribution (족저압력분석을 활용한 테니스화 기능성평가)

  • Park, Seung-Bum;Lee, Joong-Sook
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.4
    • /
    • pp.89-97
    • /
    • 2008
  • The purpose of this study was to analyze the foot-pressure distribution of Tennis Shoes for assessing their functionality. 10 university male students (shoe size: 265mm) who had no history of injury in the lower extremity and a normal gait pattern participated in this study. Four types of tennis shoes, most popular in Korea (A, B, C & D company), were selected and tested. Using the PEDAR-X system and PEDAR-X insoles, 4 different motion stages were analyzed for the foot-pressure distribution: (a) straight running; (b) c-cut($45^{\circ}$ left turn running; (c) forehand stroke; and (d) backhand stroke. Results revealed that in all stages, there were no statistically significant differences among the types of shoes; however, descriptive statistics indicated that functionality of shoe types was somewhat different depending on the type of stages. The order in functionality found was C>A>B>D.

An Analysis of X-Factor, Triple X-Factor, and the Center of Pressure (COP) according to the Feel of the Golf Driver Swing

  • Kim, Yong-Seok;So, Jae-Moo
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.3
    • /
    • pp.265-272
    • /
    • 2016
  • Objective: The aim of this study was to analyze X-factor, triple X-factor, and the center of pressure (COP) according to the feel of golf driver swing. Method: For this research, 9 golfers from the Korea Professional Golfers' Association (age: $30.11{\pm}2.98yrs$, height: $178.00{\pm}8.42cm$, weight: $76.22{\pm}8.42kg$, experience: $10.06{\pm}3.11yrs$) were recruited to participate in the experiment. Twelve Motion Analysis Eagle-4 cameras were installed and an image analysis was conducted by using the NLT (non-linear transformation) method, and 2 units of Kistler type 5233A dynamometer were used to measure ground reaction force. The sampling ratio was set at 1000 Hz. The golfers each took 10 swings by using their own driver, and chose the best and worse feel from among 10 shots. A paired-sample t-test was used to analyze the results. Results: In regard to feel, no change in head speed, X-factor, and the triple X-factor's X-factor stretch, hip rise, and head swivel, was observed (p>.05). Regarding ground reaction force, a difference was observed between the top of the backswing (p<.05) and impact (p<.05) in the vertical force of the left foot. For COP, a difference was also observed between the mid backswing (p<.001), late backswing (p<.001), and top of the backswing (p<.05) for the right foot X-axis and Y-axis mid follow through (p<.01). Conclusion: It can be reasoned that, irrespective of feel, the head speed, X-factor and triple X-factor's X-factor stretch, hip rise and head swivel did not have an effect on drive distance for domestic golfers, and the vertical reaction force of the left foot and left-right movement span's pressure dispersal of the right foot had an increasing effect on drive distance.

Analysis of complete genome sequence of foot-and-mouth disease (FMD) Asia1 vaccine strain (구제역 Asia1 백신주의 전체 염기서열분석 및 특성)

  • Lee, Yeo-Joo;Chu, Jia-Qi;Lee, Seo-Yong;Kim, Su-Mi;Lee, Kwang-Nyeong;Ko, Young-Joon;Lee, Hyang-Sim;Cho, In-Soo;Nam, Seok-Hyun;Park, Jong-Hyeon
    • Korean Journal of Veterinary Service
    • /
    • v.34 no.2
    • /
    • pp.95-102
    • /
    • 2011
  • Foot-and-mouth disease (FMD) is one of the most infectious diseases affecting cloven-hoofed animals including cattle, sheep, goats, and pigs. Seven serotypes of foot-and-mouth disease virus with multiple subtypes within each serotype have been identified until now. In particular, it has been demonstrated that the outbreak of the serotype Asia1 reported from China, Mongolia and North Korea since 2005 is mostly classified into genetic group V. Though it has been recommended that Asia1 Shamir strain can be used as a high priority vaccine by World References Laboratory for FMD, the complete nucleotide sequences of the strain has not yet been determined. In this study, to be prepared for Asia1 type viruses that may be brought into Korea, the complete genome sequence of this vaccine strain Asia1 Shamir including its 5' and 3' non-coding region was identified.

Development of Gait Monitoring System Based on 3-axis Accelerometer and Foot Pressure Sensors (3축 가속도 센서와 족압 감지 시스템을 활용한 보행 모니터링 시스템 개발)

  • Ryu, In-Hwan;Lee, Sunwoo;Jeong, Hyungi;Byun, Kihoon;Kwon, Jang-Woo
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.3
    • /
    • pp.199-206
    • /
    • 2016
  • Most Koreans walk having their toes in or out, because of their sedentary lifestyles. In addition, using smartphone while walking makes having a desirable walking posture even more difficult. The goal of this study is to make a simple system which easily analyze and inform any person his or her personal walking habit. To discriminate gait patterns, we developed a gait monitoring system using a 3-axis accelerometer and a foot pressure monitoring system. The developed system, with an accelerometer and a few pressure sensors, can acquire subject's foot pressure and how tilted his or her torso is. We analyzed the relationship between type of gate and sensor data using this information. As the result of analysis, we could find out that statistical parameters like standard deviation and root mean square are good for discriminating among torso postures, and k-nearest neighbor algorithm is good at clustering gait patterns. The developed system is expected to be applicable to medical or athletic fields at a low price.

Combined Percutaneous and Minimal on Internal Fixation of Calcaneal Fractures Using Extensile Lateral Approach (광범위 외측 도달법을 이용한 종골 골절의 경피적 및 최소 내고정술)

  • Yu, Sun-O;Kim, Joo-Sung;Kim, Jong-Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.6 no.2
    • /
    • pp.201-207
    • /
    • 2002
  • Purpose: To present the clinical analysis of the results obtained in 38 cases of displaced intraarticular calcaneal fractures undergone combined percutaneous axial pin fixation of calcaneal body and minimal internal fixation using extensile lateral approach. Materials and Methods: From March 2000 to February 2002, thirty-eight displaced intraarticular fractures of the calcaneus in 35 patients were fixed with 3.5mm cannulated screws and percutaneous 2.5mm K-wires. The extensile lateral approach was used in all cases. The average follow-up period was 16 months. Clinical evaluation was assessed according to the Ankle-Hind Foot Scale of American Orthopedic Foot and Ankle Society. Results: The clinical results were graded as excellent in 8 cases(21%), good in 22 cases(58%), fair in 6 cases(16%), and poor in 2 cases(5%). Two cases of poor result were type IV of Sanders classification. The postoperative reduction status of the articular surface was analyzed by computed tomography in all cases and was found to be less 2mm of step off in 30 cases and between 2 and 4mm in 8 cases. Unsatisfactory results were correlated with severity of articular comminution and failure to obtain accurate reduction of the articular surface. Using early functional postoperative care, all fractures healed without secondary displacement except 1 case on an average of ten weeks. Two cases had superficial necrosis of the wound margins, however, secondary wound healing was uneventful and skin grafting was not needed. Conclusion: Combined minimal internal fixation and percutaneous pin fixation using extensile lateral approach is useful operative method of intraarticular calcaneal fractures because providing enough stability to permit functional aftercare and allowing excellent anatomical reduction. In addition, this method diminishes the risk of lateral soft tissue problems.

  • PDF

Fragmented Split-Thickness Skin Graft Using a Razor Blade in Burn Induced Diabetic Foot (화상을 동반한 당뇨발 환자에게 Razor Blade를 이용한 부분층피부조각 이식술의 효용성)

  • Park, Cheol-Heum;Choi, Manki;Kang, Chan-Su;Kim, Tae-Gon
    • Journal of the Korean Burn Society
    • /
    • v.23 no.1
    • /
    • pp.20-24
    • /
    • 2020
  • Diabetic patients have an increased risk of burn injuries on foot. Because of their diabetic neuropathy, they could contact with hot water or warming device without being aware of it. Split-thickness skin graft (STSG) is successful in treatment of various wound types; however, donor site wounds are sometimes problematic, and complications such as pain and impaired healing often occur. Although, donor site wounds in healthy young individuals can rapidly heal without complications, the wound-healing capacity of elderly patients or those with a comorbidity has been reported to be low. The dermatome is the most commonly used tool because it can harvest a large skin graft in one attempt. However, it is difficult to harvest tissues if the area is not flat. Furthermore, because the harvested skin is usually rectangular, additional skin usually remains after skin grafting. Therefore, use of razor blade and fragmented STSG on a large defect area is advantageous for harvesting a graft with a desired size, shape, and thickness. From January 2018 to July 2018, fragmented STSG was used in 9 patients who suffered from burn induced open wound on foot with diabetic neuropathy. With this approach, healing process was relatively rapid. The mean age of patients was 70 (57~86 years) and all of 9 patients had diabetes mellitus type 2. In all patients, the skin graft on the defect site healed well and did not result in complications such as hematoma or seroma.

A Study on the Recruitment Pattern and Changes of the Role Assigned to Lower Extremity Muscles by EMG Analysis (근전도를 이용한 하지근육의 동원형태 및 역할분담 분석에 관한 연구)

  • 황규성;정의승;이동춘
    • Proceedings of the ESK Conference
    • /
    • 1995.04a
    • /
    • pp.72-83
    • /
    • 1995
  • This study are to investigate the variations of the recruitment patterns of the nine lower extremity muscles, and to analyze the changes of the role assigned to each muscle during the seated posture. For exertion levels, the transition point of type F more unit of each muscle is inferred by analyzing the electromyogram at the seated postures. Also, for predetermined seated foot operations exertion levels, the recruitment pattern and the changes of the role assigned are identified in the continuous exertion, by analyzing the electromyogram change sdue to the accumulated muscle fatigue. The developed model can be used to design and to assess the pedals and foot-related equipments design.

  • PDF

The Study of Core Muscle as Meridian Tendino-usculature ('코어(core)'근육에 대한 한의학적 소고(小考))

  • Song, Yun-Kyung;Lim, Hyung-Ho
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.7 no.2
    • /
    • pp.77-84
    • /
    • 2007
  • Obejectives : Slow-motion strengthening trainings build up muscles better than any other type of training, these exercises focus on balancing and strengthening the muscles in the anatomical center of the body - the core - which includes the back, hip and abdominal muscles. Methods : We had a concept of 'core', and compared core muscles with 12 meridian tendino-musculature based on Thomas Myers' myofascial meridian. Results : It has been suggested that the core muscles correspond to meridians of foot- three Yin and foot- three Yang. The study of core muscles strengthening exercise and movement therapy is requred.

  • PDF

Design of 4 joints 3 Link Biped Robot and Its Gaits (4관절 3링크 2족 로봇과 걸음새에 관한 연구)

  • Kim, Sung-Hoon;Oh, Jun-Ho;Lee, Ki-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.523-528
    • /
    • 2000
  • In this paper, the new type biped walking robot which is composed of the minimum number or links just for walking and its appropriate gaits are proposed. The proposed new gaits for this robot are four-crossing, crawling, standing and turning gait. In designing the biped robot we propose the Performance Index which means the needed torque per a moving distance and generate foot trajectories by $3^{rd}$ order spline Interpolation. Among those, numerically we find the optimal conditions which minimize the Performance Index. Dynamically stable walking of the biped robot is realized by satisfying the stability condition of ZMP(zero moment point), which is related to maintaining the ZMP within the region of the supporting foot during the s1n91e leg support phase. We determine the region of mass center from the stability condition of ZMP and plan references which track the mass conte. trajectory of constant velocity. Finally we implement the gaits statically tracking the planned trajectories using PD control method.

  • PDF