• Title/Summary/Keyword: Foot measure

Search Result 239, Processing Time 0.027 seconds

The Effects of the Bojungikgi-tang added Magnoliae Flos on the Pulmonary Thromboembolism and Delayed Allergy Response (보중익기탕(補中益氣湯) 가(加) 신이(辛夷)가 폐혈전색전(肺血栓寒栓) 및 지연형(遲延型) allergy반응(反應)에 미치는 영향(影響))

  • Kang, Yoon-Kyung;Park, Dong-Il;Kang, Pil-Koo
    • The Journal of Internal Korean Medicine
    • /
    • v.21 no.3
    • /
    • pp.487-493
    • /
    • 2000
  • Objective : This experimental studies were done to research the effects of Bojungikgi-tang added Magnoliae Flos on the pulmonary thromboembolism and delayed allergy response. Methods : Healthy rats were devided into each group. This test is to inject sodium arachidonic acid to one group, and ADP(adenocine diphophate) to the other one afterward to compare the survival rate between each other. Delayed allergy response test is to inject PC(picryl chloride) to one group and measure the thickness of their ears, to inject SRBC(sheep red blood cell) allergen to the other, and measure their foot edema, and compare the each other rates Results : The extract of the Bojungikgi-tang added Magnoliae Flos revealed significant effect on the pulmonary thromboembolism induced by sodium arachidonate, or adenocine diphophate(ADP). And the extract of the Bojungikgi-tang added Magnoliae Flos revealed significant effect on delayed type hypersensitivity induced by picryl chloride(PC), or sheep red blood cell(SRBC). Conclusions : According to the above findings it is suggested that the extract of the Bojungikgi-tang added Magnoliae Flos revealed significant effect on the delayed type hypersensitivity and effect on the pulmonary thromboembolism.

  • PDF

Design of Calf Link Force Sensor of Walking Assist Robot of Leg Patients (편마비 다리환자를 위한 보행보조로봇의 발목 2축 힘센서 설계)

  • Choi, Chi-Hun;Kim, Gab-Soon
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.353-359
    • /
    • 2017
  • This paper describes the design and manufacture of a ankle two-axis force sensor of a walking assist robot for hemiplegic leg patient. The walking assist robot for the hemiplegic leg patient can safely control the robot by detecting whether the foot wearing the walking assist robot is in contact with the obstacle or not. To do so, a two-axis force sensor should be attached to the robot's ankle. The sensor is used to measure the force of a patient's ankle lower part. The two-axis force sensor is composed of a Fx force sensor, a Fy force sensor and a pulley, and they detect the x and y direction forces, respectively. The two-axis force sensor was designed using by FEM(Finite Element Method), and manufactured using by strain-gages. The characteristics experiment of the two-axis force sensor was carried out respectively. The test results indicated that the interference error of the two-axis force sensor was less than 1.2%, the repeatability error and the non-linearity of the two-axis force sensor was less than 0.04% respectively. Therefore, the fabricated two-axis force sensor can be used to measure the force of ankle lower part in the walking assist robot.

Development of lntelligent Shoe System to Measure Applied Force/Moment on the Sole of a Foot during Human Walking (사람 보행시 발바닥의 힘정보를 측정하기 위한 지능형 신발시스템 개발)

  • Kim, Gab-Soon;Kim, Hyeon-Min;Hu, Duck-Chan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.7
    • /
    • pp.79-86
    • /
    • 2008
  • This paper describes the development of wearing intelligent shoe system to measure applied forces and moments (ground reaction forces and moments) on the soles of feet during human walking. In order to walk safely, robot must get the intelligent feet with 6-axis force/moment sensors (Fx sensor (x-direction force sensor), Fy sensor, Fz sensor, Mx sensor (Mx : x-direction moment sensor), My sensor, and Mz sensor) and detect the forces and moments data from the sensors. And the feet must be controlled with the data and controllers. While a human is walking, the forces and moments should be measured and analyzed for robot's intelligent feet. Therefore, the wearing intelligent shoe system should be developed. In this paper, four 6-axis farce/moment sensors and two high speed measuring devices were designed and fabricated, and the wearing intelligent shoe system was made using these. The characteristic tests of the wearing intelligent shoe system were performed, and the forces and moments were detected using it.

A Study on the Estimation of Smartphone Movement Distance using Optical Flow Technology on a Limited Screen (제한된 화면에 광류 기술을 적용한 스마트폰 이동 거리 추정에 관한 연구)

  • Jung, Keunyoung;Oh, Jongtaek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.4
    • /
    • pp.71-76
    • /
    • 2019
  • Research on indoor location tracking technology using smartphone is actively being carried out. Especially, the movement distance of the smartphone should be accurately measured and the movement route of the user should be displayed on the map. Location tracking technology using sensors mounted on smart phones has been used for a long time, but accuracy is not good enough to measure the moving distance of the user using only the sensor. Therefore, when the user moves the smartphone in a certain posture, it must research and develop an appropriate algorithm to measure the distance accurately. In this paper, we propose a method to reduce moving distance estimation error by removing user 's foot shape by limiting the screen of smartphone in pyramid - based optical flow estimation method.

The Effect of Differential Medial and Lateral Midsole Hardness on Rearfoot Movement (운동화 후족의 내외측 경도차에 따른 후족 제어의 효과)

  • Bu, Jin-Hu;Lee, Dong-Chun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.63-72
    • /
    • 2001
  • Rearfoot control can be defined as the relative ability of a shoe to limit the amount of subtalar joint pronation immediately following footstrike. A normal amount of pronation provides a means of decreasing peak forces experienced by the leg, but excessive pronation of the foot can be arised its injures. The purpose of this study is to compare amount of pronation according to a difference between medial and later hardness of shoe midsole for better design of running shops. The experiment is examined for 7 running shoes. 8 males. to measure the Achilles tendon angle and rearfoot angle using high speed camera. The results is conducted that the changes of Achilles tendon angle significantly differ at each test shoe with increased running speed. And, a difference between medial and lateral hardness of midsole affects rearfoot motion of runner. The displacements of maximal Achilles tendon angle described a amount of pronation motion is decreased when medial hardness of midsole is large more than lateral.

  • PDF

A Study on the Rhythm of Korean EFL Learners' English Pronunciation (한국인 영어학습자의 영어리듬구현 연구)

  • Chung, Hyun-Song
    • Phonetics and Speech Sciences
    • /
    • v.1 no.2
    • /
    • pp.141-149
    • /
    • 2009
  • An emphasis on teaching suprasegmental features of English, specifically English rhythm, is essential in order to improve the 'intelligibility' of the pronunciation of Korean EFL learners among interlocutors who use English as a Lingua Franca(ELF). By redefining the ELF suggested by Jenkins (2000, 2002), this paper argues that Lingua Franca Core (LFC) must include suprasegmental features such as 'stress-based rhythm' and word stress. However, because 'isochrony' is difficult to measure in a foot, the rhythm unit must be expanded to an intonational phrase which has prominence in it and the rhythm of the unit can be measured by calculating the duration of each segment in context The rhythmic pattern of Korean learners of English and that of native speakers or other non-native English speakers can then be calculated and compared by using correlation coefficients of the segmental duration. In terms of sociolinguistic factors, improving the 'comprehensibility' and 'accentedness' of Korean EFL learners' pronunciation is also important in international communication, which calls for more emphasis on suprasegmental features.

  • PDF

The effects of high hell on back muscle fatigue (High Heel이 허리 근육 피로에 미치는 영향에 관한 연구)

  • 현수돈;김정룡
    • Journal of the Ergonomics Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.37-48
    • /
    • 1997
  • It is very common for women wear shoes with a high heel. It has been known that the high heel could disfigure the foot shape and cause various joint problems including back pain. However, few quantitative studies have been conducted. Therefore, in this study, the low back muscle has been investigated in order to find fatifue effect due to different heights of the heel. In particular, 0, 4, 6 and 8cm heel and two different shapes of heel have been used for an experiment. Ten healthy female subjects volunteered for the study. Isometric Trunk Exertion Frame(ITEF) and Electromyography were used to measure tha Median Frequency via Spectral analysis. The results indicated that the heel height significantly affected the local muscle fatigue of the back. After post hoc analysis, it was found that a proper heel height ougth to be lower than 5cm not to have severely fatigued back muscle after a casual walk for an hour. Such results could be applies to female industrial workers in order to prevent a cumulative trauma disorder of the back, and also to design a female dress shoes minimizing low back fatigue.

  • PDF

Estimation of grain size data from the hydraulic conductivity (투수계수로부터 입도분포 자료의 추정)

  • Nkomozepi, Temba;Chung, Sang-Ok
    • Current Research on Agriculture and Life Sciences
    • /
    • v.29
    • /
    • pp.29-35
    • /
    • 2011
  • The relationship between hydrologic processes and scale is one of the more complex issues in surface water hydrology. Disturbances that change vegetation and/or soil properties have been known to subsequently alter the landscape. The primary objective of this study was to estimate the grain size of soils with different properties from the hydraulic conductivity using pedotransfer functions. The double ring infiltrometer method was used to measure the vertical hydraulic conductivity of three soils under different soil planar surface treatments. Seven selected pedotransfer functions were used to estimate percentile diameters and the reduction in infiltration caused by compaction was misconstrued as caused by changes in percentile diameter. Results showed that compaction on the sandy loamy foot paths reduced the hydraulic conductivity by about 50%. The study showed that perceptual models of infiltration processes and appreciation of scale problems in modeling are far more sophisticated than normally presented in texts. Hydraulic measurement methods are still relevant and will provide significant information of grain size of the soils.

  • PDF

A Study on the Lymphangiography Used Hrdro-Static Pressure (Lead Container를 이용(利用)한 임파조영술(淋巴造影術)에 대(對)한 고찰(考察))

  • Park, Jun-Chul;Lim, Han-Young;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.2 no.1
    • /
    • pp.100-100
    • /
    • 1979
  • For eighteen months from May, 1977, to November, 1978, I found out the following conclusion with the references when the author had the test of Lymphangiography for malignant lymphoma and cervix cancer of uterus who had the suspicion of nodal metastasis who amounted 56 patients. 1. According to the test 40 patients among 56 were succesful, almost 71% of t-them, injecting needles at both pedis, and it showed some technical difficulties in Lymphangioraphy comparing with other diagnostic measure. 2. As the result of Lymphangiography of 56 patients, they complained pains, edema of foot. In the course of finding out lymphatic vessel there was exudation due to high pressure at the insected part. At the process and at that test there have been frequent complains by the patients about some sort of pains and some times severe pains.

  • PDF

A Design of Digital Inclinometer for Measuring Postural Balance (Preliminary Study) (자세 균형 측정을 위한 디지털 경사계 설계)

  • Myoung, Hyoun-Seok;Lee, Hyo-Ki;Lee, Kyoung-Joung;Kwon, Oh-Yun
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.238-240
    • /
    • 2006
  • In this study, we designed a digital inclinometer to measure the angle and acceleration signals. Digital inclinometer consists of a tilt sensor, accelerometer, one-chip micro controller and BlueTooth module. Using the developed system, we made an experiment with Roll. The subject is laid on the Roll and rises each foot $90^{\circ}$ and $45^{\circ}$ up, and measures angle and acceleration signals with 100Hz sampling frequency. Through several tests, we could find the possibilities and usefulness which can evaluate normality / abnormality of body posture objectively.

  • PDF