• Title/Summary/Keyword: Food waste water

Search Result 315, Processing Time 0.022 seconds

Distribution of Marine Bacteria and Coliform Groups in Puksin Bay, Korea (북신만의 대장균군 및 해양세균의 분포)

  • CHOI Jong-Duck
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.2
    • /
    • pp.202-208
    • /
    • 1995
  • Puksin Bay located in the northwestern pan of Tongyeong, Korea has been contaminated by municipal wastewaters. In Puksin Bay, red tides have occured almost every year since the early 1980's. This experiment was carried out two times in a month in the winter in 1990, the summer' 1991, and the winter in 1994 so as to clarify the distribution marine bacteria and coliform groups in Puksin Bay. The water quality of Puksin Bay was not only move polluted than that of any other costal area around Tongyeong, but also its water quality was investigated to keep going bad. Viable cell counts in Puksin Bay were $4.9\times10^3/ml$ in 1990's winter, $3.6\times10^6/ml$ in 1991's summer, and $2.1\times10^4/ml$ in 1994's winter. The variation of seasonal total and fecal coliform MPN/100ml in Puksin Bay were $6.7\times10^2\;and\;2.6\times10^2$ in 1990's winter, $1.5\times10^4$ and $5.4\times10^3$ in 1991's summer, and $1.5\times10^3$ and $5.6\times10^2$ in 1994's winter, respectively. The changes of stational total coliform MPN/100m1 from station 1 to station 8 in Puksin Bay were 95,000, 1600, 1,000, 182, 151, 94, 43 and 13 in winter, and 110,000, 29,000, 2,400, 4,100, 1,700, 1,700, 810 and 150 in 1991's summer, and 3,381, 1928, 1582, 256, 161, 59 and 23 in 1994's winter. During the study period, the number of viable cell was ranged from $10^4\;to\;10^7/ml$ and 307 bacteria strains were isolated from Puksin Bay. The dominant species were Acinetobacter spp. 86 $(28.3\%)$, Pseudomonas spp. 51 $(16.6\%)$, Flavobacterium spp. 41 $(13.4\%)$, Escherichia coli 36 $(11.7\%)$, and Vibrio spp. 27$(8.8\%)$. The results obtained in this study indicate that this bay is getting to contaminate far more with municipal wastewaters and cultivation of the shellfish and finfish in this bay is not proper. When municiple wastewaters keep flowing into this bay, any other coastal area around Tongyeong may be contaminated.

  • PDF

Nitrogen and Phosphorus Loss with Runoff and Leachate from Soils Applied with Different Agricultural By-product Composts (부산물 퇴비를 시용한 토양에서 표면유거와 용탈에 의한 질소와 인의 유실)

  • Park, Chol-Soo;Joo, Jin-Ho;Lee, Won-Jung;Yoo, Kyung-Yoal;Yang, Jae-E;Ok, Yong-Sik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.38 no.6
    • /
    • pp.307-312
    • /
    • 2005
  • Since alpine upland in Pyungchang-gun has been typically applied every two or three years with saprolite, agricultural by-products are inputted to raise soil properties. Therefore, the effect of saprolite application on water quality in runoff and leachate should be monitored. To investigate water quality in runoff and leachate with various treatments of agricultural by-product, lysimeter with dimension of $0.85m{\times}1.75m{\times}0.30m$ was installed in Kangwon National University. Control, mixed compost with cow, chicken and sawdust by-product (CCSC), chicken manure by-product compost (CC), food waste by-product compost (FWC), and beer sewage sludge by-product compost (BSSC) at the rate of $10Mg\;ha^{-1}$ were mixed with soil in 25 cm depth, and water qualities in runoff and leachate were monitored from Jun. 4, 2004 to Oct. 18, 2004. EC ($0.8-2.2dS\;m^{-1}$) and concentrations of total N ($25-75mg\;L^{-1}$) and total P ($0.12-0.43mg\;L^{-1}$) were highest in both runoff and leachate of CC treatment. EC values in CC and FWC treatments continuously increased during lysimeter experiment, while total N and total P concentrations continuously decreased. Average total N concentrations in runoff taken from CCSC, FWC and BSSC treatments were 41, 34 and $37mg\;L^{-1}$, and in leachate were 35, 28 and $34mg\;L^{-1}$, respectively. Average total P concentrations were not different with different treatments. EC values in leachate were higher than those in runoff, and total N concentrations in runoff were higher than those in leachate.

Bacteriocidal Effects of Ultraviolet Irradiation for Reducing Bovine Mastitis Derived from Environmental Contamination (우분뇨 유래 젖소 유방염 저감을 위한 자외선 조사 살균의 효과 규명)

  • Kim, Dong-Hyeok;Lim, Jung-Ju;Lee, Jin-Ju;Jang, Hong-Hee;Jang, Dong-Il;Lee, Seung-Joo;Lee, Hu-Jang;Min, Won-Gi;Kwon, Sun-Hong;Kim, Sang-Hun;Oh, Kwon-Young;Kim, Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.4
    • /
    • pp.435-440
    • /
    • 2008
  • Bovine mastitis is an important disease causing serious economic loss in dairy production and food poison in public health. The major causative agents of bovine mastitis include Escherichia coli (E. coli), Streptococcus agalactiae (S. agalactiae), Staphylococcus aureus (S. aureus). These bacteria were found in milk and environmental condition such as feces, water, soil and so on. Recently, many cases of mastitis are derived from environmental contamination of micro-organisms, which important factors for the spread of this disease in farm. Ultraviolet irradiation (UV) has been used as disinfection for waste and water in clinical and industrial facilities. Moreover the UV irradiation has been used as useful bactericidal agents to remove bacterial biofilms in environmental condition. In this study, we determined the bacterial replication in different percentage of water content (PWC) in sterilized saw dust and feces complexes from farm, and results showed that slightly decreased growth pattern of E. coli and S. agalactiae but increased growth pattern of S. aureus in various PWC (200, 400 and 600%) until 144 h incubation. In the bacteriocidal effect of UV irradiation to bacteria in saw dust and feces complex, the results showed that bacteriocidal effect was depended on the UV irradiation time, irradiation distance and PWC. Especially the antibacterial activity of UV irratiation is stronger in low PWC (50%), long time irradiation (50 sec), and short distance (5 cm) than other condition of this study. Furthermore UV irradiation with stirring showed increased the bactericidal effect compared without stirring. These results suggested that bovine mastitis causing agents may survive long time in environmental condition especially saw dust and feces complexes in farm and can cause a various disease including mastitis. Moreover, these data can be used as basis for application and development of UV disinfection to control of bovine mastitis from environmental contaminated bacteria in dairy farm.

Optimization of Separation Process of Bioflavonoids and Dietary Fibers from Tangerine Peels using Hollow Fiber Membrane (중공사 막을 이용한 감귤 과피 bioflavonoids 분리 및 식이 섬유 회수 공정 최적화)

  • Lee, Eun-Young;Woo, Gun-Jo
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.151-160
    • /
    • 1998
  • Tangerine peel is mostly discarded as waste in citrus processing. However, tangerine peel contains besides dietary fibers bioflavonoids such as naringin and hesperidin which act as antimicrobials and blood pressure depressants, respectively. A continuous membrane separation process was optimized for the production of bioflavonoids relative to feed flow rate, transmembrane pressure, temperature, and pH. The tangerine peel was blended with 7.5 times water volume and the extract was prefiltered through a prefiltration system. The prefiltered extract was ultrafiltered in a hollow fiber membrane system. The flux and feed flow rate didn't show any apparent correlation, but we could observe a mass-transfer controlled region of over 8 psi. When temperature increased from $9^{\circ}C\;to\;25^{\circ}C$, the flux increased about $10\;liters/m^2/min\;(LMH)$ but between $25^{\circ}C\;and\;33^{\circ}C$, the flux increased only 2 LMH. At every transmembrane pressure, the flux of pH 4.8 was the most highest and the flux at pH 3.0 was lower than that of pH 6.0, 7.0, or 9.0. Therefore, the optimum operating conditions were 49.3 L/hr. 10 psi, $25^{\circ}C$, and pH 4.8. Under the optimum conditions, the flux gradually decreased and finally reached a steady-state after 1 hr 50 min. The amount of dietary fibers in 1.0 g retentate in each separation step was analyzed and bioflavonoids concentration in each permeate was measured. The contents of total dietary fiber in the 170 mesh retentate and soluble dietary fiber in the prefiltered retentate were the highest. Naringin and hesperidin concentration in the permeate were $0.45{\sim}0.65\;mg/g\;and\;5.15{\sim}6.86\;mg/g$ respectively, being $15{\sim}22$ times and $79{\sim}93$ times higher than those in the tangerine peel. Therefore, it can be said that PM 10 hollow fiber membrane separation system may be a very effective method for the recovery of bioflavonoids from tangerine peel.

  • PDF

Evaluating the Removal Efficiency of Organic Compounds and Nitrogen Depending on Loading Rate in Wastewater Treatment from Fisheries Processing Plant Using an Entrapped Mixed Microbial Cell Technique (미생물 강제포획기술을 이용한 수산물 가공공장 폐수처리에서 부하율에 따른 유기물 및 질소의 제거 효율성 평가)

  • Jeong Byung-Cheol;Chang Soo-Hyun;Jeong Byung-Gon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.1
    • /
    • pp.14-20
    • /
    • 2006
  • In this study, the feasibility of simultaneous removal of organic materials and nitrogen in the waste-water from fisheries processing plant was evaluated using entrapped mixed microbial cell technique(EMMC) process. The experiment was performed using activated sludge from municipal sewage treatment plant which was immobilized with gel matrix by cellulose triacetate. It was found that the stable operation at the treatment system which is composed of anoxic and oxic tank, was possible when the organic and nitrogen loading rates were increased stepwise. The organic and nitrogen loading rates were applied from 0.65 to $1.72kgCOD/m^3/d$ and from 0.119 to $0.317kgT-N/m^3$ with four steps, respectively. The maximum nitrogen loading rate which could satisfy the regulated effluent standard of nitrogen concentration, was $0.3kgT-N/m^3/d$. The removal efficiency of total nitrogen was decreased apparently as increasing nitrogen loading rates, whereas the removal efficiency of ammonium nitrogen was effective at the all tested nitrogen loading rates. Therefore, it was concluded that nitrification was efficient at the system. Nitrate removal efficiency ranged from 98.62% to 99.51%, whereas the nitrification efficiency at the oxic tank ranged 94.0% to 96.9% at the tested loading rates. The removal efficiencies of chemical oxygen demand(COD) and those of total nitrogen at the entire system ranged from 94.2% to 96.6% and 73.4% to 83.4%, respectively.

  • PDF