• 제목/요약/키워드: Foil arrangement

검색결과 4건 처리시간 0.021초

제트 노즐의 배치가 콴다 날개의 성능에 미치는 영향 (Influence of Jet Nozzle Arrangement on the Performance of a Coanda Foil)

  • 서대원;김종현;김효철;이승희
    • 대한조선학회논문집
    • /
    • 제45권6호
    • /
    • pp.569-578
    • /
    • 2008
  • The Coanda effects demonstrate that a jet stream applied tangential to a curved surface can generate lift force by increasing the circulation. Many experimental and numerical studies have been performed on the Coanda effect and it is found to be useful in various fields of aerodynamics. The Coanda effect may have practical application to marine hydrodynamics since various control surfaces are being used to control behaviors of ships and offshore structures. In the present study, numerical computations are performed to find the applicability of the Coanda effect to the marine control surfaces. For the purpose, changes in flow characteristics around a flapped foil due to the Coanda effect have been simulated by RANS equations discretized with a cell-centered finite volume method (FVM). In the process, special attention has been given to the influence of jet nozzle arrangement on the lift characteristics of the Coanda foil. It is found that the shape as well as the location of the jet intake and jet exit affects the lift performance of the foil significantly.

고속선 운항 안정성을 위한 수중익 배치 및 종모멘트 특성에 관한 실험적 연구 (Experimental Study on Hydrofoil Arrangement and Longitudinal Moment Characteristics for Navigation Safety of High Speed Craft)

  • 박화평;김상현;임근남
    • 해양환경안전학회지
    • /
    • 제20권4호
    • /
    • pp.443-450
    • /
    • 2014
  • 본 연구에서는 수중익 배치와 종모멘트 특성이 전몰형 수중익선의 종방향 운동 안정성에 미치는 영향에 대하여 Tandem 수중익 모형의 시험을 통하여 고찰한다. 먼저, Canard 날개배치를 가지는 Tandem 수중익 모형을 제작하고 수중익의 양력 및 항력 계측 실험을 수행하여 양력 및 항력 특성을 평가하였다. 또한 종방향 운동의 초기 안정성과 자기 안정성을 가지는 Tandem 수중익 모형의 날개 배치를 결정하였다. Tandem 수중익 모형의 종안정성 시험에서는 선수 및 선미 수중익의 종방향 간격 변화와 종모멘트의 자기안정성 변화에 따른 Pitch 및 Heave 운동 특성, 익주 상태의 종안정성을 평가하였다. 먼저, Canard 날개배치를 가지는 Tandem 수중익 모형을 제작하고 수중익의 양력 및 항력 계측 실험을 수행하여 양력 및 항력 특성을 평가하였다. 또한 종방향 운동의 초기 안정성과 자기 안정성을 가지는 Tandem 수중익 모형의 날개 배치를 결정하였다. Tandem 수중익 모형의 종안정성 시험에서는 선수 및 선미 수중익의 종방향 간격 변화와 종모멘트의 자기안정성 변화에 따른 Pitch 및 Heave 운동 특성, 익주 상태의 종안정성을 평가하였다. 실험 수행 결과 본 연구의 주요 결론의 다음과 같다. 종 모멘트 자기 안정성이 클수록 주어진 고정 pitch 각에서 pitch운동에 대한 자기안정성이 높다. 다음 종모멘트 자기 안정성이 클수록, pitch각도 변화에 따른 pitch운동 및 heave운동의 변동 폭이 상대적으로 작으며 종방향 안정성이 우수하다. 마지막으로 종모멘트 자기안정성이 클수록, 수중익 양력이 동일한 경우, Tandem 수중익의 안정적인 익주를 위해서는 충분한 종모멘트의 자기안정성을 확보하는 것이 필수적인 것을 시험을 통하여 확인하였다.

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • 한국결정학회:학술대회논문집
    • /
    • 한국결정학회 2002년도 정기총회 및 추계학술연구발표회
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

백서의 실험적 치아이동시 osteonectin 및 osteocalcin의 발현 (THE EXPRESSION OF OSTEONECTIN AND OSTEOCALCIN IN THE EXPERIMENTAL TOOTH MOVEMENT IN RAT)

  • 배성렬;김상철
    • 대한치과교정학회지
    • /
    • 제28권5호
    • /
    • pp.699-716
    • /
    • 1998
  • 본 연구는 열을 이용한 금속 브라켓의 재생 처리시, 기저부 형태와 브라켓 재생 방법에 따른 전단접착강도 및 브라켓 탈락 양상을 비교하고자 시행되었다. 교정 치료를 위해 발거된 건전한 소구치 252개를 수집하고, Type I, Type II, Type III 스탠다드 브라켓을 각각 재생 방법에 따라 네 군으로 나누어 준비된 소구치에 접착하고, Instron Universal Testing Machine(Model 4466)으로 전단접착강도를 측정하였으며, 브라켓의 탈락 양상을 관찰하고 브라켓 기저부의 주사전자현미경 소견을 관찰하였다. SPSS 통계처 리 프로그램을 이용하여 일원분산분석(oneway ANOVA), Scheffe's multiple range test를 실시하여 다음과 같은 결론을 얻었다. 1. 브라켓 기저부 형태에 따른 전단접착강도는 유의차가 있었으며(p<0.001), 그 크기는 Type III(round indentation, micro-etched base), Typ I(foil-mesh base), Type II(grooved integral base, micro-etched)의 순이었다. 2. 생 방법에 따른 전단접착강도는, Type I, Tpe II 브라켓에서는 Big Jane에 1분간 처리시 우수한 결과를 보였고 (p<0.05), Type III 브라켓에서는 각 군간 유의한 차이를 보이지 않았다(p>0.05). 3. Type I, Type II 브라켓은 기저부-레진 계면에서 가장 높은 빈도로 탈락하였고, Type III 브라켓에서는 레진의 절반 가량이 치면에 잔존하는 탈락 양상이 가장 많았다. 4. 탈락 양상에 따라 탈락시의 전단접착강도가 유의성 있는 차이를 보였는데(p<0.05),브라켓 탈락시 접착제의 절반 가량이 치면에 잔존하는 경우 전단접착강도가 가장 큰 것으로 나타났다. 5. 브라켓 재생 후 기저부에 남아 있는 접착제는 전단접착강도의 감소에 영향을 미치지 않았다.

  • PDF