• Title/Summary/Keyword: Focal Position

Search Result 142, Processing Time 0.028 seconds

PANORAMIC IMAGE OF MANDIBULAR CONDYLE ACCORDING TO HEAD POSITION (두부 위치에 따른 하악 과두의 파노라마상)

  • Kim Jeong Hwa;Choi Soon Chul
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.219-225
    • /
    • 1990
  • Panoramic radiography is convenient in clinic and visualizes those areas which other technique do not give. But the technique has limitation of image distortion which results from the relationship of the ramus to the focal trough and from the direction of the central ray. This study is, using 7 dry skulls, to determine the effect of rotation of patient's head on reducing those distortion and determine the magnification ratio of images of mandibular condyle in rotated patient head position. The obtained results were as follows: 1. Generally, in panoramic radiography the anterolateral portion of the mandibular condyle was best to be visualized. 2. There are no significant difference between the image readability of anteromedial portion and that of anterocentral portion of the mandibular condyle. 3. Anterolateral portion of the mandibular condyle was better visualized in rotated head position by 20 degree or horizontal condylar inclination than in conventional position or in rotated head position by 10 degree. 4. The magnification ratio of the anteroposterior diameter in the image of mandibular condyle was least in the rotated head position by horizontal inclination of the mandibular condyle and was largest by 20 degree.

  • PDF

Spatial Characterization of MAC, a High-Resolution Optical Earth Observation Camera for Small Satellites

  • Kim Eugene D.;Choi Young-Wan;Yang Ho-Soon;Ismail Mohd. Afiq bin
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.79-83
    • /
    • 2005
  • Spatial calibrations have been performed on the Medium-sized Aperture Camera (MAC) of the RazakSAT satellite. Topics discussed in this paper include the measurements of system modulation transfer function (MTF), relative pixel line-of-sight (LOS), and end-to-end imaging tests. The MTF measurements were made by capturing the scanned knife-edge image on a pixel, and an issue in the MTF calculation algorithm is discussed. The method used to place the focal plane at the correct focal position is described, since they make use of MTF measurements. Relative LOS measurements are done by theodolite measurements of the telescope. Qualitative ground test result of end-to-end imaging is given.

악조건하의 비동일평면 카메라 교정을 위한 알고리즘

  • Ahn, Taek-Jin;Lee, Moon-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.12
    • /
    • pp.1001-1008
    • /
    • 2001
  • This paper presents a new camera calibration algorithm for ill-conditioned cases in which the camera plane is nearly parallel to a set of non-coplanar calibration boards. for the ill-conditioned case, most of existing calibration approaches such as Tsais radial-alignment-constraint method cannot be applied. Recently, for the ill-conditioned coplanar calibration Lee&Lee[16] proposed an iterative algorithm based on the least square method. The non-coplanar calibration algorithm presented in this paper is an iterative two-stage procedure with extends the previous coplanar calibration algorithm. Through the first stage, camera, position and orientation parameters as well as one radial distortion factor are determined optimally for a given data of the scale factor and the focal length. In the second stage, the scale factor and the focal length are locally optimized. This process is repeated until any improvement cannot be expected any more Computational results are provided to show the performance of the algorithm developed.

  • PDF

PSD Sensor Module Based Monocular Motion Capture System (PSD센서모듈 기반 단안 모션캡쳐 시스템)

  • Kim, Yu-Geon;Ryu, Young-Kee;Oh, Choon-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.582-584
    • /
    • 2006
  • This paper describes a monocular PSD-based motion capture sensor to employ with commercial video game systems such as Microsoft's XBOX and Sony's Playstation II. The system compact, low-cost, and only requires a one-time calibration at the factory. The system includes a PSD(Position Sensitive Detector) and active infrared (IR) LED markers that are placed on the object to be tracked. The PSD sensor is placed in the focal plane of a wide-angle lens. The micro-controller calculates the 3D position of the markers using only the measured intensity and 2D position on the PSD. A series of experiments were performed to evaluate the performance of our prototype system. From the experimental results we see that the proposed system's compact size, low-cost, ease of installation, and high frame rates are suitable for high speed motion tracking in games.

  • PDF

Design and Performance Verification of a LWIR Zoom Camera for Drones

  • Kwang-Woo Park;Jonghwa Choi;Jian Kang
    • Current Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.354-361
    • /
    • 2023
  • We present the optical design and experimental verification of resolving performance of a 3× long wavelength infrared (LWIR) zoom camera for drones. The effective focal length of the system varies from 24.5 mm at the wide angle position to 75.1 mm at the telephoto position. The design specifications of the system were derived from ground resolved distance (GRD) to recognize 3 m × 6 m target at a distance of 1 km, at the telephoto position. To satisfy the system requirement, the aperture (f-number) of the system is taken as F/1.6 and the final modulation transfer function (MTF) should be higher than 0.1 (10%). The measured MTF in the laboratory was 0.127 (12.7%), exceeds the system requirement. Outdoor targets were used to verify the comprehensive performance of the system. The system resolved 4-bar targets corresponding to the spatial resolution at the distance of 1 km, 1.4 km and 2 km.

Analysis of Vibration and Its Break Efficiency Due to Focal Position Induced by Piezoelectric Extracorporeal Shock Wave Lithotripter (압전식 ESWL장치를 사용한 대상물 진동시 초점위치에 따른 진동 및 파쇄효율의 분석)

  • 장윤석
    • Proceedings of the IEEK Conference
    • /
    • 2000.06d
    • /
    • pp.186-189
    • /
    • 2000
  • In this paper, the relation between the vibration and the sound radiated due to the piezoelectric ESWL (Extra-corporeal Shock Wave Lithotripter) is examined And the relation between the focus and the vibration of the objects is examined. The same experiments with the objects that can be breton are done and the relation between the vibration and the break efficiency of the phantom is experimentally investigated. These results show that the relativity between the power of the peak frequency and the break efficiency can be confirmed.

  • PDF

실시간 전자거리인식을 위한 3차원거리계측 알고리즘

  • Kim, Jong-Man;Sin, Dong-Yong;Lee, Hye-Jeong;Kim, Hyeong-Seok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.5-5
    • /
    • 2010
  • The depth of the object pointed by the laser beam is computed depending on the pixel position on the CCD There involved several number of internal and external parameters such as inter-pixel distance, focal length, position and orientation of the system components in the depth measurement error. In this paper, it is shown through the error sensitivity analysis of the parameters that the most important parameters in the sense of error sources are the angle of the laser beam and the inter pixel distance. Also, the calibration technique to minimize their effect for the depth computation is proposed.

  • PDF

Effect of Process Parameters on Bead Formation in Nd:YAG Laser Welding of Thin Steels (저탄소 박판 강재의 Nd:YAG 레이저 용접부 형성에 미치는 공정변수의 영향)

  • 김기철;허재협
    • Journal of Welding and Joining
    • /
    • v.19 no.3
    • /
    • pp.317-324
    • /
    • 2001
  • This study deals with high power Nd:YAG laser welding of thin steels for small pressure vessels. Full penetration welding at the overlap joint was performed so as to assure sufficient weld strength. Results showed that mid-depth weld size reduced drastically with increasing the travel speed. Position of focus had little effect on the bead formation even though short focal system was used. However, the shape factor and the bead width had closely related with the position of focus. Based on the microstructural inspection, acceptable weld was obtained when the overlap clearance was controlled up to 20% of the base metal thickness. In the case that the joint contained more clearance than the critical value, both the tensile shear strength and the tear strength were reduced. Results also demonstrated that shielding gases were proved to play a key role as far as the bead formation characteristics was taken into consideration. Blowing dry air through 5mm in diameter nozzle produced narrower bead cross-section than that of argon or nitrogen shielding.

  • PDF

A Study on the Estimation of Camera Calibration Parameters using Cooresponding Points Method (점 대응 기법을 이용한 카메라의 교정 파라미터 추정에 관한 연구)

  • Choi, Seong-Gu;Go, Hyun-Min;Rho, Do-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.4
    • /
    • pp.161-167
    • /
    • 2001
  • Camera calibration is very important problem in 3D measurement using vision system. In this paper is proposed the simple method for camera calibration. It is designed that uses the principle of vanishing points and the concept of corresponding points extracted from the parallel line pairs. Conventional methods are necessary for 4 reference points in one frame. But we proposed has need for only 2 reference points to estimate vanishing points. It has to calculate camera parameters, focal length, camera attitude and position. Our experiment shows the validity and the usability from the result that absolute error of attitude and position is in $10^{-2}$.

  • PDF

Design of an 8× Four-group Zoom System without a Moving Group by Considering the Overall Length

  • Park, Sung Min;Lee, Jea-Woo;Park, Sung-Chan
    • Current Optics and Photonics
    • /
    • v.6 no.1
    • /
    • pp.104-113
    • /
    • 2022
  • We present a method to count the overall length of the zoom system in an initial design stage. In a zoom-lens design using the concept of the group, it has been very hard to precisely estimate the overall length at all zoom positions through the previous paraxial studies. To solve this difficulty, we introduce Teq as a measure of the total track length in an equivalent zoom system, which can be found from the first order parameters obtained by solving the zoom equations. Among many solutions, the parameters that provide the smallest Teq are selected to construct a compact initial zoom system. Also, to obtain an 8× four-group zoom system without moving groups, tunable polymer lenses (TPLs) have been introduced as a variator and a compensator. The final designed zoom lens has a short overall length of 29.99 mm, even over a wide focal-length range of 4-31 mm, and an f-number of F/3.5 at wide to F/4.5 at tele position, respectively.