• Title/Summary/Keyword: Focal Position

Search Result 142, Processing Time 0.03 seconds

Analysis of surface-relief profile for TPHK(Telecentric Paraxial Holographic Kinoform) as a fourier-transform lens using exact raytracking (광선추적법에 의한 푸리에변환 렌즈로서의 TPHK(Telecentric Paraxial Holographic Kinoform)의 표면양각형태에 대한 분석)

  • 김성우;조두진
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.2
    • /
    • pp.51-58
    • /
    • 1998
  • We investigated surface-relief profiles of the TPHK(telecentric paraxial holographic kinofrm) used as a Fourier-transform lens employing exact geometrical raytracing. For the TPHK of F/8 and focal length of 15 mm, we consider the cases where the thickness of the substrate is 0 and 50 ${\mu}{\textrm}{m}$, dividing the surface-relif profiles into fifty steps from plano-convex to convexplano shapes and varying the angle of incidence($0^{\circ},{2.5}^{\circ},5^{\circ}$). In order to identify appropriate surface-relief profiles, we employ, as criteria of performance, rms spot size, rms deviation from $f{\sin}{\theta}$, peak position and FWHM(full width at half maximum), number of rays abandoned from raytracing etc., which are determined from the result of exact raytracing. It is found that the profile with 80% of its relief thickness facing the image plane gives the best performance regardless of the presence of substrate.

  • PDF

The Concepts of Montage in Somatosensory Evoked Potentials (체성감각 유발 전위에서 montage에 대한 개념)

  • Cha, Jae-Kwan;Kim, Seung-Hyun
    • Annals of Clinical Neurophysiology
    • /
    • v.1 no.2
    • /
    • pp.160-167
    • /
    • 1999
  • Although somatosensory evoked potentials(SSEPs) have been utilized as the useful diagnostic tools in evaluating the wide variety of pathological conditions, such as focal lesions affecting the somatosensory pathways, demyelinating diseases, and detecting the clinically occult abnormality, their neural generators is still considerably uncertain. To appreciate the basis for uncertainties about the origins of SSEPs, consider criteria that must be met to establish a causal relationship between activity in a neural structure and a spine/ scalp-recorded potential. Electrode locations and channel derivations for SSEPs recordings are based on two principles:(1) the waveforms are best recorded from electrode sites on the body surface closest to the presumed generator sources along the somatosensory pathways, and(2) studies of the potential-field distribution of each waveform of interest dictate the best techniques to be used. In this article, authors will describe followings focused on ;(1) the concepts of near field potentials(NFPs) and far field potentials(FFPs) - the voltage of NFPs is highly dependent upon recording electrode position, FFPs are unlike NFPs in that they are widely distributed, their latencies and amplitudes are independent of recording electrode.(2) appropriate montage settings to detect the significant potentials in the median nerve and posterior tibial nerve SSEPs(3) neural generators of various potentials(P9, N13, P14, N18, N20, P37) and their clinical significance in interpretating the results of SSEPs. Especially, Characteristics of N18(longduration, small superimposed inflection) suggested that N18 is a complex wave with multiple generators including brainstem structures and thalamic nuclei. And N18 might be used as the parameter of braindeath. Precise understanding on these facts provide an adequate basis utilizing SSEPs for numerous clinical purposes.

  • PDF

Continuous pulse width variable quenched dye laser (펄스폭 연속가변 Quenched Dye Laser)

  • 황선우;이영주;김성훈;최종운
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.2
    • /
    • pp.152-156
    • /
    • 1999
  • We have developed the pulse-width variable Quenched Dye Laser (QDL). QDL consisted of the dye cell of 5 mm length containing a $2.5{\times}10^{-3}$[mol/l] solution of Rhodamine 6G and the cylindrical lens focal length of 150 mm and quenching mirror. QDL system was pumped by s XeCl excimer laser with 150 mJ pulse energy in a 20 ns pulse at 1 Hz repetition rate. Pulse-width of QDL was measured by a noncollinear intensity autocorrelator. The focused thckness was measured by changing the position of the focusing cylindrical lens. Pulse-width of QDL as a function of the focused thickness (273.0${\mu}{\textrm}{m}$~845.0${\mu}{\textrm}{m}$) varied continuously from 86 ps to 201 ps.

  • PDF

Fabrication of 365 nm Wavelength High Transmittance Silicone Resin TIR Lens and High Directivity Light Source Module for Exposure System (365 nm 파장대역 고투과율 실리콘 수지 TIR 렌즈 및 고지향성 노광기 광원모듈 제작)

  • Sung, Jun Ho;Yu, Soon Jae;Anil, Kawan;Jung, Mee Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.4
    • /
    • pp.267-271
    • /
    • 2018
  • A high directivity TIR (total internal reflection) lens in the UV-A region was designed using a silicone resin, and a UV light source module with a maximum irradiation density of $150mW/cm^2$ was fabricated. The beam angle of the TIR lens was designed to be $8.04^{\circ}$ and the maximum diameter of the TIR lens was Ø13.5. A silicone resin having a UV transmittance of 93% and a refractive index of 1.4 at a wavelength of 365 nm was used, and the lens was manufactured using an aluminum mold, from which silicone could be easily released. The module was fabricated in a metal printed circuit board of COB (chip on board) type using a $0.75{\times}0.75mm^2$ UV chip. A jig was used to adjust the focal length between lens and chip and to fix the position of the lens. The optical characteristics such as illumination distributions of the lens and module were designed using 'LightTools' optical simulation software. The heat dissipation system was designed to use a forced-air cooling method using a heat-sink and fan.

Computer Simulation for Development of Micro-Focus X-ray Generator (미소초점엑스선원 개발을 위한 전산모사)

  • Kim, Sung-Soo;Lee, Youn-Seoung;Kim, Do-Yun;Ko, Dong-Seob
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.6
    • /
    • pp.403-408
    • /
    • 2011
  • To develop the MFX (Micro-Focus X-ray) tube, the trajectories of electrons emitted from the field emission cathode was simulated using SIMION program. Regardless of starting position of the electron in emitter, we found out the fact that there is the optimum extractor voltage Ve, which can focus the electron beam on one place. Extractor voltage Ve varies depending on the source voltage Vs, but the ratio of two voltages (Ve/Vs) is always constant, its value was 99.4%. When the ratio of two voltages (Ve/Vs) was 99.4%, the beam diameter in the cross-over point was $1.2{\mu}m$. Because the focal spot size in MFXG (Micro-Focus X-ray Generator) can not be less than the cross-over diameter within MFX tube, it is important to find out the conditions that can make a smaller beam diameter. Therefore, the above results is considered to be a very important ones in the development of the MFXG.

Automatic Target Recognition for Camera Calibration (카메라 캘리브레이션을 위한 자동 타겟 인식)

  • Kim, Eui Myoung;Kwon, Sang Il
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.6
    • /
    • pp.525-534
    • /
    • 2018
  • Camera calibration is the process of determining the parameters such as the focal length of a camera, the position of a principal point, and lens distortions. For this purpose, images of checkerboard have been mainly used. When targets were automatically recognized in checkerboard image, the existing studies had limitations in that the user should have a good understanding of the input parameters for recognizing the target or that all checkerboard should appear in the image. In this study, a methodology for automatic target recognition was proposed. In this method, even if only a part of the checkerboard image was captured using rectangles including eight blobs, four each at the central portion and the outer portion of the checkerboard, the index of the target can be automatically assigned. In addition, there is no need for input parameters. In this study, three conditions were used to automatically extract the center point of the checkerboard target: the distortion of black and white pattern, the frequency of edge change, and the ratio of black and white pixels. Also, the direction and numbering of the checkerboard targets were made with blobs. Through experiments on two types of checkerboards, it was possible to automatically recognize checkerboard targets within a minute for 36 images.

Effects of oscillation parameters on aerodynamic behavior of a rectangular 5:1 cylinder near resonance frequency

  • Pengcheng Zou;Shuyang Cao;Jinxin Cao
    • Wind and Structures
    • /
    • v.38 no.1
    • /
    • pp.59-74
    • /
    • 2024
  • Large Eddy Simulation (LES) is used to explore the influence of vibration frequency and amplitude on the aerodynamic performance of a rectangular cylinder with an aspect ratio of B/D=5 (B: breadth; D: depth of cylinder) at a Reynolds number of 22,000 near resonance frequency. In smooth flow conditions, the research employs a sequence of three-dimensional simulations under forced vibration with diverse frequency ratios fe / fo = 0.8-1.2 (fe : oscillation frequency; fo : Strouhal frequency when the rectangular cylinder is stationary ) and oscillation amplitudes Ah/D = 0.05 - 0.3. The individual influences of fe / fo and Ah/D on the characteristics of integrated and distributed aerodynamic forces are the focal points of discussion. For the integrated aerodynamic force, particular emphasis is placed on the analysis of the dependence of velocity-proportional component C1 and displacement-proportional component C2 of unsteady aerodynamic force on amplitude and frequency ratio. Near the resonance frequency, the dependencies of C1 and C2 on amplitude are stronger than that of frequency ratio. For the distributed aerodynamic force, the increase in frequency and amplitude promotes the position of the main vortex core and reattachment to the leading edge in the streamwise direction. In the spanwise direction, vibration enhances the spanwise correlation of aerodynamic force to weaken the three-dimensional effect of the flow field, and a lower frequency ratio and larger amplitude amplify this effect.

Changes of lateral cephalometric values according to the rotation of head (두부회전에 따른 측모두부방사선 계측치의 변화)

  • Kim, Kwang-Soo;Hwang, Mee-Sun;Choi, Eui-Hwan;Kim, Kwang-Won;Yoon, Young-Jooh
    • The korean journal of orthodontics
    • /
    • v.30 no.1 s.78
    • /
    • pp.53-66
    • /
    • 2000
  • This study was performed to find out the effect of projection errors on cephalometric linear and angular measurements according to head rotation during taking lateral cephalometric radiographs. Seventeen skulls with permanent dentition and no gross asymmetry were obtained from the Department of Anatomy, Medical School, Chosun University. Total 527 x-ray films were taken with $1^{\circ}$ interval from the reference position($0^{\circ}$) to ${\pm}15^{\circ}$ around the vertical axis (Z axis) which is perpendicular to the midpoint of the line connecting the center of two ear rods in submento-vertex direction. Statistical analysis was performed by paired t-test if there were statistically significant differences between the mean of the reference position($0^{\circ}$) and that of each rotation angle. The following results were obtained. 1. The projection errors of angular measurements were smaller than those of linear measurements. 2. The projection errors of angular measurements including midline landmarks were smaller than those including bilateral landmarks. 3. The horizontal linear measurements were gradually decreased when the stroll was rotated toward the film, but slightly increased and then decreased when the skull was rotated toward the focal spot. However, the changes were smaller in focal direction. 4. The projection errors of horizontal linear measurements were larger than those of vertical linear measurements. 5. The projection errors of vertical linear measurements were increased with increased distance from the rotation axis to vertical measurements. It is concluded that the use of angular measurements rather than linear measurements is recommended to minimize the projection errors.

  • PDF

Measurement of Regional Cerebral Blood Volume in Normal Rabbits on Perfusion-weighted MR Image (MR 관류강조영상에서 정상 가토의 국소 뇌혈류량 측정)

  • 박병래;예수영;나상옥;김학진;이석홍;전계록
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.100-106
    • /
    • 2000
  • Purpose : To evaluate the usefulness of cerebral blood flow measurement applied to perfusion weighted image with short-scan time single shot gradient echo-planar technique in measuring cerebral blood volume(rCBV) of normal rabbits. Materials and methods : With 2.1-3.6 kg weighted rabbits, image is acquired when they are in supine position in children positioner. Perfusion weighted image is acquired to 44 seconds per 1 second successively. After 4 seconds later, Gd-DTPA 2ml are injected into int. jugular vein with 2 ml per second and normal saline is also injected after that. Same technique is applied 2 times per 30 minites in same rabbit. After Image is obtained in two part of cerebral cortex at vertex, convexity, in one of basal ganglia with choosing about $3-5{\textrm{mm}^2}$ areas. Curve of signal intensity changes in time sequence is drawn. After this images are transmitted by PC and software IDL, regional cerebral blood volume is measured with imaging processing program made by us. Results : With 22 of 24 rabbits, satisfactory 1-2 signal intensity versus time curve is made. Cerebral blood capacity and contrast media stay time (ST) is measured in two cerebral cortex and basal ganglia refering in parietal cerebral cortex. Mean focal cerebral blood flow capacity ratio in cortex was $0.97{\pm}0.35$ and in basal ganglia, $0.99{\pm}0.37$, mean contrast media stay time in cortex was $9.83{\pm}1.63$ sec and in basal gaiglia, $9.42{\pm}1.14$ sec, but there was no statistically significant difference between two areas ($\rho$=0.05). Conclusion : In cerebral cortex and basal ganglia, there is no difference in mean focal blood volume and mean contrast stay time. Therefore, PWI is useful in cerebral blood flow and early diagnosis, prognosis of cerebral ischemic disease. Hereafter, it is helpful in analysing cerebral blood flow changes with comparison difference in rCBV between normal tissue and ischemic tissue, and that with DWI finding in infarcted patient.

  • PDF

Pathological Studies on the Experimentally Induced Rodenticide Poisoning in Ruminant (반추수(反芻獸)의 살서제중독(殺鼠劑中毒)에 관한 병리학적(病理學的) 연구(硏究))

  • Lee, Cha-Soo;Park, Cheong-Kyu;Cho, Yong-Joon;Kwak, Soo-Dong
    • Korean Journal of Veterinary Research
    • /
    • v.22 no.2
    • /
    • pp.221-232
    • /
    • 1982
  • This paper dealt with the pathological and clinical findings on the experimentally induced rodenticide (fluoroacetate, zinc phosphide, thallium sulfate, coumarin) and NaCN poisoning of ruminants (Holstein cattle and/or Korean native goat) for the purpose of the diagnosis in the accidental rodenticide poisoning of cattle. The results observed are summarized as follows: Fluoroacetate poisoning (cattle and goat): in the clinical signs, there were depression, convulsion, dyspnea, groan, grinding of the teeth, vomiting, opisthotonus and post-mortem tympany. In the macroscopical findings, the blood was more or less poor coagulative and dark red, bloody fluid with foam in the trachea, hyperemia and hemorrhage of tracheal mucosa and lung, cloudy swelling and hyperemia of kidney, epicardial hemorrhage(cattle), and hyperemia of abomasum, intestine and brain were observed. In the microscopical findings, there were pulmonary edema and hemorrhage, necrosis of convoluted tubular epithelium and interstitial hemorrhage of kidney, focal coagulative necrosis of myocardium, hemorrhage of pancreas and spleen, dilatation of Virchow-Robin space and hyperemia of brain, and necrosis with desquamation of mucosal epithelia of abomasum and upper small intestine. In the histological lesions of the liver, lobular peripheral hyperemia, centrilobular necrosis and cytoplasmic inclusion bodies of the hetatic cells were observed. The cytoplasmic inclusion body of the hepatic cells was not seen in the affected goat, but hydropic degeneration of the hepatic cells was marked. Zinc phosphide poisoning (cattle and goat): clinically, the affected animals died in recumbent position after ataxia, dyspnea and convulsion. In the macroscopical findings, hyperemia and hemorrhage of lung, cloudy swelling and hyperemia of liver and kidney, hemorrhage of spleen (cattle), and catarrh of abomasum and small intestine were observed. In the microscopical findings, necrosis of the convoluted tubular epithelium and hyperemia of kidney, hemorrhage of spleen, hyperemia of lung, hyperemia or hemorrhage of heart, cloudy. swelling and fatty changes of hepatic cells, dilatation of hepatic central vein, hyperemia of brain, and catarrh of abomasal and small intestinal mucosae were observed. Thallium sulfate poisoning (cattle): in the macroscopical findings dark red color of blood, hyperemia and hemorrhage of lung, bloody fluid with foam in the tracheal mucosa, petechiae of tracheal mucosa, cloudy swelling and hemorrhage of liver, necrotic lesions and hemorrhage of renal cortex and epicardial hemorrhage were observed. In the microscopical findings, severe hemorrhages of the lung, cloudy swelling and necrosis of hepatic cells, hyperemia and hemorrhage of liver, focal coagulative necrosis of mycordium, necrosis of the convoluted tubular epithelium and hyperemia of kidney, hyperemia and hemorrhage of spleen and dilatation of Virchow-Robin apace in brain were observed. Coumarin poisoning (goat): the poisoned animals died in the state of groan and depression. In the macroscopical findings, poor coagulation of blood, hemorrhage of lung, cloudy swelling and severe hemorrhages of liver, cloudy swelling and hemorrhage of kidney, abomasal hemorrhage, catarrh of small intestine, and hyperemia and hemorrhage of the other organs were observed, In the microscopical findings, hyperemia and hemorrhage of lung and kidney, cloudy swelling of the convoluted tubular epithelium of kidney, severe hepatic hyperemia, cloudy swelling and hydropic degeneration of heptatic cell, and hyperemia and hemorrhage of brain and spleen were observed. NaCN poisoning (cattle and goat): clinically, there were convulsion, severe dyspnea, paresis of hind limb, depression and then rigor of four limbs. In the macroscopical findings, bright red color of blood, hyperemia and bright and red tinge of lung cloudy swelling of kidney and liver, and hyperemia of abomasum were observed. In the microscopical findings, cloudy swelling and hydropic degeneration of hepatic cell, hyperemia and edema of lung, necrosis and degeneration of the convoluted tubular epithelium and hemorrhage in kidney, dilatation of Virchow-Robin space of brain and hemorrhage of spleen were observed.

  • PDF