• Title/Summary/Keyword: Focal Depth

검색결과 150건 처리시간 0.031초

복부 일반촬영시 초점-필름간거리 변화가 피폭선량 및 화질에 미치는 영향 (Effects on Patient Exposure Dose and Image Quality by Increasing Focal Film Distance in Abdominal Radiography)

  • 김유현;권수일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권1호
    • /
    • pp.52-58
    • /
    • 1998
  • We can and must improve the diagnostic images using available knowledge and technology. At the same time we must strive to reduce the patient's integral and entrance radiation dose. Reducing the integral dose to the patient during the radiologic procedure is a primary concern of the patient, especially the pediatric patient, the radiologist and the technologist. A 100cm focal film distance generally is used for most over-table radiography. The early x-ray tubes and screen film combinations required long exposures, which often resulted in motion artifacts. But nowaday, we have the generators and x-ray tubes that can deliver the energy necessary in a very short time and the receptors that can record the information just as rapidly. And, we performed this studies to evaluate the patient exposure dose and the image quality by increasing focal film distance in diagnostic radiography. There are many factors which affected to exposure factor, but we studied to verify of FFD increase, only. Effect of increasing the focal film distance to a 140 cm distance was tested as follows; 1. The focal film distances were set at 100, 120, and 140cm. 2. A 18cm acryl(tissue equivalent) phantom was placed on the table top. 3. An Capintec 192 electrometer with PM 05 ion chamber was placed at the entrance surface of the phantom, and exposure were made at each focal film distances. 4. The procedure was repeated in the same manner as above except the ion chamber was placed beneath the phantom at the film plane. 5. Exit exposure were normalize to 8mR for each portions of the experiment. Based on the success of the empirical measurements, a detailed mathematical analysis of the dose reduction was performed using the percent depth dose data. The results of this study can be summerized as followings ; 1) Increasing FFD from 100 cm to 140 cm, we would create a situation that would have a significant effect on the overall quality of radiograph and achive the 17.42% reduction of entrance dose and the 18.95% reduction of integral dose that the patient receives. 2) Thickness of Al step wedge for equal film density increased with the long distance. 3) Increasing FFD, Magnification of image was lowered. 4) Resolution of image also increased with the FFD. As the results described above, we strongly recommend using the long FFD to provide better information for our patients and profession in abdomen radiographic studies.

  • PDF

Linking Species with the Ecosystem: The Emergence of Big Data and Artificial Intelligence in Ecological Research

  • Ohseok Kwon
    • Proceedings of the National Institute of Ecology of the Republic of Korea
    • /
    • 제4권4호
    • /
    • pp.135-140
    • /
    • 2023
  • The intricate relationship between species and their ecosystems has been a focal point of ecological research for decades. With the advent of big data and artificial intelligence, we are now able to explore this relationship with unprecedented depth and precision. This review delves into the transformative role of these technologies in ecological research, emphasizing their potential to enhance our understanding of species-ecosystem linkages.

Laser Welding Quality Monitoring with an Optical Fiber System

  • Kim, Jin-Tae;Kim, Do-Hyoung;Chung, Chin-Man;Baik, Sung-Hoon;Park, Seung-Kyu;Kim, Min-Suk
    • Journal of the Optical Society of Korea
    • /
    • 제7권3호
    • /
    • pp.193-196
    • /
    • 2003
  • We have developed a laser welding monitoring system to monitor laser welding process conditions such as sample feed rate, laser focal position, and laser power. A 2 ㎾ Nd:YAG CW laser beam has been applied to the welding of a stainless steel plate (SUS306) to investigate the welding monitoring. Theradiation signal from the weld pool was guided back through the focusing optics and the laser delivery fiber, and measured by a photo detector. By changing the focus of the laser beam along the z-direction, the penetration depth of the welding material has been measured. That shows the penetration depth depends on the frequency fluctuations of the plume signals which can be used in welding quality control.

거리 영상 측정 오차의 기하학적 분석 (A geometric analysis of range measurement error)

  • 윤강식;이병욱;박래홍
    • 한국통신학회논문지
    • /
    • 제22권6호
    • /
    • pp.1259-1265
    • /
    • 1997
  • 삼각측량의 원리를 이용하 거리 탐색기를 사용하여 거리 영상을 취득하는 경우에 발생하는 측정오차를 직관적으로 이해할 수 있도록 기하학적 방법으로 분석하였다. 그 결과로 추정 오차는 카메라에서 물체까지의 거리에 비례하는 것을 보였다. 또한 카메라 초점과 물체를 지나는 직선이 광원과 물체를 연결하는 직선과 직각인 경우 측정값이 가장 정밀한 것을 보였다. 또한 이 결과가 해석학의 기법을 사용하여 분석한 결과와 일치함을 보였고 실험을 통하여 이를 확인하였다. 본 연구 결과는 동일한 카메라가 광원을 사용한 경우에도 카메라의 방향과 물체까지의 거리를 변화시켜서 측정 정밀도를 향상시킬 수 있다는 것을 보인다.

  • PDF

An Analysis on the Range of Singular Fusion of Augmented Reality Devices

  • Lee, Hanul;Park, Minyoung;Lee, Hyeontaek;Choi, Hee-Jin
    • Current Optics and Photonics
    • /
    • 제4권6호
    • /
    • pp.540-544
    • /
    • 2020
  • Current two-dimensional (2D) augmented reality (AR) devices present virtual image and information to a fixed focal plane, regardless of the various locations of ambient objects of interest around the observer. This limitation can lead to a visual discomfort caused by misalignments between the view of the ambient object of interest and the visual representation on the AR device due to a failing of the singular fusion. Since the misalignment becomes more severe as the depth difference gets greater, it can hamper visual understanding of the scene, interfering with task performance of the viewer. Thus, we analyzed the range of singular fusion (RSF) of AR images within which viewers can perceive the shape of an object presented on two different depth planes without difficulty due to the failure of singular fusion. It is expected that our analysis can inspire the development of advanced AR systems with low visual discomfort.

변형된 삼각 및 마하젠더 간섭계 기반의 인코히어런트 홀로그래픽 3D 디스플레이 시스템의 광학적 구현 (Optical Implementation of Incoherent Holographic 3D Display System using Modified Triangular and Mach-Zehender Interferometer)

  • 김승철;구정식;김은수
    • 한국통신학회논문지
    • /
    • 제29권4C호
    • /
    • pp.524-532
    • /
    • 2004
  • 본 논문에서는 변형된 삼각 및 마하젠더 간섭계를 이용한 인코히어런트 홀로그래픽 3D 디스플레이 시스템의 광 입출력 장치를 구현하고 실험하였다. 먼저, 변형된 삼각 간섭계 기반의 광 입력장치를 구성하여 3차원 물체에 대한 인코히어런트 복소 홀로그램을 생성하고, LCD 공간광변조기와 위상 지연기가 추가된 마하젠더 간섭계 기반의 광 출력장치 구성을 통해 홀로그램의 실시간적 복원을 수행하였다. 즉, 100mm의 깊이감을 갖는 두 점광원에 대한 인코히어런트 홀로그램의 생성과 복원 실험을 통해 바이어스와 공액영상이 제거되고 초점에 따라 깊이감이 다른 두 영상의 복원이 가능함을 확인하였으며, 구현된 광 입출력 장치를 통해 서로 30 mm의 깊이감을 갖는 3차원 물체인 두개의 주사위에 대한 홀로그램을 실시간적으로 생성하고 복원시킴으로서 변형된 삼각 간섭계에 기반한 홀로그래픽 3차원 영상디스플레이 시스템의 광학적 구현 가능성을 제시하였다.

A second order analytical solution of focused wave group interacting with a vertical wall

  • Sun, Yonggang;Zhang, Xiantao
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권2호
    • /
    • pp.160-176
    • /
    • 2017
  • The interaction of focused wave groups with a vertical wall is investigated based on the second order potential theory. The NewWave theory, which represents the most probable surface elevation under a large crest, is adopted. The analytical solutions of the surface elevation, velocity potential and wave force exerted on the vertical wall are derived, up to the second order. Then, a parametric study is made on the interaction between nonlinear focused wave groups and a vertical wall by considering the effects of angles of incidence, wave steepness, focal positions, water depth, frequency bandwidth and the peak lifting factor. Results show that the wave force on the vertical wall for obliquely-incident wave groups is larger than that for normally-incident waves. The normalized peak crest of wave forces reduces with the increase of wave steepness. With the increase of the distance of focal positions from the vertical wall, the peak crest of surface elevation, although fluctuates, decreases gradually. Both the normalized peak crest and adjacent crest and trough of wave forces become larger for shallower water depth. For focused wave groups reflected by a vertical wall, the frequency bandwidth has little effects on the peak crest of wave elevation or forces, but the adjacent crest and trough become smaller for larger frequency bandwidth. There is no significant change of the peak crest and adjacent trough of surface elevation and wave forces for variation of the peak lifting factor. However, the adjacent crest increases with the increase of the peak lifting factor.

식약처에서 허가된 집속형 ESWT 치료기의 음향 출력 분석 (Inspection on the acoustic output of the focused extracorporeal focused shock wave therapeutic devices approved by MFDS)

  • 최민주;전성중;권오빈;이민영;조진식;김한수;맹은호
    • 한국음향학회지
    • /
    • 제39권4호
    • /
    • pp.303-317
    • /
    • 2020
  • 체외충격파치료술(Extracorporeal Shock Wave Therapy, ESWT)은 보존적인 치료가 어려운 근골격계 난치성 통증 치료 뿐 아니라 심혈관계 질환까지 적용 분야가 확대되고 있는 혁신적인 치료술이다. 본 연구에서는 국내에서 사용되는 집속형 ESWT 치료기의 성능을 결정하는 충격파 음향 출력의 분포를 조사했다. 분석에 사용된 데이터는 식약처에 등록된 30개 기술 문서를 통해 수집했다. 조사 결과, ESWT 치료기 충격파의 집속 특성은, 초점 거리가 5 mm ~ 65 mm, 초점 폭이 3 mm ~ 30 mm, 초점 깊이가 4 mm ~ 108 mm 범위에서 변화하고 있다. 충격파의 최대 양압(P+)는 7 MPa ~ 280 MPa, 초점에서 에너지 밀도 Energy Flux Density(EFD)는 0.0035 mJ/㎟ ~ 35 mJ/㎟, 펄스당 에너지(E)는 0.737 mJ ~ 80.86 mJ로 매우 넓은 범위에서 분포하고 있다. P+ 및 EFD 상관성 분석에 포함된 모든 국내산 PE 방식 제품(5개) 및 1개의 EM 방식 국산 치료기는 P+ 및 EFD가 통상적인 범위를 크게 벗어나고 있으며, 예상되는 상관성을 따르지 않고 있어, 데이터의 신뢰성을 인정하기 어려운 상태이다. 음향 출력의 값에 신뢰성을 부여하기 어려운 경우, 식약처에서 인정하는 시험 검사 기관을 통해 사후 시험 검사 및 관리가 요구된다. 충격파 음향 출력에 대한 통과 기준이 치료기의 적응증에 대한 임상 시험 결과를 근거로 설정될 수 있도록 식약처의 규정 및 가이드라인 개선이 필요하다.

1996년 12월 13일 ML 4.5 영월 지진의 지진원 상수 (Source parameters for the December 13 1996 ML 4.5 Earthquake in Yeongwol, South Korea)

  • 최호선
    • 한국지진공학회논문집
    • /
    • 제13권5호
    • /
    • pp.23-29
    • /
    • 2009
  • 1996년 12월 13일 강원도 영월군 지역에서 국지규모(M$_L$) 4.5의 지진이 발생하였다. 진앙은 37.2545$^{\circ}$N, 128.7277$^{\circ}$E이며, 지체구조구상 옥천습곡대에 해당한다. 지진자료의 필터링 대역에 따라 파형역산을 수행하였는데, 0.02$\sim$0.2 Hz 필터링 대역을 적용할 경우 진원 깊이는 6 km, 지진모멘트는 1.3$\times$10$^{16}$ N$\cdot$m로 추정되었다. 이 지진모멘트는 모멘트규모(M$_W$) 4.7에 해당한다. 파형역산과 P파의 초동 극성 분석을 통한 영월 지진의 발진기구는 역단층 성분을 포함한 주향이동단층 특성을 보이며, 주응력 방향은 동북동-서남서 방향이다. 스펙트럼 분석을 통해 추정된 모멘트규모는 4.8이며, 이는 파형역산에 의해 추정된 모멘트규모와 비슷하다. 평균 응력강하는 14.3 MPa로 추정되었다.

한반도의 소규모지진 모멘트 텐서 역산의 응용 (Application of Moment Tensor Inversion to Small Local Earthquakes in the Korean Peninsula)

  • 김소구;판티김반;이승규
    • 한국방재학회 논문집
    • /
    • 제1권3호
    • /
    • pp.123-136
    • /
    • 2001
  • 모멘트 텐서 역산의 응용 목적은 지진 메커니즘, 지진 모멘트, 한반도에서 국지적으로 발생하는 규모 5.5 이하의 소규모 지진의 진원깊이 등의 진원인자를 결정하는 것이다. 이와 같이 광범위한 지형에서 발생하는 지진들은 어느 지역에서의 활동적인 지체구조를 밝혀내는 실마리를 제공해 준다. 더욱이 소규모 지진의 지진 메커니즘 연구를 위해서는 반드시 필요하다. 본 논문에서는 한반도에서 최근에 발생한 규모 3.3 - 4.8의 14개 지진을 모멘트 역산방법 (TDMT_INV)을 이용하여 지진 메커니즘 분석 결과를 소개하고 있다. 단층들의 주향은 북동-남서, 북서-남동 방향으로 주향이동 또는 소규모 역단층의 주향이동 단층을 보이고 있다. 응력장의 압축방향은 몇몇 단층을 제외하고는 동-서 또는 동북동-서남서 방향이 우세한 것으로 나타났다. 그리고 영남 육괴와 원산 지역에 분포하는 지진들은 남-북 또는 북북서-남남동 방향이 우세한 것으로 나타났다.

  • PDF