• 제목/요약/키워드: Flux-Locked Loop

검색결과 24건 처리시간 0.018초

사파이어 기판을 사용한 병렬 검출코일 구조의 계단형 모서리 접합 SQUID 자력계 (YBCO step-edge junction dc SQUID magnetometers with multi-loop pickup coil fabricated on sapphire substrates)

  • 황태종;김인선;김동호;박용기
    • Progress in Superconductivity
    • /
    • 제5권2호
    • /
    • pp.94-97
    • /
    • 2004
  • Step-edge Josephson junctions (SEJ) have been fabricated on sapphire substrates with in situ deposited films of CeO$_2$ buffer layer and YBa$_2$Cu$_3$O$_{7}$ films on the low angle steps. Direct coupled SQUID magnetometers with the SEJ were formed on 1 cm X 1 cm R-plane sapphire substrates. Typical 5-${\mu}{\textrm}{m}$-wide Josephson junctions have R$_{N}$ of 3 Ω and I$_{c}$ of 50 $mutextrm{A}$ at 77 K. The direct coupled SQUID magnetometers were designed to have pickup coils of 50-${\mu}{\textrm}{m}$-wide 16 parallel loops on the 1 cm X 1 cm substrates with outer dimension of 8.8 mm X 8.8 mm. The SEJ SQUID magnetometers exhibit relatively low 1/f noise even with dc bias control, and could be stably controlled by flux-locked loops in the magnetically disturbed environment. Field noise of the do SQUID was measured to be 200∼300 fT/Hz$^{1}$2/in the white noise region and about 2 pT/Hz$^{1}$2/ at 1 Hz when measured with dc bias method.hod.d.

  • PDF

DROS 자력계의 동작특성 및 심자도 측정 (The characteristics of DROS magnetometer and MCG measurement)

  • 강찬석;이용호;권혁찬;김진목;유권규;박용기;이순걸
    • Progress in Superconductivity
    • /
    • 제8권2호
    • /
    • pp.164-168
    • /
    • 2007
  • We developed a SQUID magnetometer based on Double Relaxation Oscillation SQUID(DROS) for measuring magnetocardiography(MCG). Since DROS provides a 10 times larger flux-to-voltage transfer coefficient than the conventional DC-SQUID, simple flux-locked loop electronics could be used for SQUID operation. Especially, we adopted an external feedback to eliminate the magnetic coupling with adjacent channels. When the DROS magnetometer was operated inside a magnetically shielded room, average magnetic field noise was about 5 $fT/^{\surd}Hz$ at 100 Hz. Using the DROS magnetometer, we constructed a multichannel MCG system. The system consisted of 61 magnetometers are arranged in a hexagonal structure and measures a vertical magnetic-field component to the chest surface. The distance between adjacent channels is 26 mm and the magnetometers cover a circular area with a diameter of 208 mm. We recorded the MCG signals with this system and confirmed the magnetic field distribution and the myocardinal current distribution.

  • PDF

A Low-noise Multichannel Magnetocardiogram System for the Diagnosis of Heart Electric Activity

  • Lee, Yong-Ho;Kim, Ki-Woong;Kim, Jin-Mok;Kwon, Hyuk-Chan;Yu, Kwon-Kyu;Kim, In-Seon;Park, Yong-Ki
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권4호
    • /
    • pp.154-163
    • /
    • 2006
  • A 64-channel magnetocardiogram (MCG) system using low-noise superconducting quantum interference device (SQUID) planar gradiometers was developed for the measurements of cardiac magnetic fields generated by the heart electric activity. Owing to high flux-to-voltage transfers of double relaxation oscillation SQUID (DROS) sensors, the flux-locked loop electronics for SQUID operation could be made simpler than that of conventional DC SQUIDs, and the SQUID control was done automatically through a fiber-optic cable. The pickup coils are first-order planar gradiometers with a baseline of 4 em. The insert has 64 planar gradiometers as the sensing channels and were arranged to measure MCG field components tangential to the chest surface. When the 64-channel insert was in operation everyday, the average boil-off rate of the dewar was 3.6 Lid. The noise spectrum of the SQUID planar gradiometer system was about 5 fT$_{rms}$/$\checkmark$Hz at 100 Hz, operated inside a moderately shielded room. The MCG measurements were done at a sampling rate of 500 Hz or 1 kHz, and realtime display of MCG traces and heart rate were displayed. After the acquisition, magnetic field mapping and current mapping could be done. From the magnetic and current information, parameters for the diagnosis of myocardial ischemia were evaluated to be compared with other diagnostic methods.

2 Hall-ICs를 이용한 Slotless PM Brushless DC Motor의 정밀속도제어를 위한 PLL 제어방식 (PLL Control Method for Precise Speed Control of Slotless PM Brushless DC Motor Using 2 Hall-ICs)

  • 윤용호;이승준;김영란;원충연;최유영
    • 전력전자학회논문지
    • /
    • 제10권2호
    • /
    • pp.109-116
    • /
    • 2005
  • 최근 각종 산업기기 및 자동화기기에는 회전자가 영구자석으로 구성된 브러시리스 전동기의 사용이 증가하고 있다. 그러나 회전자가 영구자석으로 이루어진 BLDC전동기의 경우 회전자 위치 판별 센서는 필수 요소이다. PM BLDC 전동기의 속도제어를 수행함에 있어 기존의 엔코더와 Hall-IC 3개를 이용하지 않고, 2개의 Hall-IC로 3상 motor의 나머지 한상의 Hall-IC 신호를 추정하였다. 또한 사용된 PM BLDC motor는 고속속도를 가지는 특성을 가지고 있지만 Hall-IC를 이용하여 속초제어를 하기 때문에 속도의 오차 량이 상당히 크다는 단점을 가지고 있다. 따라서 이러한 단점을 개선하기 위해 저가의 PLL회로를 적용하였다. 또한 실험을 통하여 그 타당성을 검증하였다.