Cooling Heat Transfer Characteristics of CO2 in Helical Coil Type Gas Coolers (헬리컬 코일형 가스냉각기 내 CO2의 냉각 열전달 특성)

  • Son, Chang-Hyo;Jeon, Min-Ju;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.699-706
    • /
    • 2007
  • The cooling heat transfer coefficient and pressure drop of $CO_2$(R-744) in helical coil copper tubes were investigated experimentally The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter. a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45 and 4.55mm inner diameter The refrigerant mass fluxes were varied from 200 to $600 [kg/m^2s]$ and the inlet pressures of 9as cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in helical coil tubes increase with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows a relatively food agreement with those Predicted by Ito's correlation developed for single-phase in helical coil tubes. Though a few correlation available with the data. the local heat transfer coefficient of $CO_2$ agrees well with those presented by Pitla et al. among the predictions. However at the region near pseudo-critical temperature. the experiment data indicate higher values than the Pitla et al. correlation.

Heat Transfer Characteristics of Inclined Helical Coil Type Heat Exchanger (경사진 헬리컬 코일 열교환기의 열전달 특성에 관한 연구)

  • Son, Chang-Hyo;Jeon, Min-Ju;Jang, Seong-Il;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.707-714
    • /
    • 2007
  • The heat transfer coefficient and Pressure drop during gas cooling process of $CO_2$ (R-744) in inclined helical coil copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver. a variable-speed pump. a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45mm inner diameter. The refrigerant mass fluxes were varied from 200 to $600[kg/m^2s]$ and the inlet Pressures of gas cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in the inclined helical coil tubes increases with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows a relatively good agreement with those Predicted by Ito's correlation developed for single-phase in a helical coil tube. The local heat transfer coefficient of $CO_2$ agrees well with the correlation by Pitla et al. However, at the region near pseudo-critical temperature. the experiments indicate higher values than the Pitla et al. correlation. Therefore. various experiments in the inclined helical coil tubes have to be conducted and it is necessary to develop the reliable and accurate prediction determining the heat transfer and pressure drop of $CO_2$ in the inclined helical coil tubes.

Prediction of Pollutant Emissions from Lean Premixed Gas Turbine Combustor Using Chemical Reactor Network (화학반응기 네트워크을 이용한 희박 예혼합 가스터빈 연소기에서의 오염물질 예측에 관한 연구)

  • Park, Jung-Kyu;Nguyen, Truc Huu;Lee, Min-Chul;Chung, Jae-Wha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.2
    • /
    • pp.225-232
    • /
    • 2012
  • A chemical reactor network (CRN) was developed for a lean premixed gas turbine combustor to predict the emission of pollutants such as NOx and CO. In this study, the predictions of NOx and CO emissions from lean premixed methane-air combustion in the gas turbine were carried out using CHEMKIN and a GRI 3.0 methane-air combustion mechanism, which includes the four NO formation mechanisms for various load conditions. The calculated results were compared with experimental data obtained from a modified test combustor to validate the model. The contributions of the four NO pathways were investigated for various load conditions. The effects of nonuniformity of the mass flux and of the equivalence ratio of the injector on the NOx formation were investigated, and a method of reducing the pollutant formation was suggested for the development of a sub-10 ppm gas turbine combustor.

Development and Application of the Ecosystem Model in Brackish Lake Obuchi, Japan (일본 기수호(Lake Obuchi)에서 생태계 모델의 개발과 적용)

  • Kondo, Kunio;Inaba, Jiro;Hosoda, Masahiro;Kutsukake, Hiroshi;Seike, Yasushi;Nakata, Kisaburo;Shinji, Ueda
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.4 s.109
    • /
    • pp.448-454
    • /
    • 2004
  • In order to evaluate the water quality (N, P and C) and the biological mass balance of semi-enclosed brackish Lake Obuchi, Japan, an ecosystem model was developed and applied to the lake, using the flow field calculated by a hydrodynamic model. The time series data of the observed tide level, river discharge and meteorological parameters from January 2001 to December 2002 were incorporated as the parameters of the hydrodynamic model. Water quality and biomass balance were estimated by the ecosystem model, and simulated fluctuations In water quality agreed with our observations. The carbon contents of POC, phytoplankton and zooplankton in the lake were calculated by the model at an average 7200, 1500 and 22 kg, respectively, which somewhat agreed with our observations of POC (5900 kg), phytoplankton (3800kg), and zooplankton (150kg).

Validation of FDS for the Pool Fires within Two Rooms (이중격실 Pool 화재에 대한 FDS 검증분석)

  • Bae, Young-Bum;Ryu, Su-Hyun;Kim, Yun-Il;Lee, Sang-Kyu;Keum, O-Hyun;Park, Jong-Seok
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.60-67
    • /
    • 2010
  • Fire model shall be verified and validated to reliably predict the consequences of fires within its limitations. Generally the verification and validation procedures are conducted by comparison with experimental test data. This study aims to evaluate predictive capabilities of FDS in the pool fire with two rooms and the sensitivity between input parameters such as heat release rate and ventilation rate and the output values like temperature, concentration, and heat flux. The predictive capabilities of FDS will be evaluated by comparing FDS simulation results with PRISME experimental data which result from the international fire test project. The sensitivity analysis will be conducted to decide which one of input parameters affects outcomes by comparison of FDS results with ${\pm}$ 10% changes of input parameter. From this study, the FDS predictive capabilities are within 20% error range. Heat release rate as input parameter affects most of outcomes and flow rate only has relation with concentration of oxygen and combustion products.

A Study on the Performance of the Heat Transfer for the Liquid Filling as the Ratio of Working Fluid Volume to Total Volume of the Thermosyphon with Axial Internal Fins (축방향 내부 핀을 가진 열사이폰의 작동유체 체적변화에 대한 열전달 성능에 관한 연구)

  • Lee, Jung-Han;Lee, Ki-Baik;Cho, Dong-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.1
    • /
    • pp.23-30
    • /
    • 2002
  • This study concerns the performance of the heat transfer of the thermosyphon having 80 internal fins in which boiling and condensation occur. Water has been used as the working fluid. The Liquid filling as the ratio of working fluid volume to total volume of thermosyphon have been used as the experimental parameters. The heat flux and heat transfer coefficient at the condenser are estimated from the experimental results. The experimental results have been assessed and compared with existing theories. As a result of the experimental investigation we can state that the maximum heat flow rate in the thermosyphon prove to depend upon the liquid fill quantity. The relatively high rates of heat transfer have been achived operating in the thermosyphon with axial internal fins. Also, the thermosyphon with internal micro fins can be used to achieve some inexpensive and compact heat exchangers in low temperature. In addition, it is to obtain the overall heat transfer coefficients and the characteristics as a operating temperature for the practical applications.

An Experimental Study on the Performance of a Concentrating Photovoltaic Cell as a Function of Temperature (온도에 따른 집광형 태양전지의 성능에 관한 실험적 연구)

  • Shin, Jae-Hyuk;Yi, Seung-Shin;Kim, Sang-Min;Boo, Joon-Hong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.96-101
    • /
    • 2012
  • An experimental study was conducted to investigate the performance of a concentrating photovoltaic cell (CPV) against temperature. It is know that a high efficiency of a CPV can be achieved only with proper cell temperature as well as high concentration ratio (CR). This study is concerned with appropriate cooling condition for a liquid-convection cooler for the best performance of a specific CPV. A series of experiments was conducted in a range of cell temperatures as a result of varying cooling conditions, while the concentration ratio was 390 and the solar irradiation flux was higher than 900 $W/m^2$ in outdoor environment. The CPV had a planar dimension of 10 by 10 mm. A Fresnel lens was used as a concentrator, of which the dimension was 221 mm(W) ${\times}$ 221 mm(L) ${\times}$ 3 mm(t) and the transmissivity was known to be 0.8. The cooler was attached to the bottom side of the CPV and had a contact area of 21 mm(W) ${\times}$ 26 mm(L), which was identical to the size of the base plate of the CPV. The coolant temperature was controlled by an isothermal bath and the flow rate was controlled and measured by a flowmeter. The experimental results showed that the average of power efficiency of the CPV decreased from 28.6 % to 24.7 % as the cell temperature increased from $36^{\circ}C$ to $97^{\circ}C$. An appropriate cooling method of a CPV might increase the power conversion efficiency by about 4% for the same concentration ratio. Discussion is included from the viewpoint of the combined efficiency in addition to the power efficiency.

  • PDF

Sensitivity Analyses for Maximum Heat Removal from Debris in the Lower Head

  • Kim, Yong-Hoon;Kune Y. Suh
    • Nuclear Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.395-409
    • /
    • 2000
  • Parametric studies were performed to assess the sensitivity in determining the maximum in-vessel heat removal capability from the core material relocated into the lower plenum of the reactor pressure vessel (RPV)during a core melt accident. A fraction of the sensible heat can be removed during the molten jet delivery from the core to the lower plenum, while the remaining sensible heat and the decay heat can be transported by rather complex mechanisms of the counter-current flow limitation (CCFL) and the critical heat flux (CHF)through the irregular, hemispherical gap that may be formed between the freezing oxidic debris and the overheated metallic RPV wall. It is shown that under the pressurized condition of 10MPa with the sensible heat loss being 50% for the reactors considered in this study, i.e. TMI-2, KORI-2 like, YGN-3&4 like and KNGR like reactors, the heat removal through the gap cooling mechanism was capable of ensuring the RPV integrity as much as 30% to 40% of the total core mass was relocated to the lower plenum. The sensitivity analysis indicated that the cooling rate of debris coupled with the sensible heat loss was a significant factor The newly proposed heat removal capability map (HRCM) clearly displays the critical factors in estimating the maximum heat removal from the debris in the lower plenum. This map can be used as a first-principle engineering tool to assess the RPV thermal integrity during a core melt accident. The predictive model also provided ith a reasonable explanation for the non-failure of the test vessel in the LAVA experiments performed at the Korea Atomic Energy Research Institute (KAERI), which apparently indicated a cooling effect of water ingression through the debris-to-vessel gap and the intra-debris pores and crevices.

  • PDF

Optical Fiber Daylighting System Combined with LED Lighting and CPV based on Stepped Thickness Waveguide for Indoor Lighting

  • Vu, Ngoc Hai;Shin, Seoyong
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.488-499
    • /
    • 2016
  • We present a design and optical simulation of a cost-effective hybrid daylighting/LED system composed of mixing sunlight and light-emitting diode (LED) illumination powered by renewable solar energy for indoor lighting. In this approach, the sunlight collected by the concentrator is split into visible and non-visible rays by a beam splitter. The proposed sunlight collector consists of a Fresnel lens array. The non-visible rays are absorbed by the solar photovoltaic devices to provide electrical power for the LEDs. The visible rays passing through the beam splitters are coupled to a stepped thickness waveguide (STW) by tilted mirrors and confined by total internal reflection (TIR). LEDs are integrated at the end of the STW to improve the lighting quality. LEDs’ light and sunlight are mixed in the waveguide and they are coupled into an optical fiber bundle for indoor illumination. An optical sensor and lighting control system are used to control the LED light flow to ensure that the total output flux for indoor lighting is a fixed value when the sunlight is inadequate. The daylighting capacity was modeled and simulated with a commercial ray tracing software (LighttoolsTM). Results show that the system can achieve 63.8% optical efficiency at geometrical concentration ratio of 630. A required accuracy of sun tracking system achieved more than ±0.5o . Therefore, our results provide an important breakthrough for the commercialization of large scale optical fiber daylighting systems that are faced with challenges related to high costs.

A Permeation Behavior for the Pervaporation of Aqueous Ethanol Solution (에탄올 수용액의 Pervaporation에서의 투과거동)

  • Bae, Seong-Youl;Lee, Han-Sun;Hwang, Seong-Min;Kim, Hee-Taik;Kumazawa, Hidehiro
    • Applied Chemistry for Engineering
    • /
    • v.5 no.1
    • /
    • pp.127-138
    • /
    • 1994
  • In the process of pervaporation separation for aqueous ethanol solution through cellulose tai-acetate(CTA) membrane, the modelling on the solution-diffusion permeation mechanism was built up on the basis of sorption and permeation experimental results. Also its function type and parameter were examined. The composition of sorption equilibrium in three component system(Ethanol/Water/CTA) were compared with the calculated value by Flory-Huggins' equation using the pure component sorption data. In order to apply the thermodynamic equilibrium relationship between the membrane free composition in the membrane and the equilibrium composition in the liquid phase, the apparent activity this system, however, the results were not satisfied. Diffusion equations were expressed with the concentration gradient considering permeate alone, and a concentration-dependent diffusion coefficient which includes a parameter was used. And this model was fitted with the measured permeation rates. If the permeation rate and the amount of sorption of one component were much larger than those of the other, the bulk flow term could not be negligible. The flux and selectivity were increased with increasing temperature, and with decreasing downstream pressure.

  • PDF