• 제목/요약/키워드: Flux-Barrier

검색결과 95건 처리시간 0.034초

Characteristics of tungsten coated graphite using vacuum plasma spraying method

  • Lim, Hyeonmi;Kang, Boram;Kim, Hoseok;Hong, Bong Guen
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.200.1-200.1
    • /
    • 2016
  • Tungsten coatings on the graphite (CX-2320) were successfully deposited using the vacuum plasma spraying (VPS) method. An optimum coating procedure was developed and coating thicknesses of $409{\mu}m$ (without an interlayer) and $378{\mu}m$ (with an interlayer) were obtained with no cracks and no signs of delamination. The mechanical characteristics and microstructure of the tungsten coating layers were investigated using a Vickers hardness tester, FE-SEM, EDS, and XRD. The effect of a titanium interlayer on the properties of the tungsten coating was investigated. It was shown that the titanium interlayer prevented the diffusion of carbon to the tungsten layer, thereby suppressing the formation of tungsten carbide. Vickers hardness data yielded values that were 62.5 ~ 80.46% of those for bulk tungsten, indicating that tungsten coatings on graphite can be utilized as a plasma-facing material. High heat flux tests were performed by using thermal plasma with a maximum flux of $10MW/^2$. Vickers hardness after the heat flux test is performed to see a change in the mechanical properties. The formationof a tungsten carbide and the effect of the titanium interlayer for the diffusion barrier are investigated by using energy dispersion spectroscopy (EDS).

  • PDF

Resonance tunneling phenomena by periodic potential in type-II superconductor

  • Lee, Yeong Seon;Kang, Byeongwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제16권1호
    • /
    • pp.1-5
    • /
    • 2014
  • We calculated the resonance tunneling energy band in the BCS gap for Type-II superconductor in which periodic potential is generated by external magnetic flux. In this model, penetrating magnetic flux was assumed to be in a fixed lattice state which is not moving by an external force. We observed the existence of two subbands when we used the same parameters as for the $Nd_{1.85}Ce_{0.15}CuO_X$ thin film experiment. The voltages at which the regions of negative differential resistivity (NDR) started after the resonant tunneling ended were in a good agreement with the experimental data in the field region of 1 T - 2.2 T, but not in the high field regions. Discrepancy occurred in the high field region is considered to be caused by that the potential barrier could not be maintained because the current induced by resonant tunneling exceeds the superconducting critical current. In order to have better agreement in the low field region, more concrete designing of the potential rather than a simple square well used in the calculation might be needed. Based on this result, we can predict an occurrence of the electromagnetic radiation of as much difference of energy caused by the 2nd order resonant tunneling in which electrons transit from the 2nd band to the 1st band in the potential wells.

자속 장벽에 의한 IPMSM의 온도 상승 억제 효과 (Temperature Rising Suppression Effect of IPMSM by the Flux Barrier)

  • 조을규;조광진;김규탁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.780-781
    • /
    • 2015
  • 영구자석 전동기(PMSM)의 온도 상승은 권선 저항 증가에 의한 동손 증가와 희토류 계열 영구자석의 성능 저하, 고온 불가역감자 등의 원인이 되기 때문에 전동기의 성능이 저하되고 수명이 단축된다. 따라서 본 논문에서는 영구자석의 온도 상승 억제를 위하여 자속 장벽을 설치하고, 이를 열 등가회로망으로 열 해석을 수행하였다.

  • PDF

Thermal Behavior Variations in Coating Thickness Using Pulse Phase Thermography

  • Ranjit, Shrestha;Chung, Yoonjae;Kim, Wontae
    • 비파괴검사학회지
    • /
    • 제36권4호
    • /
    • pp.259-265
    • /
    • 2016
  • This paper presents a study on the use of pulsed phase thermography in the measurement of thermal barrier coating thickness with a numerical simulation. A multilayer heat transfer model was ussed to analyze the surface temperature response acquired from one-sided pulsed thermal imaging. The test sample comprised four layers: the metal substrate, bond coat, thermally grown oxide and the top coat. The finite element software, ANSYS, was used to model and predict the temperature distribution in the test sample under an imposed heat flux on the exterior of the TBC. The phase image was computed with the use of the software MATLAB and Thermofit Pro using a Fourier transform. The relationship between the coating thickness and the corresponding phase angle was then established with the coating thickness being expressed as a function of the phase angle. The method is successfully applied to measure the coating thickness that varied from 0.25 mm to 1.5 mm.

Diffusion Coefficients and Membrane Potential within Carrier Membrane by Reverse Transport System

  • Yang, Wong-Kang;Jeong, Sung-Hyun;Lee, Won-Chul
    • Korean Membrane Journal
    • /
    • 제4권1호
    • /
    • pp.36-40
    • /
    • 2002
  • The diffusion coefficients of ions in the reverse transport system using the carrier mediated membrane were estimated from the diffusional membrane permeabilities and the ion activity in membrane system. In the aqueous alkali metal ions-membrane system diffusional flux of alkali metal ions driven by coupled proton was analyzed. The aqueous phase I contained NaOH solution and the aqueous phase II also contained NaCl and HCl mixed solution. The concentration of Na ions of both phases were $10^{0},\;10^{-1},\;10^{-2},\;5{\times}10^{-1}\;and\;5{\times}10^{-2}\;mol{\cdot}dm^{-3}$ and the concentration of HCI in aqueous phase II was always kept at $1{\times}10^{-1}\;mol{\cdot}dm^{-3}$. Moreover, the carrier concentration in liquid membrane was $10^{-2}\;mol{\cdot}dm^{-3}$. The results indicated that the diffusion coefficients depend strongly on the concentration of both phases electrolyte solution equilibriated with the membrane. The points were interpreted in terms of the energy barrier theory. Furthermore, eliminating the potential terms from the membrane equation was derived.

Enhanced Skin Permeation of a New Capsaicin Derivative (DA-5018) from a Binary Vehicle System Composed of Isopropyl-myristate and Ethoxydiglycol

  • Cha, Bong-Jin;Lee, Eung-Doo;Kim, Won-Bae;Chung, Suk-Jae;Lee, Min-Hwa;Shim, Chang-Koo
    • Archives of Pharmacal Research
    • /
    • 제24권3호
    • /
    • pp.224-228
    • /
    • 2001
  • DA-5018, a recently synthesized capsaicin analog, appears to possess potent analgesic activity when administered topically. The objective of this study is to test the feasibility of the topical administration of this compound. Specifically, our goal was to identify vehicle system that permit a reasonable transdermal permeation of the compound in mice. Among the vehicles examined, isopropyl myristate (IPM) showed the largest in vitro permeability across the intact skin (83.6 ${\pm}$ 5.42${\mu}$l/$\textrm{cm}^2$/h ). However, due to the limited solubility of DA-5018 in IPM (0.53 mg/ml), the maximal flux from the IPM medium remained at only 44.3 ${\pm}2.87{\mu}$g/$\textrm{cm}^2$/hr. In order to increase the flux, addition of better solvents for DA-5018 was attempted, under the assumption that flux is the result of both solubility and permeability. Ethoxydiglycol (EG) and oleic acid (OA) were selected as examples of food solvents. The addition of IC or OA to IPM at a 1:1 volume ratio resulted in a comparable increase in the solubility of the compound (i.e., to 61.1 and 50.2 mg/ml for EG and OA, respectively). However, the addition of EG at a 1:1 volume ratio, for example, increased the flux 6.3 fold (i.e., $279{\mu}$g/$\textrm{cm}^2$/hr), while OA, at a 1:1 volume ratio, decreased the flux 5 fold (i.e., $9.26{\mu}$g/$\textrm{cm}^2$//hr). The mechanism of this discrepancy between EG and OA was investigated by measuring the permeabilty of DA-5018 across the stratum corneum-removed skin of the mouse, under the hypothesis that the viable skin layer may serve as a barrier for the permeation of lipophilic substances such as DA 5018. The permeability of DA-5018, from the medium of EG or OA, across the viable skin differed greatly for EG ($0.41{\mu}$l/$\textrm{cm}^2$/hr) and OA ($0.086{\mu}$l/$\textrm{cm}^2$/hr), suggesting that a higher permeability across the viable skin layer is needed for the second solvents. The maximum flux across the intact skin was achieved for DA-5018 when EG was added to IPM at a 1:1 volume ratio. Thus, the use of a binary system appears to be the best approach for realizing the transdermal delivery of DA-5018 at a reasonable rate.

  • PDF

$MgB_2$ 결정립 나노브릿지 특성에 관한 연구 (Properties of $MgB_2$ Intragrain Nanobridges)

  • 홍성학;이순걸;성원경;강원남;김동호;김영국;정국채
    • Progress in Superconductivity
    • /
    • 제10권2호
    • /
    • pp.74-78
    • /
    • 2009
  • Inter-grain nanobridges of the $MgB_2$ superconductor have been fabricated by focused-ion-beam(FIB) and their electrical transport properties were studied. The $MgB_2$ film was prepatterned into microbridges by a standard argon ion milling technique and then FIB-patterned into 100 nm$\times$100 nm bridges. Current-voltage characteristics showed a strong flux-flow type behavior at all temperatures with a trait of Josephson coupling near $T_c$. At low temperatures, the curves showed a two-step resistance-doubled transition with occasional hysteresis. The resistance-doubling transition is believed to be due to a two-channel flux-flow effect. The temperature-dependent critical current data showed $I_c(T){\propto}(1-T/T_c)^2$ near $T_c$, same as a normal barrier junction, and $I_c(T){\propto}(1-T/T_c)^{1.2}$ at low temperatures, similar to that of a film.

  • PDF

Effect of Lateral Diffusion on Hydrogen Permeation Measurement in Thick Steel Specimens

  • Traidia, A.;El-Sherik, A.M.;Attar, H.;Enezi, A.
    • Corrosion Science and Technology
    • /
    • 제16권4호
    • /
    • pp.201-208
    • /
    • 2017
  • A finite element analysis is proposed to study the effect of specimen dimensions on lateral diffusion of hydrogen during hydrogen permeation flux measurements. The error of measurement on thick specimens because of 1D diffusion approximation may be as much as 70%. A critical condition for accurate measurements is to designate the area of hydrogen monitoring/exit surface smaller than the area of hydrogen charging/entry surface. For thin to medium thickness specimens (ratio of thickness to specimen radius of 5:10 and below), the charging surface should be maximized and the monitoring surface should be minimized. In case of relatively thick specimens (ratio of thickness to specimen radius above of 5:10), use of a hydrogen-diffusion barrier on the specimen boundaries is recommended. It would completely eliminate lateral losses of hydrogen, but cannot eliminate the deviation towards 2D diffusion near the side edges. In such a case, the charging surface should be maximized and the monitoring surface should be as closer in dimension as the charging surface. A regression analysis was carried out and an analytical relationship between the maximum measurement error and the specimen dimensions is proposed.

Water Balance Evaluation of Final Closure Cover for Near- surface Radioactive Wastes Disposal Facility

  • Keunmoo Chang;Park, Joo-Wan;Yoon, Jeong-Hyoun;Park, Heui-Joo;Kim, Chang-Lak
    • Nuclear Engineering and Technology
    • /
    • 제32권3호
    • /
    • pp.274-282
    • /
    • 2000
  • The simulation of water balance was conducted for suggested four alternative multi-layer cover design of near-surface radioactive waste disposal facility under domestic climate condition. The analysis was also conducted for the most favorable one out of four alternative cover design under conservative scenarios. Until 100 years after closure of disposal vault, the infiltration flux for the most favorable cover design was negligible even under doubling of the ambient precipitation condition. When the degradation of asphalt and geomembrane after 100 years of closure was considered, the infiltration flux significantly increased almost to the design criteria of cover system in I' Aube disposal facility. And it was found that the hydraulic conductivity of bentonite/sand as a bottom barrier should be no greater than 1$\times$10$^{-7}$ cm/sec recommended by U.S. EPA.

  • PDF

풀비등에서 소형 사각기둥핀 배열형상에 따른 FC-72의 응축특성 (Condensing Characteristics of Pin-finned Surfaces on Pool Boiling in FC-72)

  • 강상우;김서영
    • 설비공학논문집
    • /
    • 제23권7호
    • /
    • pp.498-504
    • /
    • 2011
  • As the electronic industry rapidly develops, the heat flux from state-of-the-art electronics increases up to $10^6\;W/m^2$. For this reason, the development of a new cooling technology for high heat flux applications is strongly required. Recently, some cooling technologies using boiling and condensation of working fluid are being adopted to overcome such a technical barrier. In the present study, a smooth boiling surface ($14{\times}14\;mm^2$) was immersed in FC-72 and its vapor was condensed by four different types of condensation surfaces ($30{\times}30\;mm^2$ base). The condensing surfaces were composed of a smooth surface and $1{\times}1\;mm^2$ pin-finned surfaces of 2 mm height with 0.3, 0.5 and 1 mm array spacing. Boiling and condensing characteristics were investigated in detail on their combinations of boiling and condensing surfaces. For a smooth boiling surface the results obtained showed that the pin-finned condensing surface with 1 mm array spacing yielded the best performance and the smooth condensation surface did the worst. Furthermore hysteresis phenomena could be reduced by using enhanced condensing surfaces.