• Title/Summary/Keyword: Flux treatment

Search Result 745, Processing Time 0.026 seconds

Development of Mass Transfer Models for Ammonia Flux Estimation from Sewage Treatment Plants (하수처리장에서의 암모니아 플럭스 산정을 위한 물질전달모형 개발)

  • Sa, Jae-Hwan;Jeon, Eui-Chan;Jeong, Jae-Hak
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.5
    • /
    • pp.701-711
    • /
    • 2006
  • Sewage treatment plants located near to large cities emit extremely higher concentration of odorous materials. This study evaluated flux profiles of ammonia emitted from the water surface of sewage treatment plants using a dynamic flux chamber. Also, an ammonia overall mass transfer coefficient and a mass transfer model was developed in order to estimate fluxes of ammonia using environment parameters and the flux from the sewage treatment plants. The developed mass transfer model was evaluated through a fitness analysis. Comparison modeled flux applying empirical overall mass transfer coefficients of ammonia and measured ammonia flux show a high linearity with 0.977. The flux ratio of 1.282 demonstrated highly statistical fitness, also. Modeled flux using the mass transfer model was compared with measured flux. In result, it indicated that empirical overall mass transfer coefficients were similar to measured flux. The mass transfer model using the empirical overall mass transfer coefficient developed in this study was proved to be an easy and effective method to make accurate and precise predictions for ammonia flux discharged from sewage treatment plants.

Effects of Flux Treatment on the Glass Forming Ability and Magnetic Properties of Fe-based Ternary Amorphous Alloys

  • Zuo, Mingqing;Yi, Seonghoon
    • Journal of Korea Foundry Society
    • /
    • v.40 no.4
    • /
    • pp.113-117
    • /
    • 2020
  • A series of Fe-P-B and Fe-Si-B amorphous alloys with high Fe contents exceeding 90 wt.% was successfully prepared by combining flux treatment and melt-spinning technique. The effects of Fe content and the flux treatment on the thermal and magnetic properties of amorphous alloys were studied. The glass-forming ability and the thermal stability of amorphous ribbons can be improved by a flux treatment, revealing the effective removal of heterogeneous nucleation sites in the ribbons through the flux treatment. It was found that Fe-Si-B ribbons exhibit higher saturation magnetization levels than Fe-P-B ribbons.

A Study on the Opimization of Process and Operation Condition for Membrane System in Tap Water Treatment (분리막을 이용한 정수처리 System에서 처리공정 및 운전조건의 최적화에 관한연구)

  • 오중교
    • Membrane Journal
    • /
    • v.9 no.4
    • /
    • pp.193-201
    • /
    • 1999
  • The object of study were the development of membrane process and the optimization of operation condition for membrane system, which was used the pre-treatment system of tap water treatment in steady of conventional process such as coagulation, sedimentation. The higher steady flux is very important factor, by a suitable pre-treatment and optimization of operating condition such as fouling control, crossflow and backwashing method, in membrane system. So, we were observed the effect of flux decline for membrane used by 4 type ultrafiltration(UF) membrane pre-treatment process, and optimized the operation condition of filtration system under various MWCO(Molecular weight cut-off), operation pressure, linear velocity and temperature to maintain higher flux. From these experiment, we were identified that UF process showed a slower flux decline rate and a higher flux recovery than microfiltration(MF) membrane. The water quality of UF permeate was better than that of MF, and was not effected pre-treatment process. In the operation condition, the rate of flux decline was diminished by a higher linear velocity and operation temperature, lower pressure.

  • PDF

Hydrophilic Modification of Polypropylene Hollow Fiber Membrane by Dip Coating, UV Irradiation and Plasma Treatment

  • Kim Hyun-Il;Kim Jin Ho;Kim Sung Soo
    • Korean Membrane Journal
    • /
    • v.7 no.1
    • /
    • pp.19-27
    • /
    • 2005
  • PP hollow fiber membrane was hydrophilized by EVOH dip coating followed by low temperature plasma treatment and UV irradiation. EVOH coating attained high water flux without any prewetting but its stability did not guaranteed at high water permeation rate. At high water permeation rate, water flux declined gradually due to swelling and delamination of the EVOH coating layer causing pore blocking effect. However, plasma treatment reduces the swelling, which suppress delamination of the EVOH coating layer from PP support result in relieving the flux decline. Also, UV irradiation helped the crosslinking of the EVOH coating layer to enhance the performance at low water permeation rate. FT-IR and ESCA analyses reveal that EVOH dip coating performed homogeneously through not only membrane surface but also matrix. Thermogram of EVOH film modified plasma treatment and W irradiation show that crosslinking density of EVOH layer increased. Chemical modification by plasma treatment and UV irradiation stabilized the hydrophilic coating layer to increase the critical flux of the submerged membrane.

Development of High-Temperature Heat Flux Gauge for Steel Quenching (강재 급속냉각용 고온 열유속게이지 개발)

  • Lee, Jungho
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.23 no.6
    • /
    • pp.323-330
    • /
    • 2010
  • The present study was motivated by increasing demands on quantitative measurements of the heat flux through the water cooling and quenching process of hot steel. The local heat flux measurements are employed by a novel experimental technique that has a function of high-temperature heat flux gauge in which test block assemblies are directly used to measure the heat flux variation during water cooling and quenching of hot steel. The heat flux can be directly achieved by Fourier's law and is also compared with numerical estimation which is solved by inverse heat conduction problem (IHCP). The high-temperature heat flux gauge developed in this study can be applicable to measure cooling rate and history during the actual cooling applications of steelmaking process. In addition, the measurement uncertainty of heat flux is calculated by a quantitative uncertainty analysis which is based on the ANSI/ASME PTC 19.1-2005 standard.

Dyestuff Wastewater Treatment by Membrane Separation as Post-treatment after lenten막s Reaction (펜턴반응후 후처리로써 막분리에 의한 염색폐수처리)

  • 김선일;윤영재
    • Journal of Environmental Science International
    • /
    • v.7 no.1
    • /
    • pp.74-80
    • /
    • 1998
  • Because permeate flux was very low as It has the suspension soled of higher concentration In the trafiltration membrane separation treatment of dyestuff wastewater, pre-treatment of Ponton reaction was carried out. In the case of pH 3, COD removal rate was the hi각erst of 58%. When PAC was added into the pre-treatment supernatant, the COD removal rate was found to be 53% , and when COD was 153mg/L, the removal rate was 92.3% in the trafiltration separation. In addition, the effect of the addition of PAC on the permeate flux was also investigated. The decrease of permeate flux In the presence of PAC was higher than In the abscence of PAC, but the recovery of permeability by cleaning was better In the case of PAC system.

  • PDF

Effect of Post Heat Treatment on Wear Characteristics of Thermally Sprayed Co-based Self-flux Alloy Coating (코발트기 자융성합금 코팅의 마모특성에 미치는 후열처리의 영향)

  • Lee, Jae-Hong;Kim, Yeong-Sik
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.106-111
    • /
    • 2014
  • This article describes effect of post heat treatment on wear characteristics of thermally sprayed Co-based self-flux alloy coating. Co-based self-flux alloy coatings were deposited on steel substrates using a flame spray process. Post heat treatments were carried out at 800, 900, 1000 and $1100^{\circ}C$ for 30min in a vacuum chamber. For analysis of effect of post heat treatment on mechanical properties, wear test and hardness test were performed for post heat-treated coating specimen. Microstructures of heat treated coating layer and wear track were examined using SEM and EDS. Wear loss and hardness became lower with increasing post heat treatment temperature.

Development of NH3 Emission Factors using a Dynamic Flux Chamber in a Sewage Treatment Plant (부유형 챔버를 이용한 하수처리장에서의 암모니아 배출 특성 연구)

  • Jeon, Eui-Chan;Sa, Jae-Hwan;Park, Jong-Ho
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.5
    • /
    • pp.263-273
    • /
    • 2005
  • In this study, the major emission procedures and emission characteristics were identified at the site of sewage treatment plant which is one of the major sources of ammonia. At the same time the emission factors and emission rates were estimated. In order to calculate the emission flux, we used a Dynamic Flux Chamber(DFC), which is found to be a proper sampling devise for area sources such as sewage treatment plant. It was found that the most stable sampling condition was when the stirrer's speed of DFC was 120RPM, and it would be the best time to take a sample 60 minutes later after setting the chamber. The relatively higher flux was shown in Autumn compared to summer and winter. Annual ammonia emission rates procedures were calculated as $906.32{\mu}g/activity-ton$, $1,114.72{\mu}g/activity-ton$ and $437.53{\mu}g/activity-ton$ each at the primary settling basin, aeration basin and the final settling basin, respectively. The ammonia emission rate the highest at in the aeration basin according to this test. This results was due to that the surface of aeration basin or the final settling basin is relatively wider than the primary settling basin.

Effect of Heat Treatment Conditions on the Microstructure and Wear Behavior of Ni-based Self-flux Alloy Coatings (니켈기 자융성 합금 코팅층의 미세구조 및 마모거동에 미치는 후열처리 조건의 영향)

  • Kim, K.T.;Oh, M.S.;Kim, Y.S.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.121-126
    • /
    • 2007
  • This study aims at investigating the effect of heat treatment conditions on the dry sliding wear behavior of thermally sprayed Ni-based self-flux alloy coatings. Ni-based self-flux alloy powders were sprayed onto a carbon steel substrate and then heat-treated at 700, 800, 900 and $1000^{\circ}C$ for 30 minutes in a vacuum furnace. Dry sliding wear tests were performed using sliding speed of 0.4 m/s and applied load of 6 N. AISI 52100 ball(diameter 8 mm) was used as counterparts. Microstructure and wear behavior of both as-sprayed and heat-treated Ni-based self-flux alloy coatings were studied using a scanning electron microscope(SEM), energy dispersive X-ray spectroscopy(EDX), electron probe micro-analysis(EPMA) and X-ray diffraction(XRD). It was revealed that microstructure and wear behavior of thermally sprayed Ni-based self-flux alloy coatings were much influenced by heat treatment conditions.

  • PDF