• Title/Summary/Keyword: Flux pump

Search Result 139, Processing Time 0.036 seconds

A Study on the Design and Analysis of the Fuel Boost Pump Motor Assembly for an Aircraft (항공기용 연료승압펌프 모터 조립체 설계에 대한 연구)

  • Lee, Jung-hoon;Kim, Joon-tae
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.3
    • /
    • pp.1-8
    • /
    • 2018
  • The fuel pump, which is used for an aircraft, was first developed in Korea through the Civil-Military Dual Components Development Program. The BLDC motor type, which is superior to the DC brush motor when considering efficiency, endurance, and explosive environmental characteristics, was applied to the fuel pump given its capacity and operating condition. The magnetic flux of the permanent magnet was analyzed based on the magnet flux density equation, using the Maxwell equation and the environmental condition. The motor performance, according to the load, was analyzed using the finite element method in order to design validation. The motor assembly was developed by designing the motor drive and the EMI filters. The performance test results of the motor assembly for the fuel boost pump were consistent with the analysis.

Development of Energy Storage System Combined with Solar System and Superconducting Magnet (초전도 마그넷을 이용한 태양광에너지 저장장치 개발)

  • Kim, Dae-Wook;Chung, Yoon-Do;Yoon, Yong-Soo;Kim, Tae-Jung;Kim, Hyun-Ki;Ko, Kae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.888-889
    • /
    • 2011
  • As new one of superconducting power supplies, we proposed an HTS flux pump utilized a solar energy system. As an eternal electric energy can be converted by the solar system, the solar energy system is promisingly applied as an energy source in the power applications. A solar energy system is comprised of solar panel, photo-voltaic (PV) controller, converter and battery. The HTS flux pump consists of an electromagnet, two thermal heaters and a Bi-2223 magnet. In this paper, we describe the possibility the fusion technology between superconducting power supply and solar energy system. As a fundamental step, the fabrication, structure and experimental results are explained.

  • PDF

Design and Analysis of Voice Coil Actuator to Drive Fuel Pump in Automobile (자동차 연료펌프 구동용 보이스 코일 전자기 엑츄에이터의 설계 및 해석)

  • Park, Se-Myung;Kim, Jin-Ho;Bai, Cheol-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.6
    • /
    • pp.234-238
    • /
    • 2010
  • Solenoid diaphragm fuel pump, which to replace mechanical fuel pump system by utilizing cam-shaft driving force, is in the spotlight for being a high efficient green car component. However, there is a drawback in power consumption as a solenoid diaphragm fuel pump only relies on solenoid for its flux needed in reciprocating motion. Therefore, this research proposes permanent magnet type VCM (Voice Coil Motor) fuel pump system to minimized power consumption. Furthermore, the study compares and analyzes power consumption and dynamic performance between the current and the former solenoid diaphragm pump by conducting finite element analysis with the commercial electromagnetic solver, MAXWELL.

Study on the Evaporation Heat transfer of $CO_2$ in a Horizontal tube (수평관내의 $CO_2$의 증발 열전달에 관한 연구)

  • Jang, Seong-Il;Choi, Sun-Muk;Kim, Dae-Hui;Oh, Hoo-kyu
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.240-241
    • /
    • 2005
  • The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section was made of a horizontal stainless steel tube with the inner diameter of 4.57 mm, and length of 4 m. The experiments were conducted at mass flux of 200 to 700 kg/$m^2s$, saturation temperature of 0$^{circ}C$ to 20$^{circ}C$, and heat flux of 10 to 30 kW/$m^2$. The test results showed the evaporation heat transfer of $CO_2$ has great effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. In comparison with test results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient of $CO_2$, therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

  • PDF

Evaporation Pressure Drop of Carbon Dioxide in a Horizontal Tube (수평관내 이산화탄소의 증발 압력강하)

  • Ku, H.K.;Son, C.H.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.63-69
    • /
    • 2007
  • The evaporation pressure drop of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and an evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of 4.57 mm inner diameter. The experiments were conducted at saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed that the evaporation pressure drop of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. The measured pressure drop during the evaporation process of $CO_2$ increases with increased mass flux, and decreased saturation temperature. The evaporation pressure drop of $CO_2$ is much lower than that of R 22. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the previous correlation. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.

  • PDF

Flow Analysis, Experiment and Investigation of Electromagnetic Pump (전자기 펌프의 특성해석, 실험 및 고찰)

  • Jeon, Mun-Ho;Kim, Jung-Hyun;Kim, Min-Seok;Kim, Chang-Eob
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.74-76
    • /
    • 2006
  • This paper presents the experiment and characteristics analysis of electromagnetic pump using linear induction motor(LIM). The electromagnetic pump is used to transfer the molten metals by electromagnetic force of LIM. The characteristics of LIM pump for molten metals: zinc, tin, aluminum are analysed solving the magnetohydrodynamics at constant magnetic flux. The molten zinc is used in the experiment and the experimental results are compared with the analysis.

  • PDF

An Accelerated Life Test of Booster Pump for Water Purifier (정수기용 부스터펌프의 가속수명시험)

  • Moon, Ji-Seob;Jeong, Seon-Yong;Kim, Myung-Soo
    • Journal of Applied Reliability
    • /
    • v.11 no.3
    • /
    • pp.281-291
    • /
    • 2011
  • This paper presents an accelerated life test of booster pump for home water purifier. The failure analysis shows that decreased flux due to the plastic deformation of bypass spring adjusting pressure is the predominant failure mechanism. An accelerated life test is designed and implemented to estimate the lifetime of the booster pump. Temperature, water pressure and voltage are selected as accelerating variables through the technical review about failure mechanism. It is assumed that the lifetimes of booster pumps follow lognormal distribution and the combination model of temperature and non-thermal stresses holds. The life-stress relationship, acceleration factor, and $B_{10}$ life at design condition are estimated by analyzing the accelerated life test data.

The Condensation Heat Transfer of Alternative Refrigerants for R-22 in Small Diameter Tubes (세관내 R-22 대체냉매의 응축열전달에 관한 연구)

  • Son, Chang-Hyo;Jeong, Jin-Ho;O, Jong-Taek;O, Hu-Gyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.2
    • /
    • pp.180-186
    • /
    • 2001
  • The condensation heat transfer coefficients of pure refrigerants R-22, R-134a, and a binary refrigerant mixture R-410A flowing in a small diameter tube were investigated. The experiment apparatus consists of a refrigerant loop and a water loop. The main components of the refrigerant loop consist of a variable-speed pump, a mass flowmeter, an evaporator, and a condenser(test section). The water loop consists of a variable-speed pump, an isothermal tank, and a flowmeter. The condenser is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. The test section consists of smooth, horizontal copper tube of 3.38mm outer diameter and 1.77mm inner diameter. The length of test section is 1220mm. The refrigerant mass fluxes varied from 450 to 1050kg/(㎡$.$s) and the average inlet and outlet qualities were 0.05 and 0.95, respectively. The main results were summarized as follows ; in the case of single-phase flow, the heat transfer coefficients increase with increasing mass flux. The heat transfer coefficient of R-410A was higher than that of R-22 and R-134a, and the heat transfer for small diameter tubes were about 20% to 27% higher than those predicted by Gnielinski. In the case of two-phase flow, the heat transfer coefficients also increase with increasing mass flux and quality. The condensation heat transfer coefficient of R-410A was slightly higher than that of R-22 and R-134a. Most of correlations proposed in the large diameter tube showed significant deviations with experimental data except for the ranges of low quality and low mass flux.

Evaporation Pressure Drop of Carbon Dioxide in Horizontal Tubes with Inner Diameter of 4.57 mm and 7.75 mm (내경 4.57과 7.75 mm인 수평관내 이산화탄소의 증발 압력강하)

  • Son, Chang-Hyo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.3
    • /
    • pp.30-37
    • /
    • 2008
  • The evaporation pressure drop of $CO_2$ (R-744) in horizontal tubes was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of 7.75 and 4.57 mm inner diameter. The experiments were conducted at saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed the evaporation pressure drop of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. The pressure drop measured during the evaporation process of $CO_2$ increases with increased mass flux, and decreases as the saturation temperature increased. The evaporation pressure drop of $CO_2$ is very lower than that of R-22. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the correlation of Choi et al. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.

The Estimating an Effect of Rapid Flux Increase to a Membrane in the Intermittent Aeration MBR Process Using Alum Treatment (응집제를 활용한 간헐포기 MBR공정에서 순간플럭스 증가가 분리막에 미치는 영향 평가)

  • Choi Song-Hyu;Cho Nam-un;Han Myong Su
    • Membrane Journal
    • /
    • v.15 no.1
    • /
    • pp.70-83
    • /
    • 2005
  • By supplying air intermittently in various mode, the effects of oxic/anoxic time ratio and air scrubbing in aeration condition on the membrane flux and permeability were investigated. When suction pump stops, vacuum pressure remains inside the suction pump. Therefore, the effect of remaining vacuum pressure in the suction pump on fouling of membrane was investigated. The effect of EPS (Extra cellular Polymeric Substance) which is generated due to the long SRT and high concentration of MLSS and the dose of coagulant on the membrane were also investigated. The suitable oxic/anoxic time ratio for the best removal efficiency of organic matter and nitrogenous matter was 40 minutes (Oxic) : 20 minutes (Anoxic). At this time ratio, alum was dosed into the aeration tank. The result of dosing alum was that the concentration of alum solution might affect nitrification and denitrification. To remove 1 mg/L of phosphorus in MBR process, it needs 0.75 mg/L of alum solution.