• Title/Summary/Keyword: Flux function

Search Result 533, Processing Time 0.024 seconds

Design of a CT Saturation Detection Technique with the Countermeasure for a Spike Signal

  • Kang, Yong-Cheol;Yun, Jae-Sung
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.2
    • /
    • pp.85-92
    • /
    • 2003
  • When a current transformer (CT) is saturated, the wave-shape of the secondary current is distorted and contains points of inflection, which correspond to the start or end of each saturation period. Discontinuity in the first-difference function of the current arises at points of inflection, where the second and third differences convert into pulses that can be used to detect saturation. This paper describes the design and evaluation of a CT saturation detection technique using the third-difference function and includes the countermeasure for a spike signal. Test results clearly demonstrate that the algorithm successfully detects the start and end of each saturation period irrespective of the remanent flux and magnetization inductance in the saturated region. This paper concludes by describing the results of hardware implementation of the algorithm using a DSP.

A Far Field Solution of the Slowly Varying Drift Force on an Offshore Structure in Bichromatic Waves - Two Dimensional Problems

  • Lee, Sang-Moon
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.2
    • /
    • pp.7-12
    • /
    • 2008
  • A far field solution of the slowly varying force on an offshore structure by gravity ocean waves was shown as a function of the reflection and transmission of the body disturbed waves. The solution was obtained from the conservation of the momentum flux, which simply describes various wave forces, while making it unnecessary to compute complicated integration over a control surface. The solution was based on the assumption that the frequency difference of the bichromatic incident waves is small and its second order term is negligible. The final solution is expressed in term of the reflection and transmission waves, i.e. their amplitudes and phase angles. Consequently, it shows that not only the amplitudes but also the phase differences make critical contributions to the slowly varying force. In a limiting case, the slowly varying force solution gives the one of the mean drift force, which is only dependent on the reflection wave amplitude. An approximation is also suggested in a case where only the mean drift force information is available.

A NEW FUNCTION SPACE Lα(X) VERSION 1.1

  • Pak, Hee Chul;Chang, Sang-Hoon
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.21 no.4
    • /
    • pp.471-481
    • /
    • 2008
  • We develop a new function space $L_{\alpha}(X)$ that generalizes the classical Lebesgue space $L^p(X)$. The generalization is focused on a better explanation of the flux terms arising from many dynamics.

  • PDF

Phospholipid Polymer, 2-Methacryloyloxyethyl Phosphorylcholine and Its Skin Barrier Function

  • LeeCho, Ae-Ri
    • Archives of Pharmacal Research
    • /
    • v.27 no.11
    • /
    • pp.1177-1182
    • /
    • 2004
  • The effect of poly[2-methacryloyloxyethyl phosphorylcholine] (pMPC) on the skin permeation property was investigated by performing in vitro skin permeation study of a model drug, nicotinic acid (NA). Effect of pMPC polymer in donor solution on skin permeation rates was evaluated using side-by-side diffusion cells. Also, the structural alterations in the stratum corneum (SC), inter-lamellar bilayer (ILB) and dermis layers in pMPC-treated and -untreated skin sections were investigated with transmission electron microscopy (TEM). The permeation profile of NA without pMPC in donor solution showed biphasic mode: initial $1^{st} phase and 2^{nd}$ hydration phase. The sudden, more than 10-fold increase in flux from the initial steady state (43.5 $\mu g/cm^2$/hr) to the $2^{nd}$ hydration phase (457.3 $\mu g/cm^2$/hr) suggests the disruption of skin barrier function due to extensive hydration. The permeation profile of NA with 3% pMPC in the donor solution showed monophasic pattern: the steady state flux (10.9 $\mu g/cm^2$/hr) without abrupt increase of the flux. The degree of NA permeation rate decreased in a concentration-dependent manner of pMPC. TEM of skin equilibrated with water or 2% pMPC for 12 h showed that corneocytes are still cohesive and epidermis is tightly bound to dermis in 2% pMPC-treated skin, while wider separation between corneocytes and focal dilations in inter-cellular spaces were observed in water-treated skin. This result suggests that pMPC could protect the barrier property of the stratum corneum by preventing the disruption of ILB structure caused by extensive skin hydration during skin permeation study.

Annealing Effects of Amorphous Cores for the Application of Flux-gate Sensors (Flux-gate 센서용 비정질 코아의 열처리효과)

  • 김용준;손대락;손동환
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.3
    • /
    • pp.134-140
    • /
    • 2001
  • Flux-gate magnetometer was developed in 1930's, and it has been widely used for the low magnetic field measurements. In this work, we have employed amorphous ribbon 2714A produced by Allied Chem. Co. as sensor core material. To develop low noise, low power consumption, and high reliability flux-gate magnetometer, we have measured ac magnetic properties depending on the annealing conditions. As quenched state amorphous core shows high noise level and ac magnetic properties were changed under the condition of accelerated aging test, but amorphous ribbon, which was annealed under 350 $\^{C}$ during 1 hour, shows low noise level of 0.1 nT in the frequency range of dc∼10 Hz which was 10 times better than the as quenched amorphous ribbon. Under accelerated aging test, ac magnetic properties such as squareness and coercivity of the annealed samples show higher reliability and approached to a certain limiting value as exponential function. We can see that high reliability and low noise flux-gate magnetometer could be developed, if we consider this ac magnetic properties change in the sensor design.

  • PDF

Sensitivity Analysis (Q10) of Carbon Dioxide Flux with Soil Temperature in the Grassplot (잔디밭에서 지온에 대한 이산화탄소 플럭스의 민감도(Q10) 분석)

  • Kang, Dong-hwan;So, Yoon Hwan;Kwon, Byung Hyuk;Kim, Park Sa
    • Journal of Environmental Science International
    • /
    • v.28 no.9
    • /
    • pp.785-795
    • /
    • 2019
  • In order to analyze the sensitivity of carbon dioxide flux by soil temperature in the grassplot, carbon dioxide flux and soil temperature were observed 24 times from March, 2010 to March, 2011 at nine sites in the grassplot. The average of $CO_2$ in the grassplot is $2.2{\sim}36.7^{\circ}C$, the highest in August, the lowest in January, and the average of carbon dioxide flux is $12{\sim}1479mgCO_2{\cdot}m^{-2}{\cdot}hr^{-1}$, and the carbon dioxide emission from the grassplot to the atmosphere was 10 times higher in summer than in winter. The temperature response coefficient estimated by the exponential function of carbon dioxide flux according to soil temperature was ranged from 0.1065 to 0.1274, and the increase tendency of $CO_2$ flux with soil temperature was linear at $0{\sim}20^{\circ}C$ and exponential at $20{\sim}40^{\circ}C$. The $Q_{10}$ values for each of nine observation sites on the grassplot was in the range of 2.901 ~ 3.575, and the $Q_{10}$ value using the total data observed in the lawn was estimated to be 3.374. In the homogeneous grassplot area, the average of $Q_{10}$ values by observation point and the $Q_{10}$ value by the total data were estimated similarly.

Prediction of Radiative Heat Transfer in a Three-Dimensional Gas Turbine Combustor with the Finite-Volume Method (유한체적법에 의한 복잡한 형상을 갖는 3차원 가스터빈 연속기내의 복사열 전달 해석)

  • Kim, Man-Yeong;Baek, Seung-Uk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.8
    • /
    • pp.2681-2692
    • /
    • 1996
  • The finite-volume method for radiation in a three-dimensional non-orthogonal gas turbine combustion chamber with absorbing, emitting and anisotropically scattering medium is presented. The governing radiative transfer equation and its discretization equation using the step scheme are examined, while geometric relations which transform the Cartesian coordinate to a general body-fitted coordinate are provided to close the finite-volume formulation. The scattering phase function is modeled by a Legendre polynomial series. After a benchmark solution for three-dimensional rectangular combustor is obtained to validate the present formulation, a problem in three-dimensional non-orthogonal gas turbine combustor is investigated by changing such parameters as scattering albedo, scattering phase function and optical thickness. Heat flux in case of isotropic scattering is the same as that of non-scattering with specified heat generation in the medium. Forward scattering is found to produce higher radiative heat flux at hot and cold wall than backward scattering and optical thickness is also shown to play an important role in the problem. Results show that finite-volume method for radiation works well in orthogonal and non-orthogonal systems.

3D simulation of Heat transfer in MEMS-based microchannel (MEMS 로 제작된 마이크로 채널에서의 3 차원 열전달 해석)

  • Choi, Chi-Woong;Huh, Cheol;Kim, Dong-Eok;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1870-1875
    • /
    • 2007
  • The microchannel heat sink is promising heat dissipation method for high heat flux source. Contrary to conventional circular channel, MEMS based microchannel had rectangular or trapezoidal cross-sectional shape. In our study, we conducted three dimensional conjugate heat transfer calculation for rectangular shape microchannel. First, we simulated that channel was completely drained with known heating power. As a result we obtained calibration line, which indicates heat loss was function of temperature. Second, we simulated single phase heat transfer with various mass flux, 100-400 $kg/m^2s$. In conclusion, the single phase test verified that the present heat loss evaluation method is applicable to micro scale heat transfer devices. Heat fluxes from each side wall shows difference due to non-uniform heating. However those ratios were correlated with supplied total heat. Finally, we proposed effective area correction factor to evaluate appropriate heat flux.

  • PDF

Application of Box Wilson experimental design method for removal of acid red 95 using ultrafiltration membrane

  • Akdemir, Ezgi Oktav
    • Membrane and Water Treatment
    • /
    • v.9 no.5
    • /
    • pp.309-315
    • /
    • 2018
  • The applicability of the ultrafiltration process for color removal from dye-containing water has been examined in this study. The optimization of major process variables, such as dye concentration, chitosan concentration and transmembrane pressure on permeate flux and color removal efficiency was investigated. To find the most appropriate results for the experiment, the Box-Wilson experimental design method was employed. The results were correlated by a response function and the coefficients were determined by regression analysis. Permeate flux variation and color removal efficiency determined from the response functions were in good agreement with the experimental results. The optimum conditions of chitosan concentration, dye concentration and pressure were 50 mg/l, 50 mg/l and 3 bars, respectively for the highest permeate flux. On the other hand, optimum conditions for color removal efficiency were determined as 50 mg/l of dye concentration, 50 mg/l of chitosan concentration and 1 bar of pressure.