• Title/Summary/Keyword: Flux function

Search Result 533, Processing Time 0.029 seconds

A Busbar Current Differential Relay with a Compensating Algorithm (보상 알고리즘을 적용한 모선보호용 전류차동 계전기)

  • 강용철;윤재성
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.4
    • /
    • pp.214-214
    • /
    • 2004
  • This paper describes a busbar current differential relay in conjunction with a current transformer(CT) compensating algorithm irrespective of the level of the remanent flux. The compensating algorithm detects the start of first saturation if the third-difference function of the current exceeds the threshold; it estimates the core flux at the first saturation start by inserting the negative value of the third-difference function of the current into the magnetization curve; thereafter, it calculates the core flux during the fault and compensates the distorted current using the magnetization curve. The algorithm estimates the correct secondary current irrespective of the level of the remanent flux and needs no saturation point of the magnetization curve. The proposed relay can improve not only security of the relay on an external fault with CT saturation but sensitivity of the relay on an internal fault; the relay can improve the operating speed on n internal fault with CT saturation. This paper concludes by implementing the relay into a digital signal processor based prototype relay.

Comparison of Rotor Flux Observer Characteristics in Induction Motor Using Parameter Sensitivity (파라미터 민감도를 이용한 유도전동기 회전자 자속관측기의 특성 비교)

  • 최종우;남현택;박용환;김흥근
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.377-383
    • /
    • 2002
  • To obtain a high performance in a direct vector controlled induction machine, it is essential to obtain the current rotor flux. The accuracy of flux observers for induction machines inherently depends on parameter sensitivity. This paper proposes an analysis method for conventional flux observers using "parameter sensitivity". The "parameter sensitivity" is defined as the ratio of the percentage change in the system transfer function to the percentage change of the parameter variation. We define the ratio between real flux and estimated no as the transfer function, and analyze a parameter sensitivity of this transfer function. Practical verification is presented to conform the capabilities of the proposed analysis method.sed analysis method.

COMPARATIVE STUDY ON FLUX FUNCTIONS AND LIMITERS FOR THE EULER EQUATIONS (Euler 방정식의 유량함수(Flux Function)와 제한자(Limiter) 특성 비교 연구)

  • Chae, E.J.;Lee, S.
    • Journal of computational fluids engineering
    • /
    • v.12 no.1
    • /
    • pp.43-52
    • /
    • 2007
  • A comparative study on flux functions for the 2-dimensional Euler equations has been conducted. Explicit 4-stage Runge-Kutta method is used to integrate the equations. Flux functions used in the study are Steger-Warming's, van Leer's, Godunov's, Osher's(physical order and natural order), Roe's, HLLE, AUSM, AUSM+, AUSMPW+ and M-AUSMPW+. The performance of MUSCL limiters and MLP limiters in conjunction with flux functions are compared extensively for steady and unsteady problems.

STUDY ON FLUX FUNCTIONS FOR THE EULER EQUATIONS (Euler 방정식의 Flux Function 특성 비교 연구)

  • Chae, E.J.;Lee, S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.36-40
    • /
    • 2006
  • A comparative study on flux functions for the 2-dimensional Euler equations has been conducted. Explicit 4-stage Runge-Kutta method is used to integrate the equations. Flux functions used in the study are Steger-Warming's, van Leer's. Godunov's, Osher's(physical order and natural order), Roe's, HILE, AUSM, AUSM+ and AUSMPW+. The performance of MUSCL limiters and MLP limiters in conjunction with flux functions are compared extensively for steady and unsteady problems.

  • PDF

An Advanced Algorithm for Compensating the Secondary Current of CTs (개선된 변류기 2차 전류 보상 알고리즘)

  • 강용철;임의재
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.7
    • /
    • pp.387-392
    • /
    • 2003
  • During a fault the remanent flux in a current transformer (CT) may cause severe saturation of its core. The resulting distortion in the secondary current could cause the mal-operation of a protection relay. This paper proposes an algorithm for compensating for the errors in the secondary current caused by CT saturation and the remanent flux. The algorithm compensates the distorted current irrespective of the level of the remanent flux. The second-difference function of the current is used to detect when the CT first starts to saturate. The negative value of the second-difference function at the start of saturation, which corresponds to the magnetizing current, is inserted into the magnetization curve to obtain the core flux at the instant. This value is then used as an initial flux to calculate the actual flux of the CT during the course of the fault with the secondary current. The magnetizing current is then estimated using the magnetization curve and the calculated flux value. The compensated secondary current can be estimated by adding the magnetizing current to the secondary current. Test results indicate that the algorithm can accurately compensate a severely distorted secondary current signal.

Characteristics of Heat Flux in Intake and Exhaust Valve of Methanol Fueled Engine (메탄올기관과 흡.배기 밸브에서의 열유속 특성)

  • 김문헌;임연기;이종태
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.1
    • /
    • pp.208-217
    • /
    • 1996
  • Instantaneous surface temperature and unsteady heat flux of intake and exhaust valve in methanol fueled engine were investigate as a function of compression ratio and engine speed. To accomplish this purpose, the instantaneous temperature sensor was designed and it was installed into three point of intake and exhaust valve head to measure unsteady temperature. The unsteady heat flux at valves was evaluated using one dimensional heat conduction equation with the valve head temperature and temperature gradient. And also mean heat flux of intake and exhaust valve for each stroke were evaluated as a function of engine speed.

  • PDF

Indirect Detection of Rotor Position of Switched Reluctance Motor Based on Flux Linkage Analytic Model

  • Zhou, Yongqin;Hu, Bo;Wang, Hang;Jin, Ningzhi;Zhou, Meilan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.829-837
    • /
    • 2018
  • In this paper, a flux linkage model based on four magnetization curves fitting is proposed for three-phase 12/8 switched reluctance motor (SRM), with the analysis of the basic principle of flux detection method and function analysis method. In the model, the single value function mapping relationship between position angle and flux is established, which can achieve a direct estimation of rotor position. The realization scheme of SRM indirect position detection system is presented. It is proved by simulation and experiment that the proposed scheme is suitable for rotor position detection of SRM, and has high accuracy of position estimation.

Sensorless Control of Brushless DC Motors based on TMS320F2812

  • Wu, Ziyu;Wang, Haifeng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • A new sensorless control strategy for brushless DC (BLDC) motors is proposed in this paper. This technique builds a rotor position-related flux function, which is independent of the speed. By observing the flux function, the information of rotor position and commutation can be obtained. As the function is not speed-related, this control process can be used in a wider range of speed and improves the motor's performance during startup. An experimental test bad based on TMS320F2812 has been built, and the experimental result indicates that the motor achieves a smooth starting-up and stable phase commutation with the proposed control strategy.

Development of a High-Order Accurate Hybrid Scheme Using the Central Flux and WENO Schemes (Central Flux Scheme과 WENO Scheme을 이용한 고차 정확도 Hybrid Scheme의 개발)

  • Kim D.;Kwon J. H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.135-141
    • /
    • 2005
  • A hybrid central-WENO scheme is proposed. The fifth order WENO-LF scheme is coupled with a central flux scheme at cell face. Two sub-schemes, the WENO-LF scheme and the central flux scheme, are switched by a weighting function. The efficiency and accuracy of the proposed hybrid central-WENO scheme is validated through several numerical experiments.

  • PDF

Modeling of flux enhancement in presence of concentration polarization by pressure pulsation during laminar cross flow ultrafiltration

  • Kumar, Kamal;De, Sirshendu
    • Membrane and Water Treatment
    • /
    • v.1 no.4
    • /
    • pp.253-271
    • /
    • 2010
  • A theoretical study for the flux enhancement by pulsation of transmembrane pressure is presented for osmotic pressure controlled ultrafiltration under laminar flow regime. The transient velocity profile is solved analytically using Green's function method. Time dependent convective diffusive equation is solved to quantify the membrane surface concentration and the permeate flux, numerically. The effects of the amplitude and frequency of pulsation on flux, surface concentration and observed retention are studied.