• Title/Summary/Keyword: Flux Leakage

Search Result 313, Processing Time 0.025 seconds

Characteristics Magnetic Flux Leakage According to the Position of Hall Sensor (Hall 센서 위치에 따른 MFL 특성 고찰)

  • Kim, Sean;Lee, Hyang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.819-821
    • /
    • 2001
  • This paper describes a characteristics of MFL according to the position of Hall sensor Magnetic Flux Leakage(MFL) Method is used to detect surface defect in ferromagnetic plate. A plate has a surface defect and magnetizing equipment are producted to perform Non-Destructive Testing(NDT) using MFL. The SM 45C carbon steel plate is adopted to this experiment. there is a artifical defect with a twice of thickness and a half of depth of plate. Magnetizing equipment is composed of yoke made by layer-built of silicon sheet steel, NdFeB magnetic and iron brushes. Detecting defect is performed by MFL NDT using Hall sensor. It is shown that magnetic flux detected by Hall sensor is affected according to the position of Hall sensor through MFL experiment and numerical analysis.

  • PDF

Modeling of Inductive Position Sensor and its Analysis (유도형 변위 센서의 모델링 및 해석)

  • 신우철;홍준희;이동주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.249-252
    • /
    • 1997
  • The resolution of analog sensor is determined by its sensitivity and amplitude of noise. This paper presents modeling of inductive gap sensor base on equivalent magnetic circuit and analysis of sensitivity. The model of inductive gap sensor is verified by the experimental results. Then we can simulate static characteristic of inductive gap sensor using this model. Computer simulation show that sensor's sensitivity and linearity are affected by magnetic flux's leakage and fringing, and that they are affected by shape of sensor probe.

  • PDF

Analysis of Single-phase Induction Motor Having Space Harmonics in Its Magnetic Field (고주파자속을 고려한 단순상유도전동기의 해석)

  • Keung Yul Oh
    • 전기의세계
    • /
    • v.22 no.3
    • /
    • pp.25-34
    • /
    • 1973
  • In this paper, the characteristics of a single phase induction motor which is considered the space harmonic flux by the double revolving field theory is analysed. As the rotor resistance for the fundamental flux is separated from the resistance for the rotor bar and end-ring, and the rotor leakage reactnace is separated from the skew leakage reactance and the other, so the circuit constants for the space harmonic flux is expressed by the circuit constants for the fundamentals. As the ratio of the circuit constants for the magnetizing reactance is used, the generalized equivalent circuit is made up. the characteristic equation which is able to analysis the subdivided characteristics by the above circuit is induced. The ratio of the circuit constants and the skew angle being changed, the variations of the torque-speed characteristics for the fundamentals and harmonics is examined by this equation.

  • PDF

Non-destructive Testing and Numerical Analysis for Ferromagnetic Plates using Magnetic Flux Leakage Method (강자성체 평판의 자속 누설 탐상 비파괴 실험 및 수치해석)

  • Kim, Sean;Lee, Hyang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.126-128
    • /
    • 2001
  • In this paper, Magnetic Flux Leakage(MFL) method is used to detect surface defect in ferromagnetic plate. Surface defects are created on the SM 45C ferromagnetic plate and magnetizing equipment is composed to perform MFL nondestructive testing. The length and width of defect is twice the thickness of ferromagnetic plate, and defects with different depths are made artificially for the experiment. Also, NdFeB magnet in magnetizing equipment is used to make magnetic flux. This paper shows that it is possibile to detect 10% defect and to analyze numerically for any defect using MFL method.

  • PDF

Inspection of Non-metallic Inclusions in Thin Steel Sheets Using Magnetic Flux Leakage Method (누설자속법을 이용한 박강판의 결함탐상)

  • 임종수;손대락
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.6
    • /
    • pp.302-309
    • /
    • 2000
  • An MFL (Magnetic Flux Leakage) testing system has been developed in order to inspect the non-metallic inclusions in the thin steel sheets. We have made a differential type flux-gate magnetometer using the measurement of apparent coercive field strength of soft magnetic core. The specifications of the electromagnet was determined using FEM software, and MFL testing system with 3 axis degree of freedom was constructed. The feasibility testing for non-metallic inclusion was shown using the system. By digitizing MFL signal and using 2-D graphic display, we could identify various surface defects other than the inclusions.

  • PDF

A Study of Stator Fault Detection for the Induction Motor Using Axial Magnetic Leakage Flux (축방향 누설자속 측정에 의한 유도전동기의 고정자 결함검출에 관한 연구)

  • Shin, Dae-Cheul;Kim, Young-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.131-137
    • /
    • 2005
  • The purpose of this paper is to evaluate the axial magnetic flux measurement could be used as a tool of the condition monitoring system for the induction motor and to develope the diagnostic algerian for the electric motors. The magnetic leakage flux signal is captured by the flux coil located at the end of motor without the disturbance of the operation. And the signal is analyzed both time and frequency bases to detect the failure of the motor. Specific signature can be described in time and frequency domain for each faults of the motor. The spectrum of the signal was found more useful for the monitoring purpose. The supply voltage imbalance and tin to turn failure of the stator winding could be detected by analysing the specific sidebands of the axial flux and sideband of the rotor bar pass frequency with the high resolution spectrum. The goal of this study verity that the axial flux measurement for the induction motor is a powerful tool for the diagnostic method and develope the algorithm to detect the fault.

단선 누전에 의한 표면자계 특성

  • O, Yong-Cheol;Choe, Mi-Hui;Jeong, Han-Seok;Kim, Jin-Sa;Jo, Chun-Nam;Kim, Chung-Hyeok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.148-148
    • /
    • 2009
  • In order to investigate the quality in compliance with an electric leakage electric current from the electric leakage area after conferring the electric leakage environment in compliance with a flooding when the electric leakage electric current exists in the surface, it investigated the electric leakage electric current quality from the electric current distribution and flooded districts from the present paper. At the result, we have known that flux density is constant regardless of distance variation.

  • PDF

Equivelent Circuit of Leakage Transformer using coupling Coefficient K (종합계수 K에 의한 누설변압기의 등가회로)

  • 이광직;공휘식;김주홍
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.3
    • /
    • pp.50-56
    • /
    • 1992
  • The coupling coefficient K controls the characteristic behaviors of leakage transformer. The value of coupling coefficient K was obtained from th leakage flux of leakage transformer an ascertained from the variation due to the function of current. Therefore, this paper presented the equivalent circuit of leakage transformer consisting of Thevenin's constant voltage source and inductor as (1-K2)L2 which were proportional to parameter K. The proposed equivalent circuit verified the validity in designing the leakage transformer because it was in good agreements of the behaviors of ideal transformer (K is 1), leakage transformer (K is 0$\leq$K$\leq$1), inductor (K is 0).

  • PDF

Iron Core Design of 3-Phase 40MVA HTS Power Transformer Considering Voltages per Turn

  • Lee, Chan-joo;Seok, Bok-yeol
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.2
    • /
    • pp.54-58
    • /
    • 2004
  • This paper presents the iron core design method of a high temperature superconducting (HTS) transformer considering voltages per turn (V/T). In this research, solenoid type HTS coils were selected for low voltage (LV) winding and double pancake coils for high voltage (HV) winding, just as in conventional large power transformers. V/T is one of the most fundamental elements used in designing transformers, as it decides the core cross sectional area and the number of primary and secondary winding turns. By controlling the V/T, the core dimension and core loss can be changed diversely. The leakage flux is another serious consideration in core design. The magnetic field perpendicular to the HTS wire causes its critical current to fall rapidly as the magnitude of the field increases slowly. Therefore in the design of iron core as well as superconducting windings, contemplation of leakage flux should be preceded. In this paper, the relationship between the V/T and core loss was observed and also, through computational calculations, the leakage magnetic fields perpendicular to the windings were found and their critical current decrement effects were considered in relation to the core design. The % impedance was calculated by way of the numerical method. Finally, various models were suggested.

Analysis of Electric Shock Risk of the Human Body in Underwater (수중에서의 인체에 대한 전격위험성 분석)

  • Kim, Sung-Chul;Kim, Doo-Hyun;Lee, Chong-Ho;Kim, Chong-Min
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.6 s.78
    • /
    • pp.26-32
    • /
    • 2006
  • The paper considers the electrical shock risk of the human body due to underwater leakage current in electric field. The characteristics of electric shock in fresh water due to the leakage of submerged electric facility in the bathtub in public baths were conducted. The exposed live electrode is modeled as a point source of electric current source. It is assumed that divergent monopole field exists in the vicinity of the current source, regardless of the presence of return electrode and insulating boundary. The electric potentials in the steel bathtub, Diesen and Mole and Flux3D program one are measured according to the distance from leakage source. The results show that the increased shock risk and safe distance are estimated by the bathtub of limited width and the voltage calculated on the basis of a divergent monopole field concept is compared with the measured value.