• Title/Summary/Keyword: Flush-out

Search Result 79, Processing Time 0.023 seconds

A study on TDC crank angle determination by motoring pressure measurement (모터링 압력측정을 통한 상사점 결정방법에 관한 연구)

  • 한정옥;이영주;김승수
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.6
    • /
    • pp.39-47
    • /
    • 1988
  • A disk photo sensor system was constructed and installed on engine for the crank angle measurement. Statically measured TDC crank angle data were compared with those obtained from engine motoring. Two groups of cylinder pressure data were compared each other, one measured by pressure transducer mounted flush on the combustion chamber and the other obtained with the help of spark plug type adaptor. A simple analysis on the gas flow in the spark plug type pressure transducer displayed reasonably good agreement with those from engine motoring tests. In various firing tests, the IMERs obtained from the spark plug type pressure transducer turned out to be higher than those from the flush mounted one at low engine speed while those two were nearly the same at high engine speed. As the engine load decreased the relative difference in IMEP measurement between the two types tended to be enlarged.

  • PDF

Behaviour of flush end-plate beam-to-column joints under bending and axial force

  • da Silva, Luis Simoes;de Lima, Luciano R.O.;da S. Vellasco, Pedro C.G.;de Andrade, Sebastiao A.L.
    • Steel and Composite Structures
    • /
    • v.4 no.2
    • /
    • pp.77-94
    • /
    • 2004
  • Steel beam-to-column joints are often subjected to a combination of bending and axial forces. The level of axial forces in the joint may be significant, typical of pitched-roof portal frames, sway frames or frames with incomplete floors. Current specifications for steel joints do not take into account the presence of axial forces (tension and/or compression) in the joints. A single empirical limitation of 10% of the beam's plastic axial capacity is the only enforced provision in Annex J of Eurocode 3. The objective of the present paper is to describe some experimental and numerical work carried out at the University of Coimbra to try to extend the philosophy of the component method to deal with the combined action bending moment and axial force.

A Novel Integration Mechanism of FMIPv6 and HMIPv6 to Reduce Loss and Out-of-Sequence Problem (패킷 손실과 순서 어긋남 문제를 해결할 수 있는 새로운 FMIPv6와 HMIPv6 통합 메커니즘)

  • Lee, Jae-Hwoon;Lim, Yu-Jin
    • Journal of KIISE:Information Networking
    • /
    • v.34 no.2
    • /
    • pp.110-119
    • /
    • 2007
  • Mobile IPv6 (MIPv6) enables a mobile node (MN) to maintain its connectivity with a correspondent node (CN) while changing its point of attachment. In MIPv6, packets sent from a CN to a MN during handover are lost. Several mechanisms including FMIPv6 and HMIPv6 have been proposed in order to minimize packet loss. However, such mechanisms still suffer from performance degradation due to not only packet loss but also out-of-sequence packets. In this paper, we propose I-FHMIPv6 to resolve packet loss as well as the out-of-sequence packet problem. In I-FHMIPv6, the flush message is newly defined in order to notify a home agent (HA) or CN of the fact that the binding cache entry of a MN is about to be updated. A MN receiving the flush message can know that there is no more packets transmitted via the previous route, which resolve the out-of-sequence packet problem. Moreover, with the proposed mechanism, we can minimize packet loss by integrating FMIPv6 and HMIPv6 efficiently. I-FHMIPv6 is evaluated by performing simulations, and the simulation results show that I-FHMIPv6 outperforms FMIPv6 and HMIPv6.

Analysis of Storm Water Run-off Characteristics to Evaluate the Intercepted Volume of CSOs during Wet Weather (강우시 합류식 하수관거의 월류수 차집용량 산정을 위한 유출특성 분석)

  • Choi, Sung-Hyun;Choi, Seung-Chol;Kim, Byoung-Ug;Rim, Jay-Myoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.320-330
    • /
    • 2004
  • Most of domestic city is served combined sewer system among various sewer system like as separate sanitary, combined sewer system and storm sewers. During the wet weather, sewer and rainfall have been overflowed because it is over capacity of the combined sewer system; that is called combined sewer overflows(CSOs) This research was carried out to investigate runoff characteristics of combined sewer and to evaluate the effective CSOs volume in Hong-Chun gun. During wet weather, SS load of first rainfall at H-1, H-2, and H-3 were 600kg/event, 370kg/event, and 289kg/event, respectively. 55 load of second rainfall were 216kg/event, 113kg/event, and 37.2kg/event. When the first rainfall, event mean concentrations(EMCs) at each site were 702mg/L, 816mgjL and 861.5mg/L. The second rainfall's event mean concentrations(EMCs) were 99.9gm/L, 161.9mg/L, 103.6mg/L. Rrst flush coefficient b at each site were 0.237,0.166, and 0.151. When the first rainfall, the flow containing 80% of pollutant mass of CSOs at each site were 0.55, 0.23, 0.48 in first rainfall, respectively. The case of second rainfall were 0.79, 0.83, 0.81. Most of all, characteristics of rainfall like as analysis of first-flush, CSOs volume, pollutant loadings is investigated to decide intercepted volume for control of CSOs.

Analysis of Suspended Solid Generation with Rainfall-Runoff Events in a Small Forest Watershed (산림 소유역에서 강우-유출에 따른 부유토사 발생 특성 분석)

  • Kim, Jae-Hoon;Choi, Hyung-Tae;Lim, Hong-Geun
    • Journal of Environmental Science International
    • /
    • v.24 no.12
    • /
    • pp.1617-1627
    • /
    • 2015
  • This study was carried out to investigate the characteristics of suspended solid concentration in small forest watershed, Hwacheon, Gangwondo. For five rainfall events from July 2013 to August 2013, rainfall, discharge, and suspended solid load has been measured. The results showed that the fist flush effect was observed for suspended solid in each rainfall event, sediment rating curve was obtained with $y=30.029x^{1.573}$ at rising limb and $y=12.902x^{1.8827}$ at falling limb, and EMC (event mean concentration) of suspended solid was calculated to 9.4 mg/L. EMC was compared to the values from the watershed that has various land use types and EMC from forest watershed was much lower that from the crop, paddy or low covered forest watershed.

The optimal array of various heat-generating heaters located on one wall of a vertical open top cavity (상부가 개방된 수직 캐비티내의 한쪽면에 배열된 다양한 발열조건을 갖는 발열체의 최적배열)

  • Riu, Kap-Jong;Choo, Hong-Lock;Choi, Byung-Cheol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.1
    • /
    • pp.15-23
    • /
    • 1997
  • An experimental investigation of two-dimensional steady natural convection cooling in a vertical open top cavity with conducting side walls of finite thickness is presented. The various heat-generating discrete heaters are located on one vertical wall of the cavity. When each heater dissipates different amount of power, the purpose of the work is to obtain the optimal array condition of the heaters. The four cases of non-uniform heating conditions are considered. The temperature fields in the cavity were visualized by the interferometer and local temperatures of the vertical wall were measured by thermocouples. The heaters were arranged in two configurations: flush-mounted on a vertical wall or protruding from the wall about 4.5 mm. The vertical wall was constructed out of copper or epoxy-resin sheet. Experiments have been conducted for air with constant Prandtl number(Pr=0.7), the aspect ratio of 4.6, 7.5, 9.5, power input in the range of 0.9 W ~ 4.2 W. For the enhancement of the cooling effectiveness, the upper and lower of vertical wall would give the better position for the heaters of higher heat flux.

Development of Optimal Septic Tank in the Countries of Water Shortages (물 부족국가에서 활용가능한 정화조의 최적모형 개발)

  • Lim, Bong-Su;Jing, Hai-Long
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.4
    • /
    • pp.418-427
    • /
    • 2015
  • This study was carried out to evaluate the performance of a lab-scale novel septic tank system for improving the conventional septic tank in the developing countries of water shortages. The lab-scale novel septic tank system consists of sepetic tank, aeration tank with HBC-ring, and sand filter. Optimum HRT was reguired about 1.5days to get a total COD removal efficiency of 90%, COD, BOD and SS removal efficiency was about 70%, 60%, and 85% in sepetic tank only. The structure of sepetic tank with two stages results in the high removal efficiency of organic matter. When sepetic tank, aeration tank, and sand filter were more than HRT 1.5days, 18hrs, and 12hrs, respectively, final effluent was less than 20 mg/L of BOD, 14 mg/L of SS, so that there is a high potential of its use for reusing water in flush toilet. There is no significant effect of HRT change on nutrient removal. Total nitrogen removal efficiency was about 40%, final effluent was 30~40 mg/L of TN, total phosphorus removal efficiency was about 11~25%, final effluent was 9~12 mg/L of TP. Because there is very small amounts of organic nitrogen and phosphorus in effluent, it was possible to reuse water for agricultural use.

An Analysis of First Flush Phenomenon of Non-point Source Pollution during Rainfall-Runoff Events from Impervious Area (불투수성 지역의 강우유출수에 대한 비점오염물질의 초기유출현상 분석)

  • Ahn, Tae-Ung;Bum, Bong-Su;Kim, Tae-Hoon;Choi, I-Song;Oh, Jong-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.9
    • /
    • pp.643-653
    • /
    • 2013
  • In this study, trend analysis was performed by various runoff analysis method of Non-point Pollution Source(NPS) at the impervious area. The characteristics of rainfall at impervious area appeared to be influenced by rainfall strength and it appeared that first flush phenomenon occurs often if rainfall strength acts largely. It is judged that the measure is required to be prepared against that now that concentration difference of non-point pollution source appeared to be big by precedent number of days of no rainfall. As the result of calculating Decrease Rate (DR) by first flush of non-point pollution source, it is judged that it is important to prepare the measure against the pollutants about initial rain and it is necessary to calculate the capacity of non-point pollution source processing facilities regarding that now that the non-point pollution source integrated at impervious area showed the characteristics that are flowed out in high concentration by initial rain in case of non-rainfall considering the characteristics of non-point pollution source at impervious area. When taking 50% of non-point pollution source as the standard for decrease rate that was evaluated previously, it appeared as 15~60 min in case of TSS and it appeared as 30~90 min in case of organic compound, but the characteristic whose decrease rate is below 50% also appeared even till rainfall-runoff ends. Based on that, it is judged that it could be used as the reference when designing the structural BMPs facilities later.

The difference of occurring pattern of Hericium erinaceus by pinheading induction methods (노루궁뎅이버섯(Hericium erinaceus) 봉지재배시 발이유도 처리방법에 따른 자실체 발생양상)

  • Kang, Min-Gu;Jo, Woo-Sik;Kim, Woo-Hyun;Choi, Seong-Yong;Park, So-Deuk
    • Journal of Mushroom
    • /
    • v.13 no.1
    • /
    • pp.11-15
    • /
    • 2015
  • In recent years, Hericium erinaceus became famous for comsumer because it contains some materials to assist in human health. This study was carried out to find the difference of occurring pattern of H. erinaceus by pinheading induction methods. Harvest period of T1, T2 treatments were longer than T3~T6. All treatments fresh weights were not significantly different, but T3, T6 treatments's dry weight in 2nd flush were lower than others. T5 treatment's 2nd flush's regeneration rate was the highest than others and looks best quality. Therefore, it is suggested that pinheading induction method would be changed not T1, T2 treatment which were used some farm as Pluerotus ostreatus cultivation, but to scratch surface method which is T5 treatment for cultivation of high quality H. erinaceus.

The apartments model house bathroom chatacteristics of plane composition classified by 'pyeong' on Seoul (서울지역 아파트 모델하우스 욕실의 평형대별 평면구성)

  • Chung, Hoe-Jin;Shin, Kyung-Joo
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2004.05a
    • /
    • pp.123-126
    • /
    • 2004
  • This study aims to identify the change of bathroom design characteristics through the investigation of bathroom space in apartment model houses. The bathroom space of each private exclusive area was analyzed from the plane characteristics perspective such as quantity, location, size and shape. For this study, site survey and observation was performed to analyze the characteristics of plane and design based on twenty seven model houses of seven large-sized construction firms with Seoul area focused on. Research object was restricted to from ten Pyeong's apartment to sixty Pyeong's in order to understand various characteristics of twenty seven model houses. Since analysis variables were not diverse, the main three factors - frequency, percentage and an average - were represented in Microsoft Excel worksheet, focusing on the quantity of each case, design characteristics and pattern. 1) The quantity of bathrooms: It was turned out that the quantity of bathroom was one in ten Pyeong's apartment while it was two in thirty, forty, and fifty Pyeong's apartment. There were mostly two bathrooms available in twenty Pyeong's apartment even if only one was planned in few cases. All powder rooms and dress rooms in twenty and fifty Pyeong's apartment were designed to be separated and be accessible through bedroom. 2) The size of bathrooms: As private exclusive area increased, the size of bathroom for both family and couple increased. Couple bathrooms had the tendency to be equipped with shower booth and bathtub at the same place or have more tubs than family bathrooms because couple bathrooms were bigger than family bathrooms. 3) The location of bathrooms: Couple bathrooms were usually located beyond dress rooms or powder rooms while family bathrooms were mostly located at the entrance side. 4) The shape of bathrooms: Shower booth was assumed to be in general vogue because family bathrooms, for the most part, were comprised of a flush toilet, a washstand and a shower booth. In the case of couple bathrooms, a flush toilet, a washstand, a shower booth and a tub were generally equipped in more than twenty Pyeong's apartments while a tub was not installed in twenty Pyeong's apartments.

  • PDF