• Title/Summary/Keyword: Fluorimeter

Search Result 4, Processing Time 0.018 seconds

Oil Fluorescence Spectrum Analysis for the Design of Fluorimeter (형광 광도계 설계인자 도출을 위한 기름의 형광 스펙트럼 분석)

  • Oh, Sangwoo;Seo, Dongmin;Ann, Kiyoung;Kim, Jaewoo;Lee, Moonjin;Chun, Taebyung;Seo, Sungkyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.4
    • /
    • pp.304-309
    • /
    • 2015
  • To evaluate the degree of contamination caused by oil spill accident in the sea, the in-situ sensors which are based on the scientific method are needed in the real site. The sensors which are based on the fluorescence detection theory can provide the useful data, such as the concentration of oil. However these kinds of sensors commonly are composed of the ultraviolet (UV) light source such as UV mercury lamp, the multiple excitation/emission filters and the optical sensor which is mainly photomultiplier tube (PMT) type. Therefore, the size of the total sensing platform is large not suitable to be handled in the oil spill field and also the total price of it is extremely expensive. To overcome these drawbacks, we designed the fluorimeter for the oil spill detection which has compact size and cost effectiveness. Before the detail design process, we conducted the experiments to measure the excitation and emission spectrum of oils using five different kinds of crude oils and three different kinds of processed oils. And the fluorescence spectrometer were used to analyze the excitation and emission spectrum of oil samples. We have compared the spectrum results and drawn the each common spectrum regions of excitation and emission. In the experiments, we can see that the average gap between maximum excitation and emission peak wavelengths is near 50 nm for the every case. In the experiment which were fixed by the excitation wavelength of 365 nm and 405 nm, we can find out that the intensity of emission was weaker than that of 280 nm and 325 nm. So, if the light sources having the wavelength of 365 nm or 405 nm are used in the design process of fluorimeter, the optical sensor needs to have the sensitivity which can cover the weak light intensity. Through the results which were derived by the experiment, we can define the important factors which can be useful to select the effective wavelengths of light source, photo detector and filters.

Principles and Analytical Applications of Acousto-Optic Tunable Filters

  • Tran, Chieu D.
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.1101-1108
    • /
    • 1995
  • Acousto-optic tunable filter is a compact, all solid state electronic dispersive device. It is based on the acousto-optic interaction in an anisotropic crystal. Compared to conventional grating monochromators. the AOTF has no moving parts, wider spectral tuning range (from UV through visible and near-IR to IR), higher throughput, higher resolution, faster scanning (${\mu}s$) and random wavelength access. These features make it possible to use the filter to develop novel instruments which are not possible otherwise. The instrument development and unique advantages of such AOTF based instruments including the multidimensional fluorimeter, the multiwavelength thermal lens spectrometer, and the detectors for HPLC and flow injection analysis are described.

  • PDF

An Apparatus for Monitoring Real-time Uranium Concentration Using Fluorescence Intensity at Time Zero

  • Lee, Sang-Mock;Shin, Jang-Soo;Kang, Shin-Won
    • Nuclear Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.166-174
    • /
    • 2001
  • An apparatus for detecting remote real-time uranium concentration using an optrode was developed. An optrode to detect uranium fluorescence as remote real-time control was designed. Fluorescence intensity at time 2ero was derived by the fluorescence signal processing and the algorithm to exclude the quenching effect of various quenchers and temperature fluctuations. This apparatus employing the above deriving method and the optrode has an error range within 6% in spite of serious fluorescence lifetime changes due to the quenching effect and temperature fluctuations. The detection limit is 0.06 ppm and the linearity is excellent between 0.06 ppm and 2 ppm on the aqueous uranium solution.

  • PDF

A Drug Efflux Pump for Cationic Drugs including Disinfectants in Bacillus subtilis (양이온약제내성을 유도하는 Bacillus subtilis의 Drug Efflux Pump)

  • Yong Joon Chung
    • Microbiology and Biotechnology Letters
    • /
    • v.31 no.3
    • /
    • pp.230-234
    • /
    • 2003
  • The Bacillus subtilis YvaE protein, the small multidrug resistance (SMR) family (TC #2.A. 7.1), is shown to catalyze efflux of multiple cationic drugs including many disinfectants, when it was cloned and expressed in Escherichia coli. When the yvaD gene was coexpressed with yvaE gene, the yvaD protein, encoded within a single operon with the yvaE gene, is shown to counteract the action ofYvaE. By ethidium efflux analysis, the cells harvoring a vector with yvaE gene showed a rapid ethidium efflux, compared with the control cells. These results clearly suggest that YvaE mediates drug export from the cell cytoplasm.