• Title/Summary/Keyword: Fluorescence method

Search Result 1,013, Processing Time 0.03 seconds

Plasma Density Measurement of the Hg-Ar(1Torr) by LIF Method (LIF를 이용한 Hg-Ar(1Torr)의 플라즈마 밀도 측정)

  • Lee Jong-Chan;Park Dae-Hee;Yang Jong-Kyung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.5
    • /
    • pp.213-217
    • /
    • 2005
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. Due to this generation, the extinction of atoms in a metastable state occurred through collision, ionization, and excitation between plasma particles. The density and distribution of the metastable state depended on the energy and density of plasma particles, intensely This highlights the importance of measuring density distribution in plasma electric discharge mechanism study The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength change, and also confirmed that the largest fluorescent signal in 436nm, and that the density of atoms in 546.2nm ($6^3S_1 {\to} 6^3P_2$ ) were larger than 404.8nm ($6^3S_1 {\to} 6^3P_1$). According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the LIF signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

Plasma Density Measurement of Hg-Ar by LIF Method (LIF를 이용한 Hg-Ar의 플라즈마 밀도 측정)

  • Choi, Yong-Sung;Hwang, Jong-Sun;Park, Kye-Choon;Song, Min-Jong;Kim, Hyeong-Gohn;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.27-32
    • /
    • 2006
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. Due to this generation, the extinction of atoms in a metastable state occurred through collision, ionization, and excitation between plasma particles. The density and distribution of the metastable state depended on the energy and density of plasma particles, intensely. This highlights the importance of measuring density distribution in plasma electric discharge mechanism study. The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength change, and also confirmed that the largest fluorcscent signal in 436nm, and that the density of atoms in 546.2nm ($6^3S_1{\rightarrow}6^3P_2$) were larger than 404.8nm ($6^3S_1{\rightarrow}6^3P_2$). According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the LIF signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

  • PDF

Frequency of Chromosome Aberrations Detected by Fluorescence in Situ Hybridization Using Triple Chromosome-Specific Probes in o Healthy Korean Population (3중 염색체 probe를 이용한 FISH(fluorescence in situ hybridization)기법으로 분석한 정상인의 염색체 이상빈도)

  • 정해원;김수영;신은희
    • Environmental Mutagens and Carcinogens
    • /
    • v.18 no.2
    • /
    • pp.109-115
    • /
    • 1998
  • Fluorscence in situ hybridization with chromosome-specific probe has been shown to be a valid and rapid method for detection of chromosome rearrangements induced by chemical and physical agents. This method is useful for quantifying structural aberrations, expecially for stable ones, such as translocation and insertion, which are difficult to detect with conventional method in human lymphocyte. In order to use the FISH method as a biodosimeter for monitoring human population exposed to various chemical and physical agent, baseline level of chromosome rearragement was established. Blood from forty four healthy adults were collected and analysed with whole chromosome-specific probes by human chromosome 1,2 and 4. The frequencies of stable translocation were 2.45 per 100 cell equivalent and those of insertion, color juction, acentric and dicentric were 0.32, 3.28, 0.23 and 0.27 per 100 cell equivalent respectively. The frequencies of chromosome rearragements increased with age in both sexes except for dicenrics. From above result, stable aberrations accumulate with age and it may reflect integrated lifetime exposure of adverse environment.

  • PDF

Detection of Cryptosporidium oocysts from out-patients of the Severance Hospital, Korea (연세대학교 세브란스병원 환자에서의 Cryptosporidium 오오시스트 검출률)

  • Jo, Myeong-Hwan;Kim, Ae-Gyeong;Im, Gyeong-Il
    • Parasites, Hosts and Diseases
    • /
    • v.31 no.3
    • /
    • pp.193-200
    • /
    • 1993
  • A total of 230 randomly collected formalin-fixed fecal samples (submitted to the Severance Hospital, Yonsei University) were selected for tests for human cryptosporidiosis. The stool specimens were examined for Cwptosporidium oocysts by acid-fast (AF) stain, auramin-rhodamine (AR) stain, and monoclonal antibody (mAb) OW3 fluorescence method specific for oocyst wall. Of the 230 stool specimens, 21% were identified by the AF method, 22% were identified by the AR method, and 10% were Identified by the mob fluorescence method, indicating that human Crvptosporidium infections have been existing in Korea.

  • PDF

A Simple Method for Combined Fluorescence In Situ Hybridization and Immunocytochemistry

  • Moon, Il Soo;Cho, Sun-Jung;Jin, IngNyol;Walikonis, Randall
    • Molecules and Cells
    • /
    • v.24 no.1
    • /
    • pp.76-82
    • /
    • 2007
  • By combining in situ hybridization (ISH) and immunocytochemistry (IC), microscopic topological localization of mRNAs and proteins can be determined. Although this technique can be applied to a variety of tissues, it is particularly important for use on neuronal cells which are morphologically complex and in which specific mRNAs and proteins are located in distinct subcellular domains such as dendrites and dendritic spines. One common technical problem for combined ISH and IC is that the signal for immunocytochemical localization of proteins often becomes much weaker after conducting ISH. In this manuscript, we report a simplified but robust protocol that allows immunocytochemical localization of proteins after ISH. In this protocol, we fix cultured cortical or hippocampal neurons with 4% paraformaldehyde (PFA), rinse briefly in PBS, and then further fix the cells with $-20^{\circ}C$ methanol. Our method has several major advantages over previously described ones in that (1) it is simple, as it is just consecutive routine fixation procedures, (2) it does not require any special alteration to the fixation procedures such as changes in salt concentration, and (3) it can be used with antibodies that are compatible with either methanol (MeOH-) or PFA-fixed target proteins. To our best knowledge, we are the first to employ this fixation method for fluorescence ISH + IC.

Highly Sensitive and Naked Eye Dual-readout Method for ʟ-Cysteine Detection Based on the NSET of Fluorophore Functionalized Gold Nanoparticles

  • Fu, Xin;Liu, Yuan;Wu, Zhitao;Zhang, He
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.4
    • /
    • pp.1159-1164
    • /
    • 2014
  • A simple, highly sensitive and selective method based on the rhodamine B-covered gold nanoparticle with dual-readout (colorimetric and fluorometric) detection for $\small{L}$-cysteine is proposed. A mechanism is that citrate-stabilized AuNPs were modified with RB by electrostatic interaction, which enables the nanometal surface energy transfer (NSET) from the RB to the AuNPs, quenching the fluorescence. In the presence of $\small{L}$-cysteine, it was used as a competitor in the NSET by the strongly Au-S bonding to release RB from the Au surface and recover the fluorescence, and the red-to-purple color change quickly, which was monitored simply by the naked eye. Under the optimum conditions, the detection limit is as low as 10 nM. The method possessed the advantages of simplicity, rapidity and sensitivity at the same time. The method was also successfully applied to the determination of $\small{L}$-cysteine in human urine samples, and the results were satisfying.

A COMPARISON OF FLUORESCENCE EFFECT OF VARIOUS LIGHT SOURCES IN EARLY ENAMEL CARIES (초기 우식 병소에서 광원에 따른 형광효과 비교)

  • Jeon, Jeong-Hoon;Lee, Nan-Young;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.4
    • /
    • pp.611-619
    • /
    • 2005
  • The aim of this study was to apply the quantitative light-induced fluorescence(QLF) and use of fluorescein-enhanced QLF method for quantitative assessment of early enamel demineralization in vitro, comparing effectiveness of light sources : argon laser, halogen lamp, light emitting diode (LED) and plasma arc lamp. Sixty extracted teeth were used, prepared by gentle pumicing and coating in an acid-resistant nail-varnish, except for an exposure to a demineralizing solution. Teeth were removed at regular intervals (24, 48 and 72hrs), air-dried and QLF image were taken. Mineral loss, as measured by difference of optical density, was recorded. For dyeenhanced QLF a 0.075% sodium fluorescein dye was applied after QLF examination and mineral loss was recorded. The following result were obtained : 1. Comparing with mean difference of optical density, plasma arc lamp was higher than other light sources in all group (p<0.05). 2. Comparing each group with mean difference of optical density, there was significant different using plasma are lamp and halogen lamp. 3. For use of dye-enhanced QLF, comparing with mean difference of optical density, plasma arc lamp were higher than other light sources in all group(p<0.05). 4. With this model dye-enhanced QLF compared with QLF in optical density, dye-enhanced QLF was higher than QLF in optical density. From the results presented in this paper, it was concluded that plasma light source was more effective compared with other light source for the detection and the quantification of early enamel caries.

  • PDF