• Title/Summary/Keyword: Fluorescence method

Search Result 1,013, Processing Time 0.028 seconds

Time-resolved Fluoroimmunoassay for the Measurement of 17$\beta$-Estradiol using Anti-idiotypic Antibody (Anti-idiotype 항체를 이용한 17$\beta$-Estradiol 측정을 위한 Time-resolved Fluoroimmunoassay)

  • 김윤규;김창규;박성민;이치호;이원창;최영숙;김종배
    • Korean Journal of Animal Reproduction
    • /
    • v.16 no.4
    • /
    • pp.325-333
    • /
    • 1993
  • A competitive type immunoassay method for 17$\beta$-estradiol(E2) based on the idiotypic anti-idiotypic antibody and time-resolved fluorescence is described. The anti-idiotypic antibody(Ab2) produced to E2 binding site of the primary idiotype antibody (Ab1) was labelled with europium and was allowed to compete with E2 standards or serum sample for the binding sites of Ab1 which was bound to 2nd antibody captured ontothe surface of microtitre plates. Fluorescence measured by time-resolved fluorometer was inversely proportional to the concentration of E2 over the range 5~500pg/well. The sensitivity of the assay was 5pg per well which was compatible with that ofradioimmunoassay using the same Ab1 and 3H-E2 as a tracer. One great advantage of this method described here was to enable antibodies to be labelled instead of haptens, and thus makes it easier to develop sensitive and robust immunoassay systems specially for haptens.

  • PDF

Studies on Isolative Determination of dl- Methylephedrine hydrochloride from Complex Preparation (복합제제(複合製劑) 성분중(成分中) dl-Methylephedrine hydrochloride의 분리정량(分離定量))

  • Kim, Byung-Hi;Yong, Jae-Ick
    • Journal of Pharmaceutical Investigation
    • /
    • v.3 no.1_2
    • /
    • pp.5-15
    • /
    • 1973
  • Fluorometric determination of dl-Methylephedrine hydrochloride from complex preparation were studied. According to the experimental results and considerations obtained the results for the following. (1) dl-Methylephedrine hydrochloride in Hydrochloric acid media occurs the fluorescens by Picrolonic acid and Cuppric acetate. (2) The maximum absorption fluorescence wave length of dl-Methylephedrine hydrochloride standard solution is $365m{\mu}$. (3) The relationship between the fluorescence proportions to concentration of standard solution at range of $4.2{\times}10^{-4}\;M$. $6{\times}10^{-4}M$. (4) dl-Methylephedrine hydrochloride was precisely determined even in the presence of various components, especially Chloropheniramine maleate, Dextromethorphan hydrobromide and Diphenylhydramine hydrochloride. (5) This method has high sensitivity and is simple in precedure. (6) This method be applicable with 99.79% accuracy and was 99.5% in complex preparation.

  • PDF

Signal increasing method in confocal scanning microscopy in fluorescence mode using curved mirror

  • Kang, Dong-kyun;Seo, Jung-woo;Gweon, Dae-gab
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.99.3-99
    • /
    • 2001
  • In fluorescence mode confocal scanning microscope, level of detected signal is very low. In object scanning type confocal scanning microscope, the additional optical system with objective lens and plane mirror was proposed to increase signal intensity, but there was none for beam scanning type confocal scanning microscope. We propose reflecting optical systems which improve signal intensity in beam scanning type confocal scanning microscope. We choose one of the proposed optical systems and design the optical system, i.e., select optical components and assign distances between the selected components. To design the optical system, we use finite ray tracing method and make cost function to be minimized.

  • PDF

A Study on the Behavior Characteristics of Diesel Spray by Using a High Pressure Injection System with Common Rail Apparatus

  • Yeom, Jeong-Kuk;Hajime Fujimoto
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.9
    • /
    • pp.1371-1379
    • /
    • 2003
  • The effects of change in injection pressure on spray structure in high temperature and pressure field have been investigated. The analysis of liquid and vapor phases of injected fuel is important for emissions control of diesel engines. Therefore, this work examines the evaporating spray structure using a constant volume vessel. The injection pressure is selected as the experimental parameter, is changed from 22 MPa to 112 MPa using a high pressure injection system (ECD-U2). Also, we conducted simulation study by modified KIVA-II code. The results of simulation study are compared with experimental results. The images of liquid and vapor phase for free spray were simultaneously taken by exciplex fluorescence method. As experimental results, the vapor concentration of injected fuel is leaner due to the increase of atomization in the case of the high injection pressure than in that of the low injection pressure. The calculated results obtained by modified KIVA-II code show good agreements with experimental results.

Measurement of two dimensional oil film thickness in piston by induced fluorescence method (유기형광법을 이용한 피스톤 유막두께의 이차원적 측정)

  • 민병순;최재권
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.166-174
    • /
    • 1998
  • The distribution of oil film thickness in piston were measured by induced fluorescence method. A Xe lamp was used as light source. Coumarine-6 was mixed with oil as the fluorescent dye. Fluorescent signal which is proportional to the oil film thickness was acquired by CCD camera and transmitted to the personal computer as video signal. In order to solve the problem of measurement system, irregular distribution and unstability of light intensity, as well as to know the relationship between the oil film thickness and output signal, three different calibration techniques were used. Motoring and firing tests were performed in a single cylinder research engine with transparent liner. By analyzing the oil film thickness converted from the photographed image, it was observed that each of three piston rings scrapes the oil both upward and downward and oil film thickness is not uniform horizontally at a given piston land. The amount of oil in each land was considerably affected by the engine load. It is thought that the blow-by gas blows the oil down to the crankcase.

  • PDF

Comparison of methods for Determination of Aflatoxins in food Products (식품중 Aflatoxin 측정방법의 비교)

  • 김면희
    • Journal of Food Hygiene and Safety
    • /
    • v.11 no.2
    • /
    • pp.149-157
    • /
    • 1996
  • A procedure for the determination of Aflatoxins in food and grains which utilizes reversed phased liquid chromatographic (LC) analysis with postcolumn derivatization by an electrochemical cell and determination with a fluorescence detector has been evaluated. The LC mobile phase was water-acetonitrile-methanol (6+2+2) with 1mM KBr and 1 mM HNO3 which gave baseline separation for the four Aflatoxins (AfB1, AfB2, AfG1, AfG2). The electrochemical cell set at 7V, generated bromine and derivatized aflatoxins B1 and G1, The derivatives were detected by the fluorescence detector. The aflatoxins in naturally contaminated corn samples were isolated by three different cleanup procedures: the AOAC method I column(CB method), a rapid filtrate column (Romer's column), and an immunoaffinity column. The final extract were quantitated with fluordensitometric TLC and the LC postcolumn derivatization techniques. The results were quite similar, however the LC technique showed less interferences and could be automated. Samples of corn, raw peanuts, peanut butter and dried dates were also analyzed successfully with this procedure.

  • PDF

Effect of the Change in Injection Pressure on the Mixture Formation Process in Evaporative Free Diesel Spray (분사압력변화가 증발자유디젤분무의 혼합기형성과정에 미치는 영향)

  • Yeom, J.K.;Chung, S.S.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.214-219
    • /
    • 2005
  • The effects of change in injection pressure on spray structure in high temperature and pressure field have been investigated. The analysis of liquid and vapor phases of injected fuel is important for emissions control of diesel engines. Therefore, this work examines the evaporating spray structure using a constant volume vessel. The injection pressure is selected as the experimental parameter, is changed from 72MPa to 112MPa by using a common rail injection system(ECD-U2). The images of liquid and vapor phase in the evaporating free diesel spray are simultaneously taken by exciplex fluorescence method. As a result, it can be confirmed that the distribution of vapor concentration is more uniform in the case of the high injection than in that of the low injection pressure.

  • PDF

Research of Nd:LSB microchip laser (Nd:LSB 마이크로 칩 레이저 연구)

  • 장원권;김태훈;유영문
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.6
    • /
    • pp.554-558
    • /
    • 2002
  • A new laser material, Nd:LSB $(Nd${3}:LaSc_3(BO_3)_4$, lanthanum scandium borate), of microchip type was grown by the Czochralski pulling method, and tested for optical and lasing properties. Nd:LSB, able to be highly doped with $Nd^{3+}$ ions while maintaining good optical, chemical, mechanical properties, was compared to another Nd-type laser material. The absorption and fluorescence spectra, and fluorescence lifetime were measured, and the crystal structure was analyzed. The lasing characteristics were investigated by using Ti:sapphire laser as a pumping light source.

Spectrophotofluorometric analysis of 2-[[3-(Trifluoromethyl) pheny 1] amino]-3-pyridine carboxylic acid in urine

  • Lee, Kang-Choon;Min, Shin-Hong;Rhee, Shang-Hi;Lee, Yoon-Joong
    • Archives of Pharmacal Research
    • /
    • v.3 no.1
    • /
    • pp.17-21
    • /
    • 1980
  • A sensitive spectrophotofluorometric method was developed for the analysis of 2[[3-(trifluoromethyl)phenyl]amino]-3-phridine carboxylic acid (I) in urine. The method is based on the fluoroscence behavior of the I-aluminum complex in absolute ethanol. This fluorophore has activation and emission wavelengths of 355 and 450 nm, respectively. Optimum conditions for the reaction were investigated. The fluorescence was linear in the range of 0.25 3.0 ug of I/ml. Replicate studies of spiked urine samples, each containing 2.5 ug of I/ml showed good precision with a relative standard deviation of 0.019. Overall recovery percent from five spiked urine samples was 99.4 $\pm$1.32%.

  • PDF

Basic Study on the Application of a Computational Technique to Behavior Characteristics Analysis of the Evaporative Diesel Spray (증발디젤분무의 거동특성해석을 위한 계산기법 적용에 관한 기초 연구)

  • Yeom, J.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.6
    • /
    • pp.5-12
    • /
    • 2010
  • In this study, an analysis of evaporative diesel spray and an usefulness of a general-purpose program, ANSYS CFX release 11.0, are investigated through the comparison and investigation of the experimental results carried out under an evaporative field, in which there is phase transition, by an exciplex fluorescence method and the results analyzed by the CFX program. The diesel fuel called n-Tridecane, $C_{13}H_{28}$, is injected from a single-hole nozzle (l/d=1.0mm/0.2mm) into a constant volume chamber under a high temperature and pressure. In the same condition as the experimental condition, the analysis was carried out. Both results of the spray tip penetration were almost coincident at each time. The results have validated the usefulness of this analysis. As a result, if the ambient pressure is high, the spray tip penetration will be shortened and move toward the nozzle exit.