Characteristic Variations of H2O2 Concentrations Observed in Seoul (서울시 대기 중 과산화수소 농도 변화 특성)

  • Kim, Joo-Ae;Lee, Mee-Hye;Kim, Yung-Mi
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.3
    • /
    • pp.297-307
    • /
    • 2006
  • During January $2002{\sim}April\;2004$, hydrogen peroxide ($H_{2}O_{2}$) measurements were performed at the campus of Korea University, which is located in the northeastern part of Seoul. Gas phase hydroperoxide was collected in aqueous solution and separated by HPLC. Concentrations were determined by fluorescence using postcolumn enzyme derivatization. This measurement system was improved to be run automatically from sample collection at every 10 minutes through chemical analysis for data collection. Detection limits of $H_{2}O_{2}$ is $10{\sim}17\;pptv$, and the overall uncertainty of the measurements is better than 8%. Two-year measurements of $H_{2}O_{2}$ show typical seasonal variations. Concentrations of $H_{2}O_{2}$ were higher during $June{\sim}October$ and lower during $January{\sim}February$. Maximum concentration of 1-hour averaged $H_{2}O_{2}$ was 6.5 ppbv, which was observed in August and September. In general $H_{2}O_{2}$ concentrations were well correlated with $O_{3}$ concentrations and largely affected by meteorological factors such as temperature and wind direction.

A Study of Combustion Instability Mode in Dual Swirl Gas Turbine Combustor by PLIF and Chemiluminescence Measurement (PLIF 및 자발광 계측을 이용한 이중선회 가스터빈 연소기에서 연소불안정 모드 연구)

  • Choi, Inchan;Lee, Keeman;Juddoo, Mrinal;Masri, A.R.
    • Journal of the Korean Society of Combustion
    • /
    • v.19 no.1
    • /
    • pp.29-38
    • /
    • 2014
  • This paper described an experimental investigations of combustion instability mode in a lean premixed dual swirl combustor for micro-gasturbine system. When such the instability occurs, a strong coupling between pressure oscillations and unsteady heat release excites a self-sustained acoustic wave which results in a loud, annoyed sound and may also lead a structural damage to the combustion chamber. The detailed period of flame behavior and heat release in combustion instability mode have been examined with high speed OH and CH-PLIF system and $CH^*$ chemiluminescence measurement, flame tomography with operated at 10 kHz and 6 kHz each. Experiment results suggest that unstable flame behavior has a specific frequency with 200 Hz and this frequency is accords with about 1/2 sub-harmonic of combustor resonance frequency, not fundamental frequency. This is very interesting phenomenon that have not reported yet from other previous works. Therefore, when a thermo-acoustic instability with Rayleigh criterion occurs, the fact that the period of heat release and flame behavior are different each other was proposed for the first time through this work.

Analyses of Synchronous Fluorescence Spectra of Dissolved Organic Matter for Tracing Upstream Pollution Sources in Rivers (상류 오염원 추적을 위한 용존 유기물질 Synchronous 형광스펙트럼 분석 연구)

  • Hur, Jin;Kim, Mi-Kyoung;Park, Sung-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.317-324
    • /
    • 2007
  • Fluorescence measurements of dissolved organic matter(DOM) have the superior advantages over other analysis tools for applying to water quality management. A preliminary study was conducted to test the feasibility of applying synchronous fluorescence measurements for tracing and monitoring pollution sources in a small stream located in an upstream area of the Sooyoung watershed in Busan. The water quality of the small stream is affected by leachate from sawdust pile and discharge of untreated sewage. The sampling sites included an upstream site, two pipes discharging untreated sewage, leachate from sawdust, and a downstream site. Of the five field samples, the leachate was distinguished from the other samples by a high peak at a lower wavelength range and a blunt peak at 350nm, suggesting that synchronous fluorescence can be used as a discrimination tool for monitoring the pollution. The efficacy of various indices derived from the spectral features to discriminate the pollution source was tested for well-defined mixture of the sawdust leachate and the upstream stream by comparing (1)the difference between measured values and those predicted based on mass balance and the characteristics of the two samples and (2)the linear correlations between index values and mass ratios of the sample mixtures. Of various discrimination indices selected, fluorescence intensities at 276 nm$({\Delta}\lambda=30nm)$and 347 nm$({\Delta}\lambda=60nm)$ were suggested as promising potential discrimination indices for the sawdust pollution source. Despite the limited number of samples and the study area, this study illustrates the evaluation process that should be followed to develop rapid, low-cost discrimination indices to monitor pollution sources based on end member mixing analyses.

Simultaneous Measurements of CH-OH PLIF and Stereoscopic PIV in Turbulent Premixed Flames (CH-OH PLIF와 Stereoscopic PIV동시계측에 의한 난류예혼합화염의 관찰)

  • Choi, Gyung-Min;Tanahashi, Mamoru;Miyauchi, Toshio
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.91-96
    • /
    • 2004
  • Simultaneous CH and OH planar laser induced fluorescence(PLIF) and stereoscopic particle image velocimetry (PIV) measurements have been developed to investigate the local flame structure of turbulent premixed flames. The developed simultaneous two radical concentrations and three component velocity measurements on a two-dimensional plane was applied for relatively high Reynolds number turbulent premixed flames in a swirl stabilized combustor. All measurements were conducted for methane-air premixed flames in the corrugated flamelets regime. Strong three-dimensional fluctuation implies that misunderstanding of the flame/turbulent interactions would be caused by the analysis of two-component velocity distribution in a cross section. Furthermore, comparisons of CH-OH PLIF and three-component velocity field show that the burned gases not always have high-speed velocity in relatively high Reynolds number turbulent premixed flame. The Reynolds number dependence of the flame front was clearly captured by the simultaneous CH-OH PLIF and stereoscopic PIV measurements.

  • PDF

Graphene Oxide-based Direct Measurement of DNase I Activity with Single Stranded DNA

  • Gang, Jongback
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.9
    • /
    • pp.2749-2752
    • /
    • 2014
  • Recent studies have shown that single-stranded DNA adsorbed onto graphene oxide is protected from DNase I cleavage. However, double-stranded DNA bound to graphene oxide and could be digested by DNase I. To elucidate whether single-stranded DNA is protect from DNase I in the presence of graphene oxide, this study conducted DNase I digestion using single-stranded DNA and single-stranded DNA containing the duplex region in the presence of graphene oxide. Addition of DNase I resulted in restoration of the fluorescence emission that had been quenched when DNA was adsorbed to graphene oxide. It indicates that DNase I cleaved the adsorbed single-stranded DNA onto graphene oxide, which was sufficient for the detection of DNase I activity.

Confocal laser scanning microscopy image를 이용한 UASB granule의 메탄 생성 능력 측정

  • Lee, Yu-Jin;Kim, Hyo-Seop;An, Yeong-Hui;Park, Seong-Hun
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.365-369
    • /
    • 2000
  • Methanogenic activity of granular sludge was monitored by specific methanogenic activity (SMA) assay and confocal laser scanning microscopy (CLSM) during start-up of a thermophilic UASB reactor. Autofluorescence by CLSM could visualize the methanogenic bacterial population inside sludge granules and its intensity was proportional to SMA. Considering the complex procedures of SMA measurement, fluorescence quantification by CLSM can be suggested as a routine technique measuring methanogenic activity in UASB granules.

  • PDF

Heat Transfer Characteristics of Inclined Jet Impinging on a Pin Fin Heat Sink (경사진 충돌제트를 이용한 핀 휜 히트싱크의 열특성 연구)

  • Hong, Ki-Ho;Song, Tae-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.8 s.227
    • /
    • pp.961-967
    • /
    • 2004
  • An inclined jet impinging on a pin fin heat sink is proposed and investigated experimentally. To investigate the flow pattern, flow visualization using fluorescence and velocity measurement using particle image velocimetry(PIV) are conducted with water. The jet impinges over a wide span of the heat sink with a large recirculation in the upper free space and occasionally with another smaller one in the upstream corner. Further, thermal experimentation is conducted using air to obtain temperature profiles using a thermocouple rake in the air and using thermal image on the heat sink back plate, with impinging angles of 35, 45 and 55 degrees. The Reynolds number range based on the nozzle slot is varied from 1507 to 6405. The results show that impinging angle of 55 degree shows the largest heat transfer capability. The results of thermal experiment are compared and discussed with those of flow visualization.

A Study on Measurement of NO Concentrations in Laminar Nonpremixed $H_2/N_2$ Flame by LIF (레이저 유도 형광법(LIF)을 이용한 층류 비예혼합 $H_2/N_2$화염에서의 NO 농도측정에 관한 연구)

  • Kim, Sun-Wook;Jin, Seong-Ho;Kim, Gyung-Soo;Park, Kyoung-Suk
    • 한국연소학회:학술대회논문집
    • /
    • 2001.06a
    • /
    • pp.133-138
    • /
    • 2001
  • In this study, quantitative nitric oxide concentration distributions are investigated in the laminar nonpremixed $H_2/N_2$ flames by laser-induced fluorescence (LIF). The measurements are taken in flames for different $N_2$ dilution ratios varying from 20${\sim}$80%, and fuel now rate is fixed as lslpm. The NO A-X (0,0) vibrational band around 226 nm is excited using a XeCl excimer-pumped dye laser. We applied same excitation line used in $CH_4$ premixed flame. Overall, NO concentration was rapidly decreased with $N_2$ addition and we could not measure the concentration any longer for $N_2$ dilution above 80%.

  • PDF

Development of High-Intergrated DNA Chip Microarrays by Using Hydrophobic Interaction (소수성 상호작용을 이용한 고집적 DNA칩 마이크로어레이의 개발)

  • 김도균;최용성;권영수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.757-760
    • /
    • 2001
  • We have used the random fluidic self-assembly (RFSA) technique based on the chip pattern of hydrophobic self-assembly layers to assemble microfabricated particles onto the chip pattern. Immobilization of DNA, fabrication of the particles and the chip pattern, arrangement of the particles on the chip pattern, and recognition of each using DNA fluorescence measurement were carried out. Establishing the walls, the arrangement stability of the particles was improved. Each DNA is able to distinguish by using the lithography process on the particles. Advantages of this method are process simplicity, wide applicability and stability. It is thought that this method can be applicable as a new fabrication technology to develop a minute integration type biosensor microarray.

  • PDF

Simultaneous Measurement of Velocity and Concentration Field in a Stirred Mixer Using PIV/LIF Technique (PIV/LIF기법에 의한 교반혼합기 내의 속도장과 농도장 동시 측정)

  • Jeong, Eun-Ho;Yoon, Sang-Youl;Kim, Kyung-Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.4
    • /
    • pp.504-510
    • /
    • 2003
  • Simultaneous measurements of turbulent velocity and concentration field in a stirred mixer tank are carried out by using PIV/LIF technique. Instantaneous velocity fields are measured with a 1K$\times$1K CCD camera adopting the frame straddle method while the concentration fields are obtained by measuring the fluorescence intensity of Rhodamine B tracer excited by the second pulse of Nd:Yag laser light. Image distortion due to the camera view-angle is compensated by a mapping function. It is found that the general features of the mixing pattern are quite dependent on the local flow characteristics during the rapid decay of mean concentration. However, the small scale mixing seems to be independent on the local turbulent velocity fluctuation.