• 제목/요약/키워드: Fluorescence detection system

검색결과 133건 처리시간 0.024초

국산 Fluorescence in Situ Hybridization 시스템을 이용한 다양한 검체에서의 염색체 분석 (Chromosome Analysis in Clinical Samples by Chromosome Diagnostic System Using Fluorescence in Situ Hybridization)

  • 문신용;방명걸;오선경;류범용;황도영;정병준;최진;손철;장준근;김종원;김석현;최영민
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제24권3호
    • /
    • pp.335-340
    • /
    • 1997
  • Fluorescence in situ hybridization (FISH) techniques allow the enumeration of chromosome abnormalities and from a great potential for many clinical applications. In order to produce quantitative and reproducible results, expensive tools such as a cooled CCD camera and a computer software are required. We have developed a Chromosome Image Processing System (Chips) using FISH that allows the detection and mapping of the genetic aberrations. The aim of our study, therefore, is to evaluate the capabilities of our original system using a black-and-white video camera. As a model system, three repetitive DNA probes (D18Z1, DXZ1, and DYZ3) were hybridized to variety different clinical samples such as human metaphase spreads and interphase nuclei obtained from uncultured peripheral blood lymphocytes, uncultured amniocytes, and germ cells. The visualization of the FISH signals was performed using our system for image acquisition and pseudocoloring. FISH images were obtained by combining images from each of probes and DAPI counterstain captured separately. Using our original system, the aberrations of single or multiple chromosomes in a single hybridization experiment using chromosomes and interphase nuclei from a variety of cell types, including lymphocytes, amniocytes, sperm, and biopsied blastomeres, were enabled to evaluate. There were no differences in the image quality in accordance with FISH method, fluorochrome types, or different clinical samples. Always bright signals were detected using our system. Our system also yielded constant results. Our Chips would permit a level of performance of FISH analysis on metaphase chromosomes and interphase nuclei with unparalleled capabilities. Thus, it would be useful for clinical purposes.

  • PDF

Application of Engineered Zinc Finger Proteins Immobilized on Paramagnetic Beads for Multiplexed Detection of Pathogenic DNA

  • Shim, Jiyoung;Williams, Langley;Kim, Dohyun;Ko, Kisung;Kim, Moon-Soo
    • Journal of Microbiology and Biotechnology
    • /
    • 제31권9호
    • /
    • pp.1323-1329
    • /
    • 2021
  • Micro-scale magnetic beads are widely used for isolation of proteins, DNA, and cells, leading to the development of in vitro diagnostics. Efficient isolation of target biomolecules is one of the keys to developing a simple and rapid point-of-care diagnostic. A zinc finger protein (ZFP) is a double-stranded (ds) DNA-binding domain, providing a useful scaffold for direct reading of the sequence information. Here, we utilized two engineered ZFPs (Stx2-268 and SEB-435) to detect the Shiga toxin (stx2) gene and the staphylococcal enterotoxin B (seb) gene present in foodborne pathogens, Escherichia coli O157 and Staphylococcus aureus, respectively. Engineered ZFPs are immobilized on a paramagnetic bead as a detection platform to efficiently isolate the target dsDNA-ZFP bound complex. The small paramagnetic beads provide a high surface area to volume ratio, allowing more ZFPs to be immobilized on the beads, which leads to increased target DNA detection. The fluorescence signal was measured upon ZFP binding to fluorophore-labeled target dsDNA. In this study, our system provided a detection limit of ≤ 60 fmol and demonstrated high specificity with multiplexing capability, suggesting a potential for development into a simple and reliable diagnostic for detecting multiple pathogens without target amplification.

Photoluminescent Graphene Oxide Microarray for Multiplex Heavy Metal Ion Analysis

  • Liu, Fei;Ha, Hyun Dong;Han, Dong Ju;Park, Min Su;Seo, Tae Seok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.281.2-281.2
    • /
    • 2013
  • Since heavy metal ions included in water or food resources have critical effects on human health, highly sensitive, rapid and selective analysis for heavy metal detection has been extensively explored by means of electrochemical, optical and colorimetric methods. For example, quantum dots (QDs), such as semiconductor QDs, have received enormous attention due to extraordinary optical properties including high fluorescence intensity and its narrow emission peaks, and have been utilized for heavy metal ion detection. However, the semiconductor QDs have a drawback of serious toxicity derived from cadmium, lead and other lethal elements, thereby limiting its application in the environmental screening system. On the other hand, Graphene oxide (GO) has proven its superlative properties of biocompatibility, unique photoluminescence (PL), good quenching efficiency and facile surface modification. Recently, the size of GO was controlled to a few nanometers, enhancing its optical properties to be applied for biological or chemical sensors. Interestingly, the presence of various oxygenous functional groups of GO contributes to opening the band gap of graphene, resulting in a unique PL emission pattern, and the control of the sp2 domain in the sp3 matrix of GO can tune the PL intensity as well as the PL emission wavelength. Herein, we reported a photoluminescent GO array on which heavy metal ion-specific DNA aptamers were immobilized, and sensitive and multiplex heavy metal ion detection was performed utilizing fluorescence resonance energy transfer (FRET) between the photoluminescent monolayered GO and the captured metal ion.

  • PDF

Integrated Rotary Genetic Analysis Microsystem for Influenza A Virus Detection

  • Jung, Jae Hwan;Park, Byung Hyun;Choi, Seok Jin;Seo, Tae Seok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.88-89
    • /
    • 2013
  • A variety of influenza A viruses from animal hosts are continuously prevalent throughout the world which cause human epidemics resulting millions of human infections and enormous industrial and economic damages. Thus, early diagnosis of such pathogen is of paramount importance for biomedical examination and public healthcare screening. To approach this issue, here we propose a fully integrated Rotary genetic analysis system, called Rotary Genetic Analyzer, for on-site detection of influenza A viruses with high speed. The Rotary Genetic Analyzer is made up of four parts including a disposable microchip, a servo motor for precise and high rate spinning of the chip, thermal blocks for temperature control, and a miniaturized optical fluorescence detector as shown Fig. 1. A thermal block made from duralumin is integrated with a film heater at the bottom and a resistance temperature detector (RTD) in the middle. For the efficient performance of RT-PCR, three thermal blocks are placed on the Rotary stage and the temperature of each block is corresponded to the thermal cycling, namely $95^{\circ}C$ (denature), $58^{\circ}C$ (annealing), and $72^{\circ}C$ (extension). Rotary RT-PCR was performed to amplify the target gene which was monitored by an optical fluorescent detector above the extension block. A disposable microdevice (10 cm diameter) consists of a solid-phase extraction based sample pretreatment unit, bead chamber, and 4 ${\mu}L$ of the PCR chamber as shown Fig. 2. The microchip is fabricated using a patterned polycarbonate (PC) sheet with 1 mm thickness and a PC film with 130 ${\mu}m$ thickness, which layers are thermally bonded at $138^{\circ}C$ using acetone vapour. Silicatreated microglass beads with 150~212 ${\mu}L$ diameter are introduced into the sample pretreatment chambers and held in place by weir structure for construction of solid-phase extraction system. Fig. 3 shows strobed images of sequential loading of three samples. Three samples were loaded into the reservoir simultaneously (Fig. 3A), then the influenza A H3N2 viral RNA sample was loaded at 5000 RPM for 10 sec (Fig. 3B). Washing buffer was followed at 5000 RPM for 5 min (Fig. 3C), and angular frequency was decreased to 100 RPM for siphon priming of PCR cocktail to the channel as shown in Figure 3D. Finally the PCR cocktail was loaded to the bead chamber at 2000 RPM for 10 sec, and then RPM was increased up to 5000 RPM for 1 min to obtain the as much as PCR cocktail containing the RNA template (Fig. 3E). In this system, the wastes from RNA samples and washing buffer were transported to the waste chamber, which is fully filled to the chamber with precise optimization. Then, the PCR cocktail was able to transport to the PCR chamber. Fig. 3F shows the final image of the sample pretreatment. PCR cocktail containing RNA template is successfully isolated from waste. To detect the influenza A H3N2 virus, the purified RNA with PCR cocktail in the PCR chamber was amplified by using performed the RNA capture on the proposed microdevice. The fluorescence images were described in Figure 4A at the 0, 40 cycles. The fluorescence signal (40 cycle) was drastically increased confirming the influenza A H3N2 virus. The real-time profiles were successfully obtained using the optical fluorescence detector as shown in Figure 4B. The Rotary PCR and off-chip PCR were compared with same amount of influenza A H3N2 virus. The Ct value of Rotary PCR was smaller than the off-chip PCR without contamination. The whole process of the sample pretreatment and RT-PCR could be accomplished in 30 min on the fully integrated Rotary Genetic Analyzer system. We have demonstrated a fully integrated and portable Rotary Genetic Analyzer for detection of the gene expression of influenza A virus, which has 'Sample-in-answer-out' capability including sample pretreatment, rotary amplification, and optical detection. Target gene amplification was real-time monitored using the integrated Rotary Genetic Analyzer system.

  • PDF

Study on Bead-based Microbiochip and Analytical System for Protein Detection

  • Kim, Min-Soo;Chung, Woo-Jae;Cho, Su-Hyung;Park, Sung-Soo;Kim, Byung-Gee;Lee, Young-Sik;Kim, Yong-Kweon
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.60-63
    • /
    • 2002
  • This paper presents bead-based microbiocihps to detect and separate target proteins. Micro beads coated with capture proteins were introduced into a microchamber, and target proteins flowing across the chamber were bound and concentrated. The chip was connected with an external fluid system. Bead surfaces were double-coated with photo-cleavable linkers and capture proteins. The proteins bound on the beads were photo-separated under UV irradiation, and excited to be measured in fluorescence. $38{\sim}50{\mu}m$ sized polystyrene beads were used. SOGs(silicon-on-glass) were used to fabricate the microchip having glasses bonded on both sides. 100 ${\mu}m$ thick silicon channel was formed through silicon deep RIE process. The upper glass cover had holed through to have inlets and outlets fabricated by powder-blastings. In this study, biotin and streptavidin were used as capture proteins and detection proteins, respectively. The protein mixtures of streptavidin, HSA(human serum albumin) and ovalbumin were applied for selective detection test.

  • PDF

Establishment of a Stable Cell Line Expressing Green Fluorescence Protein-fused Hypoxia Inducible Factor-1α for Assessment of Carcinogenicity of Chemical Toxicants

  • Kim, Sung-Hye;Seo, Hee-Won;Lee, Min-Ho;Chung, Jin-Ho;Lee, Byung-Hoon;Lee, Mi-Ock
    • Toxicological Research
    • /
    • 제25권4호
    • /
    • pp.189-193
    • /
    • 2009
  • Hypoxia inducible factor $1\alpha$ (HIF-$1\alpha$) is a potential marker of carcicnogenesis since it is overexpresssed in many human cancers such as brain, breast, and uterus, and its role has implicated in tumor cell growth and metastasis. In this study, we established a stable cell line that express green fluorescence protein (GFP)-fused hypoxia inducible factor $1\alpha$ (HIF-$1\alpha$) and evaluated the potential use of this cell line for assessment of carcinogenicity of chemical toxicants. Western blot analysis as well as fluorescence measurements showed that protein-level of GFP-HIF-$1\alpha$ was significantly enhanced in a dose-dependent manner upon treatment of hypoxia mimicking agents such as dexferrioxamine and $CoCl_2$. Well-Known tumor promoters such as mitomycin and methyl methanesulfonate. significantly induced the fluorescence intensity of GFP-HIF-$1\alpha$, whereas the known negative controls such as o-anthranilic acid and benzethonium chloride, did not. These results indicate that HIF-$1\alpha$ could be a biological parameter for detection of tumor initiators/promoters and suggest that the GFP-HIF-$1\alpha$ cell line is a useful system for screening of carcinogenic toxicants.

유류 오염 토양에서의 단일방향족 탄화수소 농도 측정을 위한 자외선 형광 분석에 관한 연구 (Detection of fluorescence from soils contaminated with monoaromatic hydrocarbons)

  • 김우진;박재우;이주인
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제7권2호
    • /
    • pp.35-44
    • /
    • 2002
  • 유류로 오염될 위험성이 있는 지역에서 유류의 누출을 미리 감지하여 오염의 확산을 막기 위한 시스템을 개발하기 위하여, 유류에 상당량이 함유되어 있는 벤젠, 톨루엔, 에틸벤젠, 자일렌의 농도별 형광세기를 측정하였다. 이것은 단일방향족 탄화수소계 물질이 260nm대의 자외선영역의 빛을 흡수하여 290nm 파장 영역의 형광을 낸다는 원리를 이용한 것이었으나 실제 토양 시료의 형광을 측정할 때는 300-600nm파장 영역에서 형광이 나왔다 이것은 토양이 입자 물질로 구성되어 있기 때문에 나타나는 경향이라 사료된다. 흡광 영역이 비슷한 이 네 가지 단일 방향족 탄화수소계 물질들은 그 형광을 내는 파장 영역도 비슷하였으며, 토양시료의 형광세기는 오염시킨 농도가 증가함에 따라 증가하였다. 또한 이러한 경향은 토양 입자가 미세한 토양에서 더 뚜렷하게 나타났다. 따라서 본 측정 기술은 기존의 방법에 비하여 신뢰도가 높은 데이터를 얻을 수 있고, 간편하고 단순하여 한번의 설치로 주기적인 측정이 가능하므로 유류 오염의 위험이 있는 지역에서의 상시 측정장치로서 효과적일 것으로 판단된다.

광학형광법에 의한 란탄족 원소의 정밀분석법에 관한 연구 일부 : TTA, n-Octanol 과 Triton X-100 의 삼성분 착물계에 의한 희토류 원소의 형광분석 방법 (Precision Analysis of Lanthanides by Fluorescence Spectroscopy Part one : Flourimetric Determination of Rare Earths by Ternary Complexes of TTA, n-Octanol and Triton X-100)

  • 차기원;박광원;하영구;김하석
    • 대한화학회지
    • /
    • 제38권9호
    • /
    • pp.653-659
    • /
    • 1994
  • pH 7인 수용액에서 2-thenoyltrifluoroacetone(TTA), n-octanol과 Triton X-100의 존재하에서 유로퓸과 사마륨의 형광세기가 크게 증가하였다. 또한 이 착물에 과량의 $La^{3+}$을 첨가할 때 형광세기가 100배 이상 증가하였다. 유로퓸과 사마륨의 최대 들뜨기 파장은 각각 345 nm과 380 nm이고, 최대 형광파장은 각각 617 nm, 567 nm 이었다. 유로퓸과 사마륨의 형광세기는 농도가 각각 $1{\times}10^{-7}∼1{\tiems}10^{-9}\;M,\;1{\tiems}10^{-5}∼1{\times}10^{-7}\;M$에서 직선적으로 증가하였고, 유로퓸은 $1{\times}10^{-11}\;M$ 그리고 사마륨은 $1{\times}10^{-8}\;M$까지 검출할 수 있었다.

  • PDF

Development of a multi-modal imaging system for single-gamma and fluorescence fusion images

  • Young Been Han;Seong Jong Hong;Ho-Young Lee;Seong Hyun Song
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3844-3853
    • /
    • 2023
  • Although radiation and chemotherapy methods for cancer therapy have advanced significantly, surgical resection is still recommended for most cancers. Therefore, intraoperative imaging studies have emerged as a surgical tool for identifying tumor margins. Intraoperative imaging has been examined using conventional imaging devices, such as optical near-infrared probes, gamma probes, and ultrasound devices. However, each modality has its limitations, such as depth penetration and spatial resolution. To overcome these limitations, hybrid imaging modalities and tracer studies are being developed. In a previous study, a multi-modal laparoscope with silicon photo-multiplier (SiPM)-based gamma detection acquired a 1 s interval gamma image. However, improvements in the near-infrared fluorophore (NIRF) signal intensity and gamma image central defects are needed to further evaluate the usefulness of multi-modal systems. In this study, an attempt was made to change the NIRF image acquisition method and the SiPM-based gamma detector to improve the source detection ability and reduce the image acquisition time. The performance of the multi-modal system using a complementary metal oxide semiconductor and modified SiPM gamma detector was evaluated in a phantom test. In future studies, a multi-modal system will be further optimized for pilot preclinical studies.

Detection and Quantification of Toxin-Producing Microcystis aeruginosa Strain in Water by NanoGene Assay

  • Lee, Eun-Hee;Cho, Kyung-Suk;Son, Ahjeong
    • Journal of Microbiology and Biotechnology
    • /
    • 제27권4호
    • /
    • pp.808-815
    • /
    • 2017
  • We demonstrated the quantitative detection of a toxin-producing Microcystis aeruginosa (M. aeruginosa) strain with the laboratory protocol of the NanoGene assay. The NanoGene assay was selected because its laboratory protocol is in the process of being transplanted into a portable system. The mcyD gene of M. aeruginosa was targeted and, as expected, its corresponding fluorescence signal was linearly proportional to the mcyD gene copy number. The sensitivity of the NanoGene assay for this purpose was validated using both dsDNA mcyD gene amplicons and genomic DNAs (gDNA). The limit of detection was determined to be 38 mcyD gene copies per reaction and 9 algal cells/ml water. The specificity of the assay was also demonstrated by the addition of gDNA extracted from environmental algae into the hybridization reaction. Detection of M. aeruginosa was performed in the environmental samples with environmentally relevant sensitivity (${\sim}10^5$ algal cells/ml) and specificity. As expected, M. aeruginosa were not detected in nonspecific environmental algal gDNA over the range of $2{\times}10^0$ to $2{\times}10^7$ algal cells/ml.