• Title/Summary/Keyword: Fluorescence detection system

Search Result 133, Processing Time 0.026 seconds

Optimal Optical Filters of Fluorescence Excitation and Emission for Poultry Fecal Detection

  • Kim, Tae-Min;Lee, Hoon-Soo;Kim, Moon-S.;Lee, Wang-Hee;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • v.37 no.4
    • /
    • pp.265-270
    • /
    • 2012
  • Purpose: An analytic method to design excitation and emission filters of a multispectral fluorescence imaging system is proposed and was demonstrated in an application to poultry fecal inspection Methods: A mathematical model of a multispectral imaging system is proposed and its system parameters, such as excitation and emission filters, were optimally determined by linear discriminant analysis (LDA). An alternating scheme was proposed for numerical implementation. Fluorescence characteristics of organic materials and feces of poultry carcasses are analyzed by LDA to design the optimal excitation and emission filters for poultry fecal inspection. Results: The most appropriate excitation filter was UV-A (about 360 nm) and blue light source (about 460 nm) and band-pass filter was 660-670 nm. The classification accuracy and false positive are 98.4% and 2.5%, respectively. Conclusions: The proposed method is applicable to other agricultural products which are distinguishable by their spectral properties.

COMPARATIVE STUDY ON THE EARLY DETECTION OF ENAMEL LESIONS USING DIFOTI AND LASER FLUORESCENCE (Digital Imaging Fiber-Optic Trans-Illumination과 Laser Fluorescence를 이용한 법랑질 우식증의 조기 진단에 관한 비교 연구)

  • Maeng, Myoung-Ho;Kim, Seung-Oh;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.207-220
    • /
    • 2006
  • The newly developed equipments for the early detection of carious lesion are LFD (laser fluorescence device), Ultrasonic diagnostic system, CLSM(confocal laser scanning microscopy), QLF(quantitative light-induced fluorescence) and DIFOTI (digital imaging fiber-optic trans-illumination) system. In this study, DIFOTI system and LFD were used for the detection of early enamel caries. Twenty five primary teeth extracted from twenty one children at around the dentitional exchanging period were selected as samples. The results obtained from DIFOTI imaging and LFD measurement were compared with those of CLSM and comprehensive evaluations were made for the diagnostic capacity of each device. In vitro test, 40 sample teeth with their buccal & lingual surface formed by a window of $2{\times}3mm$ in diameter were immersed in artificial demineralizing solution for the period of 4, 8, 12 and 16 days. The results obtained from the experimental groups (DIFOTI, LFD) were compared to control group (CLSM) and we have reached to the following conclusions. 1. The sensitivity and specificity of DIFOTI system operated in oral environment was 88.2% and 76.9% respectively. 2. The sensitivity and specificity of LFD measured in oral environment was 76.5% and 69.2% respectively. 3, Regression analysis on the light transparent rate of DIFOTI showed its decrease according to the length of primary enamel decalcification performed in vitro(r=-0.96, p<0.05). 4. No statistically significant difference between LFT measurement and the length of in vitro decalcification was found in regression analysis (p>0.05). 5. The correlation coefficient of DIFOTI image transparent rate and the lesion depth of CLMS was -0.6988 (p<0.05), whereas no statistically significant difference was found for LFD measurement.

  • PDF

Label/Quencher-Free Detection of Exon Deletion Mutation in Epidermal Growth Factor Receptor Gene Using G-Quadruplex-Inducing DNA Probe

  • Kim, Hyo Ryoung;Lee, Il Joon;Kim, Dong-Eun
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.1
    • /
    • pp.72-76
    • /
    • 2017
  • Detection of exon 19 deletion mutation in the epidermal growth factor receptor (EGFR) gene, which results in increased and sustained phosphorylation of EGFR, is important for diagnosis and treatment guidelines in non-small-cell lung cancer. Here, we have developed a simple and convenient detection system using the interaction between G-quadruplex and fluorophore thioflavin T (ThT) for discriminating EGFR exon 19 deletion mutant DNA from wild type without a label and quencher. In the presence of exon 19 deletion mutant DNA, the probe DNAs annealed to the target sequences were transformed into G-quadruplex structure. Subsequent intercalation of ThT into the G-quadruplex resulted in a light-up fluorescence signal, which reflects the amount of mutant DNA. Due to stark differences in fluorescence intensity between mutant and wild-type DNA, we suggest that the induced G-quadruplex structure in the probe DNA can report the presence of cancer-causing deletion mutant DNAs with high sensitivity.

Turn-On Type Fluorogenic and Chromogenic Probe for the Detection of Trace Amount of Nitrite Ion in Water

  • Saleem, Muhammad;Abdullah, Razack;Hong, In Seok;Lee, Ki-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.2
    • /
    • pp.389-393
    • /
    • 2013
  • A rhodamine B-based fluorescent probe for nitrite ion ($NO{_2}^-$) has been designed, synthesized, characterized and its properties for recognition of $NO{_2}^-$ were studied. Nearly non fluorescent probe upon reaction with nitrite ion significantly triggered the fluorescence. Fluorescence response is based on ring opening of the spirolactam of rhodamine B phenyl hydrazide showing maximum absorbance at 552 nm and maximum emission at 584 nm. Probe 3 exhibited high sensitivity and extreme selectivity for nitrite ion over other common ions and oxidants ($Cl^-$, $ClO^-$, $ClO{_2}^-$, $ClO{_3}^-$, $ClO{_4}^-$, $SO{_4}^{2-}$, $SiO{_3}^{2-}$, $NO{_3}^{2-}$, $CO{_3}^{2-}$) examined in methanol water (1:1, v/v) at pH 7.0. The probe might be a new efficient tool for detection of nitrite ion in natural water and biological system.

Application of Quantum-dot Nanocrystals for Cyanobacterial Toxin-Microcystin Detection (나노크리스탈 Quantum-dot을 적용한 남조류 독소 Microcystin 탐지 연구)

  • Lee, Jinwook;Yu, Hye-Weon;Kim, In S.
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.705-711
    • /
    • 2007
  • Green quantum-dot nanocrystal (QD525) with anti-microcystin monoclonal antibody was applied for detection of microcystin, a monocyclic peptide hepatotoxin, extracted from the culture of Microcystis aeruginosa. The presence of microcystin in the cell lysate was verified by HPLC analysis with UV absorbance at 238 nm. Microcystis cell extract exhibited fluorescence emission spectra, which peak was around 460 nm because of their complex organic substances. When a spherical QD525 antibody conjugates (10~20 nm in diameter) were bound to the microcystins in the Microcystis cell lysate, the fluorescence intensity of the primary peak at 525 nm diminished while the secondary emission peak at 460 nm slightly increased intensities. It is due to energy transfer from the primary (major) to the secondary (minor) peak, resulting from physical deformation of QD525 and different environmental factors. On the other hand, other cell extracts did not show any fluorescence emission change. This study is very available for detecting and monitoring the microcystin because it is one step assay without washing step and portable spectrophotometer makes on-site measurement possible. For health risk assessment of the microcystin, the reliable and rapid system to detect and quantify microcystin is seriously required.

Spectrofluorimetric Determination of Sparfloxacin Using Europium(III) as a Fluorescence Probe in Micellar Medium

  • Kamruzzaman, Mohammad;Alam, Al-Mahmnur;Lee, Sang-Hak;Kim, Young-Ho;Kim, Sung-Hong;Kim, Gyu-Man
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.1
    • /
    • pp.105-110
    • /
    • 2012
  • A europium (III)-sensitized, spectrofluorimetric (FL) method is presented for the determination of sparfloxacin (SPAR) using an anionic surfactant, sodium dodecyl benzene sulphonate (SDBS). The method is based on the strong fluorescence (FL) enhancement of SPAR after the addition of $Eu^{3+}$ ions as fluorescence probes. The experimental results indicated that the FL intensity of the SPAR-$Eu^{3+}$ system was enhanced markedly by SDBS. The maximum FL emission signal was obtained at about 615 nm when excited at 372 nm. The experimental conditions that affected the FL intensity of the SPAR-$Eu^{3+}$-SDBS system were optimized systematically. The enhanced FL intensity of the system exhibited a good linear relationship with the SPAR concentration over the range of $1.5{\times}10^{-9}-1.2{\times}10^{-7}mol\;L^{-1}$ with a correlation coefficient (r) of 0.9987. The limit of detection ($3{\delta}$) was $4.15{\times}10^{-10}mol\;L^{-1}$ with a relative standard deviation (RSD) of 1.65%. This method was successfully applied for the determination of SPAR in pharmaceuticals, and human serum and urine samples with higher sensitivity, wide dynamic range and better stability. The possible interaction mechanism of the system is also discussed in detail by ultraviolet absorption spectra and FL spectra.

Microprocessor Based Laser Induced Fluorometry I. Development of System and Application to Liquid Chromatography

  • Kim, Ha-Suck;Park, Chan-Seung;Hwang, Eui-Jin;Chol, Q.-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.5 no.6
    • /
    • pp.253-259
    • /
    • 1984
  • An analytical applicability of the fluorescence detection with an optical multichannel analyzer to organic dyes was studied in this work. Continuous acquisition of spectra was possible with the use of a microcomputer. The maximum acquisition rate of a spetrum with 70-point average was about 3 seconds. Floppy discs were used to store data for later use in processing. Laser induced fluorescence detector in High Performance Liquid Chromatography was chosen for an application. Fluorescein below $10^{-15}g$ was detected satisfactorily using this system. With the help of microcomputer, three dimensional chromatograms of time-wavelength-intensity were obtained.

Improvement of detection sensitivity of impurities on Si wafer surface using synchrotron radiation (방사광을 이용한 Si 웨이퍼 표면불순물 검출감도 향상)

  • 김흥락;김광일;강성건;김동수;윤화식;류근걸;김영주
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.1
    • /
    • pp.13-19
    • /
    • 1999
  • Total reflection X-ray fluorescence spectroscopy using synchrotron radiation source called as TRSFA was explored to achieve high sensitivities to impurity metals on Si wafer surface. It consists of monochromating part to select a specific wavelength, slit part to shield direct beam and to control monochromated beam, and main chamber to dectect fluorescent X-ray counts of impurities on si wafer. Monochromated X-ray of 10.90 KeV was selected and the optimum total reflection condition on silicon wafer was obtained through tuning the dead time and fluorescent X-ray count of Si and Fe. TRSFA system could increase the sensitivity as high as 50 times in comparision with TRXFA using normal X-ray source. But the trend was varied since the surface conditions of Si wafers and, therefore, the reflectivities were different. Furthemore, there seems to be a promising path to reaching a detection limit useful to the next generation metal impurities control, because Fe impurity below to the $5\times10^{9}\textrm{atomas/cm}^2$ can be detectable through the developed TRSFA system.

  • PDF

Salicylimine-Based Colorimetric and Fluorescent Chemosensor for Selective Detection of Cyanide in Aqueous Buffer

  • Noh, Jin Young;Hwang, In Hong;Kim, Hyun;Song, Eun Joo;Kim, Kyung Beom;Kim, Cheal
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.7
    • /
    • pp.1985-1989
    • /
    • 2013
  • A simple colorimetric and fluorescent anion sensor 1 based on salicylimine showed a high selectivity and sensitivity for detection of cyanide in aqueous solution. The receptor 1 showed high selectivity toward $CN^-$ ions in a 1:1 stoichiometric manner, which induces a fast color change from colorless to orange and a dramatic enhancement in fluorescence intensity selectively for cyanide anions over other anions. Such selectivity resulted from the nucleophilic addition of $CN^-$ to the carbon atom of an electron-deficient imine group. The sensitivity of the fluorescence-based assay (0.06 ${\mu}M$) is below the 1.9 ${\mu}M$ suggested by the World Health Organization (WHO) as the maximum allowable cyanide concentration in drinking water, capable of being a practical system for the monitoring of $CN^-$ concentrations in aqueous samples.