• Title/Summary/Keyword: Fluorescence Materials

Search Result 508, Processing Time 0.025 seconds

Analysis of yttrium and scandium content in industrial phosphoric acid using wavelength dispersive X-ray fluorescence spectrometry (WDXRF)

  • Mohamed Guitouni
    • Analytical Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.315-327
    • /
    • 2024
  • The wavelength-dispersive X-ray fluorescence spectrometry (WDXRF) method for determining yttrium and scandium in industrial phosphoric acid passes all validation tests and can be used for these elements. The proposed method's procedure is simple, fast and does not require reagents for preparation and with low operating costs. The yttrium and scandium concentrations in Tunisian phosphoric acid are in the order of 60 ppm for yttrium with a coefficient of variation of 1.09 % and about 15 ppm for scandium with a coefficient of variation of 1.33 %.

Fluorescence Behavior of Benzo[f]Quinoline Doped In Lpd Silica Thin Films

  • Mabuchi, Toshiaki;Suzuki, Satoshi;Nakajima, Tsuyoshi;Ino, Juichi;Takemura, Kazuo;Shimizu, Etsuro
    • Journal of Photoscience
    • /
    • v.5 no.3
    • /
    • pp.105-109
    • /
    • 1998
  • By using the liquid -phase-deposition (LPD) process, which has a potetnial of preparing organic inorganic composite materials, samples doped with benzo[f]quinoline (BfQ)into silica thia films wre prepared. We observed the fluorescene and fluorescene excitation spectra of the samples, as well as the fluorescence lifetimes and time-resoluved fluorescence spectra. The comparison of thefluorescence spectra in pH-controlled buffer solutions yields the results that the dominant species of BfQ in the LPD silica films is a protonated one. The fluorescence band assigned to a hydrogen-bonded species was observed on the samples prepared from the dipping solutions of 3 and 2 M hexafluorosilicic acid. The band assignment was confirmed by the fluorescence lifetime measurement. The FT-IR M hexaflurosilicic acid. The band assignment was confirmed by the flurescence lifetime meausurement. The FT-IR data proved the existence of included water in silica films prepared from the LPD process. The appearance of the band corresponding to the hydrogen-bonded species within LPD silica phases was explained by the proesence of included water. Depending on the preparation conditions of LPD silica films, the band assigned to protonated species shows bad shifts in a wavenumber region between the peak of hydrogen-bonded and typical protonated species. This implies that there is some distribution of steric conformation of protonated species of BfQ interacting with adsorbing sites of LPD silica. The time -resolved fluorescence spectra suggest that some relaxation process is involved in the conformation of BfQ doped into the solid phase of LPD silica.

  • PDF

Using Hyperspectral Fluorescence Spectra of Deli Commodities to Select Wavelengths for Surveying Deli Food Contact Surfaces

  • Lefcourt, Alan M.;Beck, Elizabeth A.;Lo, Y. Martin;Kim, Moon S.
    • Journal of Biosystems Engineering
    • /
    • v.40 no.2
    • /
    • pp.145-152
    • /
    • 2015
  • Purpose: The inability to adequately judge the efficacy of cleaning and sanitation procedures in deli departments is a recognized food safety concern. In a prior study, our research group demonstrated that visual inspection of cleaned produce processing surfaces could be enhanced through the use of a portable fluorescence imaging device that detected residual produce residues. Methods: To explore the feasibility of using fluorescence imaging to similarly detect residual deli residues, spectra of American, Cheddar, Provolone, and Swiss cheeses and of processed chicken, ham, roast beef, and turkey were acquired using a laboratory hyperspectral imaging system. Circular punches of these commodities were placed onto stainless steel and high density polyethylene coupons for imaging. The coupon materials were selected to represent common surfaces found in deli departments. Results: Analysis of hyperspectral fluorescence images showed that cheeses exhibited peaks in the blue-green region and at around 675 nm. Meats exhibited peaks in the blue-green region with one of four ham and one of four chicken brands exhibiting peaks at around 675 nm, presumably due to use of plant-derived additives. When commodities were intermittently imaged over two weeks, locations of spectral peaks were preserved while intensity of peaks at shorter wavelengths increased with time. Conclusion: These results demonstrate that fluorescence imaging techniques have the potential to enhance surface hygiene inspection in deli departments and, given the immediate availability of imaging results, to help optimize routine cleaning procedures.

Real-time Vessel Navigation Using Indocyanine Green Fluorescence during Robotic or Laparoscopic Gastrectomy for Gastric Cancer

  • Kim, Mina;Son, Sang-Yong;Cui, Long-Hai;Shin, Ho-Jung;Hur, Hoon;Han, Sang-Uk
    • Journal of Gastric Cancer
    • /
    • v.17 no.2
    • /
    • pp.145-153
    • /
    • 2017
  • Purpose: Identification of the infrapyloric artery (IPA) type is a key component of pylorus-preserving gastrectomy. As the indocyanine green (ICG) fluorescence technique is known to help visualize blood vessels and flow during reconstruction, we speculated that this emerging technique would be helpful in identifying the IPA type. Materials and Methods: From August 2015 to February 2016, 20 patients who underwent robotic or laparoscopic gastrectomy were prospectively enrolled. After intravenous injection of approximately 3 mL of ICG (2.5 mg/mL), a near-infrared fluorescence apparatus was applied. The identified shape of the IPA was confirmed by examining the actual anatomy following infrapyloric dissection. Results: The mean interval time between ICG injection and visualization of the artery was 22.2 seconds (range, 14-30 seconds), and the mean duration of the arterial phase was 16.1 seconds (range, 9-30 seconds). The overall positive predictive value (PPV) of ICG fluorescence in identifying the IPA type was 80% (16/20). The IPA type was incorrectly predicted in four patients, all of whom were obese with a body mass index (BMI) of more than $25kg/m^2$. Conclusions: Our preliminary results indicate that intraoperative vascular imaging using the ICG fluorescence technique may be helpful for robotic or laparoscopic pylorus-preserving gastrectomy.

Comparative Studies on Two Fluoro-Substituted 2-Pyrazoline Derivatives with Experimental and Theoretical Methods

  • Guo, Huan-Mei;Wang, Xian;Jian, Fang Fang;Xiao, Hai Lian;Zhao, Pu Su
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.5
    • /
    • pp.1061-1066
    • /
    • 2009
  • Two fluoro-substituted 2-pyrazoline derivatives, 1-phenyl-3-(4-methoxyphenyl)-5-(4-fluorophenyl)-2-pyrazoline (1) and 1-phenyl-3-(4-methoxyphenyl)-5-(2-fluoro-phenyl)-2-pyrazoline (2) have been synthesized and characterized by elemental analysis, IR, UV-Vis and fluorescence spectra. The crystal structure of 1 has been determined by X-ray single crystal diffraction. For the two compounds, density functional theory (DFT) calculations of the structures and natural population atomic charge analysis (NPA) have been performed at B3LYP/6-311G** level of theory. By using TD-DFT method, electron spectra of 1 and 2 have been predicted, which are very approximate with the experimental ones. Comparative studies on 1 and 2 indicate that the location change of fluorine atom in 5-position phenyl ring of 2-pyrazoline does not make significant change of geometries and electronic transition bands, but it leads to evident change of atomic charge distributions and peak intensities of UV and fluorescence spectra.

Photosystem I and II Reaction Centers in a New Type Oxygenic Photosynthesis of Acaryochloris marina Based on Chlorophyll d: Studies of Delayed Fluorescence and Triplet State ESR

  • Itoh, Shigeru;Fukushima, Yoshimasa;Itoh, Kunihiro;Maeda, Masanori;Mino, Hiroyuki;Kumazaki, Shigeichi
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.70-73
    • /
    • 2002
  • A cyanobacteria-like organism Aaryochloris marina performs oxygenic photosynthesis with near far-red light by the use of chlorophyll d. Reaction center chlorophyll (Chl) of Photosystem (PS) II of A. marina was studied by analysis of millisecond-delayed fluorescence. Delayed fluorescence is emitted by Chi d indicating efficient energy transfer between antenna Chi d molecules and the unknown primary electron donor of PS II. P740 a reaction center Chl of PS I of A. marina is shown to give a dimer type cation, and triplet state with a D value of 245xlO$\^$-4/ cm$\^$-l/ in contrast to the 280-290 xlO$\^$-4/cm$\^$-l/ values of P700 suggesting triplet spins interacting at a 5% larger distance in P740 than in P700.

  • PDF

Polarity Probing Two-Photon Fluorophores Based on [2.2]Paracyclophane

  • Woo, Han-Young;Korystov, Dmitry;Jin, Young-Eup;Suh, Hong-Suk
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.12
    • /
    • pp.2253-2260
    • /
    • 2007
  • A series of tetra donor substituted [2.2]paracyclophane-based two-photon absorption (TPA) fluorophores were synthesized in neutral and cationic forms. The imaging activity of overall set of fluorophores was studied by the two-photon induced fluorescence (TPIF) method in a range of solvents. We also measured a clear progression toward a longer photoluminescence lifetime with increasing solvent polarity (intrinsic photoluminescence lifetime, τi: ~2 ns in toluene → 12-16 ns in water). The paracyclophane fluorophores with this unique property can be utilized as an optical polarity probe for the biomolecular substrates. The combined measurement of the two-photon fluorescence microscopy (TPM) cell image and TPIF lifetime can give us a better understanding of the biological processes and local environments in the cells.

Ultrahigh Efficiency from Novel Blue Emitters Using a Rational Molecular Design

  • Kim, Soo-Kang;Park, Young-Il;Park, Jong-Wook
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.921-924
    • /
    • 2008
  • We investigated new deep blue emitting materials including a novel side group such as CB-203. CB-203 shows relatively 40% increased PL quantum efficiency and higher Tg of $30^{\circ}C$ compared to MADN. It exhibits high External Quantum Efficiency (EQE) of 7.18% that is two times bigger than MADN's, which is the best efficiency in case of non-doped blue fluorescence OLED device to our knowledge. And deep blue emitting materials with a new core structure (CB-301) have been synthesized. CB-301 exhibit excellent blue fluorescence properties. Undoped OLED devices using CB-301 as blue emitters was found to deep blue CIE value (0.154, 0.078) and exhibit high luminance efficiencies of 2.01cd/A at $10\;mA/cm^2$.

  • PDF