• Title/Summary/Keyword: Fluidized-bed

Search Result 768, Processing Time 0.035 seconds

The Heat Transfer Performance with Pumping Power for a Particle Bed Heat Exchanger (입자층(粒子層)을 이용한 열교환기(熱交換器)에서 소요동력(所要動力)에 따른 전열특성(傳熱特性)에 관(關)한 연구(硏究))

  • Yoo, J.O.;Yang, H.J.;Cho, Y.C.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.4
    • /
    • pp.351-359
    • /
    • 1992
  • In order to improve the performance of heat exchanger, fluidized bed is often employed. The experiments are carried out in fluidized double pipe parallel flow heat exchanger in which finned tube is vertically immersed. And the heat transfer coefficients between the heated tube and fluidized bed of alumina beads(dp=0.41, 0.54, 0.65, 0.77mm) are calculated as a function of air fluidized velocity and pumping power. The effects of particle size, static bed height and pumping power on the heat transfer coefficients are investigated. And the heat transfer coefficients are compared with that of single phase forced convection heat exchanger. In particular, the heat transfer performance of each type heat exchanger is evaluated in relation to the pumping power.

  • PDF

The minimum fluidized velocity in fluidizing combustion bed of uniform particle size distribution system. (균일입자계 유동층연소로의 최소유동화 속도에 관한 연구)

  • 조병렬;김광렬
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.1
    • /
    • pp.39-44
    • /
    • 1996
  • The pressure fluctuations in a gas-solid fluidized bed has been analysed using s statistical method interpreting fluidized 냥d behavior. The performing statistical a analysis of the pressure fluctuations in a fluidized bed of 6.7cm-ID. using uniform p particle size of 115 to $1015{\mu}m$ in diameter. The fluidized gas used air(velocity 0.1~1.2m/sec) at settled bed height to diameter ratios which is LlD=l.O. Then, the pressure fluctuations measured by DPT(differantial pressure transducer). The measuring characteristic values of pressure fluctuation were the mean value and standard value, and also, it has been found that the standard deviation of the pressure fluctuations can be effectively used to predict minimum fluidizing velocity and to explain the fluidized phenomena.

  • PDF

Technical Development for the Circulating Fluidized Bed Combustor of firing Korean Low Grade Anthracite Coals (Particle Flow Patterns in a Circulating Fluidized-Bed with an internal Nozzle and a Partition Wall) (한국산 저질무연탄 연소용 순환식유동층 연소로 개발(간막이벽과 내부노즐을 설치한 순환유동층내에서의 유체거동))

  • Khee, Kwan-Seok
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.6 no.4
    • /
    • pp.243-248
    • /
    • 1993
  • A Circulating Fluidized-Bed (CFB) with an internal nozzle and a partition wall was proposed. The technique of fluidization is related to operations first used commercially in the fields of metallurgical and mechanical engineering such as the heat treatment of metals and power station combustors. In the modified CFB, an internal nozzle and a partition wall were additionally set in the main bed. This cold mode CFB apparatus made of acrylic resin; the main bed is 1,500mm high and 100mm in the inner diameter, the internal nozzle is 130mm high and 10mm in the inner diameter, and the partition wall is 7mm thick and 100mm in the diameter. Glass beads of $89{\mu}m$ in the mean diameter were employed as bed materials.

  • PDF

An Experimental Study on the Fluidization and Heat Transfer Characteristics in the Gas-Solid Fluidized Bed Furnace (기일고(氣一固) 유동층노내(流動層爐內) 유동화(流動化) 및 전열특성(傳熱特性)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Choi, Gug-Gwang;Park, Jong-Suen
    • Solar Energy
    • /
    • v.9 no.3
    • /
    • pp.55-63
    • /
    • 1989
  • In this paper, the fluidization characteristics of the magnesia fluidized bed and the heat transfer characteristics with the specimen (SM55C) plunged in the bed have been investigated. To characterize the fluidization, the minimum fluidizing velocities and the relation ships between bed voidage and fluidization rate and obtained. To characterize heat transfer, the experiments for finding heating time transfer effect have been carried out by varying the magnesia particles sizes. optimum heating condition in the magnesia fluidized bed is obtained.

  • PDF

Nitrate Removal by Immobilized Denitrifying Bacteria in Recirculating Aquaculture System (순환여과식 양식 시스템에 있어서의 고정화 탈진균에 의한 질산염 제거)

  • 김상희;김필균;김중균
    • Journal of Life Science
    • /
    • v.9 no.6
    • /
    • pp.698-703
    • /
    • 1999
  • For the nitrate removal in recirculating aquaculture system, a denitrifying bacterium, Pseudomonas fluorescens, was isolated from municipal sewage and the cells were immobilized in modified-polyvinly alchol (PVA) gel beads. The immobilized cells in both the fixed-and fluidized-bed reactors showed 98% of denitrification efficiency with 6hr HRT, and the removal efficiency of total organic carbon (TOC) was above 90%. Form scanning electron microscopy (SEM) observation, it was known that biofilm formed in fixed-bed reactor was thicker than that formed in fluidized-bed reactor as operation time passed.

  • PDF

Experimental Study on Electrostatic Hazards of Powder in Fluidized Bed (유동층 건조설비에 있어서 분진의 정전기 위험성에 관한 실험적 연구)

  • Moon, Kyoon-Tae;Chung, Jae-Hee;Choi, Kwang-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.4
    • /
    • pp.19-24
    • /
    • 2010
  • A large amount of electrostatic charges is often generated on polymer powders in fluidized bed and thereby may lead to electrostatic problems. In this study, to evaluate electrostatic hazards of powder in fluidized bed, the electric field(E[v/m]) and the charge amount(q[c/g]) during fluidizing were monitored. We also investigated the Minimum Ignition Energy(MIE [J]) of sample powder used in fluidized bed with the Hartman vertical-tube apparatus. The batch-type fluidized bed system and 2kg as Polypropylene(PP) resin powders were used in the experiments. The following results were obtained: (1) Even when a safe margin of several times was considered, the values of E obtained with PP powder in this paper did not exceed 3 to 5kV/cm, at which an incendiary electrostatic discharge could occur. (2) the ave. q was -0.26${\mu}$C/g during fluidizing. This value was high enough to cause electrostatic agglomeration and adhesion. (3) the entrained PP powder in upper column due to fluidizing could be ignited by electrostatic discharges of 71mJ.

A Study on the characteristics of the bed porosity and organic wastewater treatment with the circulation velocity in the anaerobic fluidized bed biofilm reactorA Study on the characteristics of the bed porosity and organic wastewater treatment with the circulation velocity in the anaerobic fluidized bed biofilm reactor (혐기성 유동층 생물막 반응기에서 순환유속 증가에 따른 층공극률 및 유기성 폐수 처리특성에 관한 연구)

  • 김재우;안재동
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.3
    • /
    • pp.1.1-15
    • /
    • 1995
  • This study was performed to estimate the characteristics of the organic wastewater treatment and bed porosity with the circulation velocity in the anaerobic fluidized bed biofilm reactor. The results were as follows; 1. With Increasing circulation velocity the fluidized bed expanded smooth and with increasing initial particle volume the fluidized bed was increased. 2. With increasing circulation velocity the gasproduction was increased, but at 1.Scnt/sec of circulation velocity AFBBR showed the highest value of methane production rate per removed COD. Therefore, for the purpose of economical operation in AFBBR, 1.5cm/sec of circulation velocity was optimum 3. The microorganisms were colonized in the crevice of the media. 4. On fluidization, COD, VA,55 profiles with the reactor height were not showed. In conclusion, AFBBR suit the organic wastewater treatment's purpose, and at 1.5cm/sec of circulation velocity the system is economical in an energy Point of view.

  • PDF

A Study on the Drying and Carbonization of Sewage Sludge in Fluidized Bed Reactor (유동층 반응기에서 하수슬러지의 건조 및 탄화 특성에 관한 연구)

  • Choung, Young-Hean;Cho, Ki-Chul;Kang, Dong-Hyo;Kim, Yi-Kwang;Park, Chang-Woong;Oh, Kwang-Joong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.7
    • /
    • pp.746-751
    • /
    • 2006
  • In this study, drying and carbonization experiment was conducted in a fluidized bed reactor according to the variations in gas velocity, particle size, and reactor temperature. As a result, the weight loss rates of sludge by drying in the fixed bed and fluidized bed type dryer showed that drying in the fluidized bed was about 6 times faster than drying in the fixed bed, and the weight loss rates of sludge by carbonization in the fixed bed and fluidized bed type reactor showed that carbonization in the fluidized bed was about 4 times faster than drying in the fixed bed. This implies that carbonization in the fluidized bed was completed within 10 minutes. Although the amount of char decreased with the increase of carboniration temperature, the amount of char became similar at upper 873K. Also, the amount of char decreased with increasing gas velocity. Consequently, it could be efficient that slow fluidization should be maintained within the range of fluidization in case of fluidized carbonization of sewage sludge at 873K.

The Effects of Desulfurization by Screen using Ca-based Absorbent in a Solid Waste Fluidized-bed Combustor (유동층연소로에서 제지공장 폐기물을 이용한 황산화물 제어시 스크린에 의한 탈황효과)

  • 조상원;이재홍;조기철;장상용;오광중
    • Journal of Environmental Science International
    • /
    • v.7 no.6
    • /
    • pp.783-791
    • /
    • 1998
  • The objectives of this study were to investigate the characteristics of desulfurization under different experimental conditions and the effects of desulfurization bed fluidized bed combuster installed with the screen. The experimental results were as follows ; First, as the height of fluidized bed combustor becomes higher, the concentrations of $SO_2$ mainly increased and sulfur retion of paper sludge was higher than that of natural limestone. Second, the desulfurzation by natural limestone occurred at in-bed and the desulfurization by paper sludge occurred in the whole of fluidized bed combuster. In addition, we identified calcium sulfate by the analysis of SEM and XRD. Third, screen at splash region increased sulfur retention 2~5%, air velocity and anthracite fraction had a little effect on the sulfur retention.

  • PDF

Electrostatic Charging Measurement and PVC Separation of Triboeletrostatically Charged Plastic Particles using a Fluidized Bed Tribocharger

  • Shin, Jin-Hyouk;Lee, Jae-Keun
    • Journal of ILASS-Korea
    • /
    • v.7 no.2
    • /
    • pp.7-15
    • /
    • 2002
  • A particle flow visualization, electrostatic charging measurement and separation of triboelectrically charged particles in the external electric field by a fluidized bed tribocharger are conducted for the removal of PVC particles from mixed waste plastics. The laboratory-scale triboelectrostatic separation system consists of the fluidized bed tribocharger, a separation chamber, a collection chamber and a controller. PVC and PET particles can be imparted negative and positive surface charges respectively due to the difference of triboelectric charging series between particles and particles in the fluidized bed tribocharger, and can be separated by passing them through an external electric field. To visualize these charged particles, He-Ne laser is used with cylindrical lenses to generate a sheet beam. In the charging measurement, the particle motion analysis system (PMAS), capable of determining particle velocity and diameter. is used to non-intrusively measure particle behavior in high strength electric field. The average charge-to-mass ratios of PVC and PET particles are $1.4\;and\;1.2{\mu}C/kg$, respectively. The highly concentrated PVC (91.9%) can be recovered with a yield of about 96.1% from the mixture of PVC and PET materials for a single-stage processing. The triboelectrostatic separation system using the fluidized tribocharger shows the potential to be an effective method for removing PVC from mixed plastics for waste plastic recycling.

  • PDF