• Title/Summary/Keyword: Fluid model

Search Result 4,517, Processing Time 0.041 seconds

Multi-fidelity uncertainty quantification of high Reynolds number turbulent flow around a rectangular 5:1 Cylinder

  • Sakuma, Mayu;Pepper, Nick;Warnakulasuriya, Suneth;Montomoli, Francesco;Wuch-ner, Roland;Bletzinger, Kai-Uwe
    • Wind and Structures
    • /
    • v.34 no.1
    • /
    • pp.127-136
    • /
    • 2022
  • In this work a multi-fidelity non-intrusive polynomial chaos (MF-NIPC) has been applied to a structural wind engineering problem in architectural design for the first time. In architectural design it is important to design structures that are safe in a range of wind directions and speeds. For this reason, the computational models used to design buildings and bridges must account for the uncertainties associated with the interaction between the structure and wind. In order to use the numerical simulations for the design, the numerical models must be validated by experi-mental data, and uncertainties contained in the experiments should also be taken into account. Uncertainty Quantifi-cation has been increasingly used for CFD simulations to consider such uncertainties. Typically, CFD simulations are computationally expensive, motivating the increased interest in multi-fidelity methods due to their ability to lev-erage limited data sets of high-fidelity data with evaluations of more computationally inexpensive models. Previous-ly, the multi-fidelity framework has been applied to CFD simulations for the purposes of optimization, rather than for the statistical assessment of candidate design. In this paper MF-NIPC method is applied to flow around a rectan-gular 5:1 cylinder, which has been thoroughly investigated for architectural design. The purpose of UQ is validation of numerical simulation results with experimental data, therefore the radius of curvature of the rectangular cylinder corners and the angle of attack are considered to be random variables, which are known to contain uncertainties when wind tunnel tests are carried out. Computational Fluid Dynamics (CFD) simulations are solved by a solver that employs the Finite Element Method (FEM) for two turbulence modeling approaches of the incompressible Navier-Stokes equations: Unsteady Reynolds Averaged Navier Stokes (URANS) and the Large Eddy simulation (LES). The results of the uncertainty analysis with CFD are compared to experimental data in terms of time-averaged pressure coefficients and bulk parameters. In addition, the accuracy and efficiency of the multi-fidelity framework is demonstrated through a comparison with the results of the high-fidelity model.

A Comparative Study on the Effect of Tamping Materials on the Impact Efficiency at Blasting Work (발파작업 시 충전매질에 따른 발파효과 비교 연구)

  • Bae, Sang-Soo;Han, Woo-Jin;Jang, Seung-Yup;Bang, Myung-Seok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.21 no.2
    • /
    • pp.57-65
    • /
    • 2022
  • This study simulated the shock wave propagation through the tamping material between explosives and hole wall at blasting works and verified the effect of tamping materials. The Arbitrary Lagrangian-Eulerian(ALE) method was selected to model the mixture of solid (Lagrangian) and fluid (Eulerian). The time series analysis was carried out during blasting process time. Explosives and tamping materials (air or water) were modeled with finite element mesh and the hole wall was assumed as a rigid body that can determine the propagation velocity and shock force hitting the hole wall from starting point (explosives). The numerical simulation results show that the propagation velocity and shock force in case of water were larger than those in case of air. In addition, the real site at blasting work was modeled and simulated. The rock was treated as elasto-plastic material. The results demonstrate that the instantaneous shock force was larger and the demolished block size was smaller in water than in air. On the contrary, the impact in the back side of explosives hole was smaller in water, because considerable amount of shock energy was used to demolish the rock, but the propagation of compression through solid becomes smaller due to the damping effect by rock demolition. Therefore, It can be proven that the water as the tamping media was more profitable than air.

RANS simulation of secondary flows in a low pressure turbine cascade: Influence of inlet boundary layer profile

  • Michele, Errante;Andrea, Ferrero;Francesco, Larocca
    • Advances in aircraft and spacecraft science
    • /
    • v.9 no.5
    • /
    • pp.415-431
    • /
    • 2022
  • Secondary flows have a huge impact on losses generation in modern low pressure gas turbines (LPTs). At design point, the interaction of the blade profile with the end-wall boundary layer is responsible for up to 40% of total losses. Therefore, predicting accurately the end-wall flow field in a LPT is extremely important in the industrial design phase. Since the inlet boundary layer profile is one of the factors which most affects the evolution of secondary flows, the first main objective of the present work is to investigate the impact of two different inlet conditions on the end-wall flow field of the T106A, a well known LPT cascade. The first condition, labeled in the paper as C1, is represented by uniform conditions at the inlet plane and the second, C2, by a flow characterized by a defined inlet boundary layer profile. The code used for the simulations is based on the Discontinuous Galerkin (DG) formulation and solves the Reynolds-averaged Navier-Stokes (RANS) equations coupled with the Spalart Allmaras turbulence model. Secondly, this work aims at estimating the influence of viscosity and turbulence on the T106A end-wall flow field. In order to do so, RANS results are compared with those obtained from an inviscid simulation with a prescribed inlet total pressure profile, which mimics a boundary layer. A comparison between C1 and C2 results highlights an influence of secondary flows on the flow field up to a significant distance from the end-wall. In particular, the C2 end-wall flow field appears to be characterized by greater over turning and under turning angles and higher total pressure losses. Furthermore, the C2 simulated flow field shows good agreement with experimental and numerical data available in literature. The C2 and inviscid Euler computed flow fields, although globally comparable, present evident differences. The cascade passage simulated with inviscid flow is mainly dominated by a single large and homogeneous vortex structure, less stretched in the spanwise direction and closer to the end-wall than vortical structures computed by compressible flow simulation. It is reasonable, then, asserting that for the chosen test case a great part of the secondary flows details is strongly dependent on viscous phenomena and turbulence.

Ficus vasculosa Wall. ex Miq. Inhibits the LPS-Induced Inflammation in RAW264.7 Macrophages

  • Ji-Won, Park;Jin-Mi, Park;Sangmi, Eum;Jung Hee, Kim;Jae Hoon, Oh;Jinseon, Choi;Tran The, Bach;Nguyen, Van Sinh;Sangho, Choi;Kyung-Seop, Ahn;Jae-Won, Lee
    • Microbiology and Biotechnology Letters
    • /
    • v.50 no.4
    • /
    • pp.574-583
    • /
    • 2022
  • Ficus vasculosa Wall. ex Miq. (FV) has been used as a herbal medicine in Southeast Asia and its antioxidant activity has been shown in previous studies. However, it has not yet been elucidated whether FV exerts anti-inflammatory effects on activated-macrophages. Thus, we aimed to evaluate the ameliorative property of FV methanol extract (FM) on lipopolysaccharide (LPS)-induced inflammatory responses and the underlying molecular mechanisms in RAW264.7 macrophages. The experimental results indicated that FM decreased the production of inflammatory mediators (NO/PGE2) and the mRNA/protein expression of iNOS and COX-2 in LPS-stimulated RAW264.7 cells. FM also reduced the secretion of interleukin (IL)-1β, IL-6, tumor necrosis factor (TNF)-α and monocyte chemoattractant protein (MCP)-1 in LPS-stimulated RAW264.7 cells. Results also demonstrated that FM improved inflammatory response in LPS-stimulated A549 airway epithelial cells by inhibiting the production of cytokines, such as IL-1β, IL-6 and TNF-α. In addition, FM suppressed MAPK activation and NF-κB nuclear translocation induced by LPS. FM also upregulated the mRNA/protein expression levels of heme oxygenase-1 and the nuclear translocation of nuclear factor erythroid 2-related factor 2 in RAW264.7 cells. In an experimental animal model of LPS-induced acute lung injury, the increased levels of molecules in bronchoalveolar lavage (BAL) fluid were suppressed by FM administration. Collectively, it was founded that FM has anti-inflammatory properties on activated-macrophages by suppressing inflammatory molecules and regulating the activation of MAPK/NF-κB signaling.

Analysis of Thermal Environment Impact by Layout Type of Apartment Complexes for Carbon Neutrality Net-Zero: Based on CFD Simulation (공동주택단지 배치유형별 열환경 영향성 분석: 유체역학 시뮬레이션을 기반으로)

  • Gunwon Lee;Youngtae Cho
    • Land and Housing Review
    • /
    • v.14 no.3
    • /
    • pp.93-106
    • /
    • 2023
  • This study attempted to simulate changes in the thermal environment according to the type of apartment complex in Korea using CFD techniques and evaluate the thermal environment by type of apartment. First, apartment complex types in the 2000s and 2010s were referred from previous studies and four types of apartment complex were extracted from. Second, the layout of the apartment complex and temperature changes were analyzed by the direction of wind inflow. Third, a standardized model was created from each type using tower type, plate type, and mixed driving. Last, CFD simulations were performed by setting up the inflow of wind from a total of eight directions. The temperature was relatively low in the type consisting of only the tower type and the type of placing the tower type in the center of the complex, regardless of the direction of the wind. It was due to the good inflow of wind from these types to the inside of the complex. It can be interpreted because wind flows easily into the complex in these types. The findings showed that wind flow and resulting temperature distribution patterns differed depending on the building type and complex layout type, confirming the need for careful consideration of the complex layout in the early design stage. The results are expected to be used as basic data for creating a sustainable residential environment in the early design stage of apartment complexes in the future.

Study of the Mitigation of Algae in Lake Uiam according to the Operation of the Chuncheon Dam and the Soyang Dam (춘천댐 및 소양강댐 운영에 따른 의암호 조류 저감 연구)

  • Lee, Dong Yeol;Baek, Kyong Oh
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.2
    • /
    • pp.171-179
    • /
    • 2022
  • In this study, the characteristics of algae mitigation according to dam operation were quantitatively analyzed for Uiam Lake, where the Chuncheon Dam is located upstream of the main stream, Uiam Dam is located downstream, and Soyang Dam is located in the tributary stream. Nine dam operation scenarios were applied to the event of the summer of 2018 (at that time an algae alert occurred) using the EFDC model, which is capable of calculating three-dimensional hydrodynamics and water quality levels such as those associated with chlorophyll-a. The dam operation scenarios were set to generate a flushing effect via discharges in the form of pulse waves from the upstream dams and by lowering the water level at the downstream dam. At Uiam Lake, the flushing effect was different depending on the operation of the dam, and the amount of algae reduction at each point was different owing to topographic characteristics and the different base water temperatures from BukHan River and Soyang River. With regard to a point located on the left bank, it was predicted that the peak level of chlorophyll-a would be reduced by approximately 50 % or more upon pulsed discharge at 50 m3/s for three days at Soyang Dam. However, for the right bank, the amount of discharge from Soyang Dam had little effect on algae mitigation. Therefore, an appropriate dam operation could be effective for algae mitigation at specific points in the water body where large dams exist upstream and downstream, such as at Uiam Lake, in an emergency situation in which algal blooms rapidly.

Backflow Flow Analysis of Street Inlet drain using Fluent Model (빗물받이 연결관 역류 흐름 해석을 위한 Fluent 모형 적용)

  • Lee, Min Sung;Kim, Jung Soo;Yoo, In Gi;Yoo, Kyu Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.245-245
    • /
    • 2022
  • 최근 국내 기후변화에 따른 국지성 집중호우로 인한 시간당 강우량의 증가로 도로부 유출량의 증가와 배수관거에서의 내수배제 불량에 따른 도심지 내수침수 피해가 증가함에 따라 이를 해결하기 위한 우수유출저감시설이 설치되고 있다. 그러나 대단위의 지하 저류시설의 지속적인 설치는 과밀화된 도심지에서 설치 지하공간의 구조적인 한계 및 적정 설치 위치의 미확보 등의 다양한 문제가 발생하여 저류시설의 침수저감 효과에 대한 추가적이고 새로운 저류시설에 대한 연구가 필요한 실정이다. 이에 내수 침수 저감 및 배수 능력 향상을 위한 도로 배수시설과 연계된 도로 측구부 저류시스템 구축이 필요하다. 이를 위해 역류 방지 및 노면수 저류 빗물받이에 적용되는 부력식 역류차단장치를 개발하였으며, 역류차단장치의 최적 형상 개발을 위해서 기존 빗물받이 연결관과의 통수능 비교 및 분석이 필요한 실정이다. 따라서 본 연구에서는 기존 빗물받이 연결관 및 연결관 내에 역류차단장치가 적용된 역류차단 빗물받이의 흐름분석을 위해 Fluent 모형을 이용하여 3차원 수치모의를 수행하였다. 수치모의 구성으로는 전체 형상을 40×50cm의 빗물받이 유입부와 50×50cm의 빗물받이로 결정하고 격자는 빗물받이 내부의 복잡한 3차원 흐름을 모의하기 위해 1.2~2mm 크기로 생성하였다. 다상유동 해석을 위해 VOF(Volume of Fluid)방법을 적용하였고, 수치해석 방법으로는 비정상류, 난류 모형으로는 SST k-𝜔모형을 적용하였다. 해석조건으로는 김정수(2021) 등이 제시한 4차선 기준 설계빈도별(5~30년) 빗물받이 유입유량을 산정하여 빗물받이 유입조건으로 선정하였으며, 빗물받이와 연결관에서의 통수능력 분석 조건으로는 빗물받이에 기존 연결관이 부착된 조건과 연결관 내에 역류차단장치가 설치되어 역류차단장치가 개방된 조건에서의 통수능을 비교하였으며, 역류상황을 가정한 연결관에서의 통수능을 비교하기 위하여 역류차단장치의 개폐정도를 15도(통수단면 33%감소) 닫힌 상태 및 30도(통수단면 67% 감소) 닫힌 상태 조건을 대상으로 빗물받이와 연결관에서의 흐름을 모의하였다. 수치모의 결과 역류차단장치의 계폐조건에 상관없이 5년 빈도유입량 조건에서는 완전 배수가 되었으며, 개폐조건 15도에서는 10년 빈도의 유입량에서는 완전 배수가 되었으나 20년 빈도 이상의 유입량 조건에서 빗물받이 유입부로의 역류가 발생하였으며, 개폐조건 30도에서는 5년 빈도 이상 유입량 조건에서 빗물받이 유입부로 역류가 발생하는 것으로 나타났다. 특히, 30년 빈도 이상의 유입량부터는 빗물받이 연결관 내에 역류차단장치 개페조건과 관계없이 빗물받이 유입부로의 역류로 인한 도로 침수가 발생하기 때문에 유휴공간인 도로 측구부를 저류공간으로 활용할 수 있는 도로 측구부 저류시스템의 구축은 필수적이라고 판단되며, 유량 조건에 따른 빗물받이 내부 와 흐름과 유출부에서의 유속 변화 특성을 확인하였다. 그러므로 측구 저류조 개발 형상과 연결한 3차원 흐름의 구현 및 분석에 Fluent 모형의 적용이 가능하다고 판단된다.

  • PDF

Flow Analysis in Road Gutter Storage Using Fluent Model (Fluent 모형을 이용한 도로 측구 저류조에서의 흐름 분석)

  • Kim, Jung Soo;Lee, Min Sung;Han, Chyung Such;Yoo, In Gi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.234-234
    • /
    • 2022
  • 도로에서의 우수를 원활하게 처리하기 위해서 빗물받이 및 연결관 등의 노면 배수시설이 설치되고 있으며, 노면 배수는 측구부를 통해 흘러 빗물받이 유입부로 차집되고 연결관을 통해 하수관거로 배수된다. 그러나 최근 국내 기상패턴의 변화로 국지성 집중호우와 같이 시간당 강우량 증가로 도로부와 저지대에서 배수시설의 배수불량에 따른 도심지 내수침수 피해가 발생하고 있다. 이에 정부에서는 다양한 우수관거 개선사업, 빗물펌프장, 지하저류조와 같은 방재시설을 설치하고 있으나 우수유출저감시설은 대규모 예산이 소요되고 실제 침수지역에 피해 저감효과에 대한 효용성 문제에 대한 제기뿐만 아니라 과밀화된 도심지에서는 지하공간 활용에 한계가 있는 실정이므로 도심지의 다양한 공간을 활용한 도시 배수 및 저류시설에 대한 연구가 필요하다. 따라서 본 연구에서는 유휴 공간인 도로 측구부 공간을 활용하여 도로 노면수를 저류 및 지체할 수 있는 노면수 측구 저류시설의 개념을 제시하고 측구저류조의 활용성을 판단하기 위하여 빗물받이 유입구, 빗물받이, 측구 저류조 및 빗물받이와 측구저류조 연결부에서의 노면수 유입, 유출 및 저류 등의 다양한 흐름 변화를 확인하기 위하여 Fluent 모형의 적용성을 분석하였다. 수치모의 전체 형상은 50x50cm 크기의 빗물받이를 기준으로 양쪽에 2m 길이의 측구 저류조를 원형관으로 연결하여 1/5 축소모형으로 구성하고 격자는 빗물받이 유입부, 빗물받이 및 측구 저류조 내부의 복잡한 3차원 흐름을 모의하기 위해 사면체와 육면체로 조밀하게 생성하였다. 다상유동해석을 위해 VOF(Volume of Fluid)방법을 적용하였고, 수치해석 방법으로는 비정상류, 난류 모형으로는 SST k-ω모형을 적용하였다. 수치모의 조건으로는 설계빈도별(5~30년) 우수유출량을 산정하여 유입 유량별 기존 빗물받이 유입부에서의 유입흐름, 빗물받이 내부에서의 와 발생흐름, 측구 저류조 및 연결관에서의 흐름을 구현하여 분석하였다. 수치모의 결과 빗물받이 유입부에서 연결관을 통한 측구 저류조로 유입되는 유입흐름과 빗물받이 하단부의 배수관을 통해 유출되는 흐름을 정상적으로 구현하였으며, 빗물받이 유입부 및 측구 저류조 연결관에서의 유속변화도 확인할 수 있었다. 또한 빗물받이와 측구 저류조에서 다양한 흐름을 구현하기 위한 Flunet 모형의 적용성을 검토하였으며, 향후 수리실험을 통하여 실제 흐름과의 매개변수 최적화 및 다양한 도로 조건의 변화를 고려한 수치모의 분석을 통하여 지속적인 모형의 검증이 가능할 것으로 판단된다.

  • PDF

Optimization of impeller blade shape for high-performance and low-noise centrifugal pump (고성능 저소음 원심펌프 개발을 위한 임펠러 익형 최적설계)

  • Younguk Song;Seo-Yoon Ryu;Cheolung Cheong;Tae-hoon Kim;Junhyo Koo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.519-528
    • /
    • 2023
  • The aim of this study was to enhance the flow rate and noise performance of a centrifugal pump in dishwashers by designing an optimized impeller shape through numerical and experimental investigations. To evaluate the performance of the target centrifugal pump, experiment was conducted using a pump performance tester and noise experiment was carried out in a semi-anechoic chamber with microphones and a reflecting wall behind the dishwasher. Through the use of advanced computational fluid dynamics techniques, numerical simulations were performed to analyze the flow and aeroacoustics performance of our target centrifugal pump impeller. To achieve this, numerical simulations were carried out using the Reynolds-Average Navier-Stokes equations and Ffowcs-Willliams and Hawkings equations as governing equations. In order to ensure the validity of numerical methods, a thorough comparison of numerical results with experimental results. After having confirmed the reliability of the current numerical method of this study, the optimization of the target centrifugal pump impeller was conducted. An improvement in flow rate was confirmed numerically, and a manufactured proto-type of the optimized model was used for experimental investigation. Furthermore, it was observed that by applying the fan law, we could effectively reduce noise levels without reducing the flow rate.

Numerical and experimental investigations on the aerodynamic and aeroacoustic performance of the blade winglet tip shape of the axial-flow fan (축류팬 날개 끝 윙렛 형상의 적용 유무에 따른 공기역학적 성능 및 유동 소음에 관한 수치적/실험적 연구)

  • Seo-Yoon Ryu;Cheolung Cheong;Jong Wook Kim;Byeong Il Park
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.103-111
    • /
    • 2024
  • Axial-flow fans are used to transport fluids in relatively low-pressure flow regimes, and a variety of design variables are employed. The tip geometry of an axial fan plays a dominant role in its flow and noise performance, and two of the most prominent flow phenomena are the tip vortex and the tip leakage vortex that occur at the tip of the blade. Various studies have been conducted to control these three-dimensional flow structures, and winglet geometries have been developed in the aircraft field to suppress wingtip vortices and increase efficiency. In this study, a numerical and experimental study was conducted to analyze the effect of winglet geometry applied to an axial fan blade for an air conditioner outdoor unit. The unsteady Reynolds-Averaged Navier-Stokes (RANS) equation and the FfocwsWilliams and Hawkings (FW-H) equation were numerically solved based on computational fluid dynamics techniques to analyze the three-dimensional flow structure and flow noise numerically, and the validity of the numerical method was verified by comparison with experimental results. The differences in the formation of tip vortex and tip leakage vortex depending on the winglet geometry were compared through a three-dimensional flow field, and the resulting aerodynamic performance was quantitatively compared. In addition, the effect of winglet geometry on flow noise was evaluated by numerically simulating noise based on the predicted flow field. A prototype of the target fan model was built, and flow and noise experiments were conducted to evaluate the actual performance quantitatively.