• 제목/요약/키워드: Fluid injection

검색결과 692건 처리시간 0.02초

Visualization of Flow inside a Regenerative Turbomachinery

  • Yang, Hyeonmo;Lee, Kyoung-Yong;Choi, Youngseok;Jeong, Kyungseok
    • International Journal of Fluid Machinery and Systems
    • /
    • 제7권2호
    • /
    • pp.80-85
    • /
    • 2014
  • In this study, we visualized the internal flow of a regenerative turbomachinery using the direct injection tracer method. For visualization, the working fluid was water and the tracer was oil colors (marbling colors). Droplets were injected at the inlet of the machinery and the streak were recorded using a high-speed camera with high-power light sources. While circulating inside the groove, the droplets were translated by the rotational motion of the impeller. When the droplets flow out of the impeller groove, relative to the impeller, they moved more slowly. And the droplets repeatedly reentered into the groove and circulated again. Then the droplets either flowed to the outlet or to the stripper. As a result, this experiment has confirmed the internal circulating flow of a regenerative turbomachinery.

마필의 퇴행성 관절증에 대한 Sodium hyaluronate와 Polysulfated glycosaminoglycan의 관절강내 투여효과 (Effect of Intra-articular Injection of Sodium Hyaluronate and Polysulfated Glycosaminoglycan in Equine Degenerative Joint Disease)

  • 김병선;최희인
    • 한국임상수의학회지
    • /
    • 제8권1호
    • /
    • pp.11-26
    • /
    • 1991
  • The effects of intra-articula. sodium hyaluronate(SH) and polysulfated glycosaminoglycan(PSGAG) on degenerative joint disease of the carpus were compared each other In 20 racehorses. Ten horses were dosed with intra-articula. injection of 20mg SH(2 times/2 weeks interval) and ten horses were dosed with intra-articular injection of 250mg of PSGAG(4 times/1 week into.val). Synovial fluid analysis and clinical examination were made to evaluate the effects of the drugs on degenerative joint disease at before injection and 2 weeks after the last injection, respectively. Appearance and mucinous precipitate quality oi synovial fluids of the group injected with 58 and PSGAG were improved by 40~50% and 60~80%, respectively. The chemical values of alkaline phosphatase, lactic dehydrogenase, aspartate aminotransferase, total protein, A/G ratio and glucose of synovial fluid in the group injected with PSGAG were more clearly returned to the normal values than those of the group injected with SH. Relative viscosity and total white blood cells of synovial fluid were returned to the normal walues after the treatments in both groups. Clinical symptoms(swelling, heat and pain on carpal joint, and lameness) of the horses in the group injected with SH and PSGAG were disappeard by 56~67% and 67~80%, respectivelty. Conclusively, the PSGAG was superior to SH in the effects on treatment of the degenerative joint disease in the horses.

  • PDF

Bolus Injection 방법을 이용해서 측정한 정상 성인의 뇌척수액 배출저항 (Resistance to Cerebrospinal Fluid Outflow Measured by Bolus Injection Method in Normal Adults)

  • 김은영;박현선;정종권;진태경;김재중;박형천
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권9호
    • /
    • pp.1209-1214
    • /
    • 2000
  • Objectives : The measurement of resistance to cerebrospinal fluid outflow($R_o$) can clearly delineate cerebrospinal fluid dynamics in patients with ventricular dilatation and can help in selecting patients to undergo shunt placement. With regards to type of infusion method, bolus injection is known to be more practical and safer than continuous infusion. The purpose of this study was to obtain $R_o$ of normal adults using lumbar bolus injection method. Material and Methods : Twenty adults aged 25 to 52 years were studied using lumbar bolus injection method. Fifteen patients with hemifacial spasm and five with cerebral concussion underwent $R_o$ measurement under propofol general anesthesia and local anesthesia, respectively. Results : The mean values of $R_o$ determined 1 minute and 2 minutes after bolus injection were $4.8{\pm}1.7$ and $4.4{\pm}1.6mmHg/ml/min$, respectively. There was no significant difference of $R_o$ between propofol general anesthesia group and local anesthesia group. Two patients showed $R_o$ greater than 6mmHg/ml/min. One patient revealed unexpectedly high level of $R_o$ due to severe spinal stenosis. Conclusion : Mean Ro in this study was higher than that of Shapiro's study. Borderline Ro near 6mmHg/ml/min should be regarded with caution and compared with clinical symptoms and results of other studies. Patients with severe spinal stenosis should be evaluated with caution.

  • PDF

Study on bubble detection sensor for safe sap and blood injection

  • Yun, Young Gi;Lee, Hoo Young;Park, Koo Rack
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권9호
    • /
    • pp.149-154
    • /
    • 2017
  • The infusion of fluid and blood is necessary in the ward, operating room, recovery room, neonatal room, etc. for nutrition and blood supply to the patient, but air bubbles generated during infusion of fluid and blood circulate along the artery or vein. Serious illnesses occur and there is also a risk of death. In this paper, we propose a medical bubble detection system, a bubble detection system, a bubble detection alarm system, and a communication method in order to develop a safer fluid and blood injection system in the existing system, which is detected by a medical staff monitoring system or an ultrasonic bubble detection sensor In this study, infrared rays are transmitted to a tube through a tube for injecting fluid or blood into a patient, infrared rays transmitted by an infrared ray emitting section are received, and the amount of light is measured in real time. Based on the data, we study how to detect and analyze the presence of bubbles in fluid and blood.

Ammonia and Hydrogen Sulfide Removal from Swine House Exhaust Air Using a Dip Injection Wet Scrubber

  • Shin, Myeongcheol;Lee, Seunghun;Wi, Jisoo;Ahn, Heekwon
    • 한국토양비료학회지
    • /
    • 제50권6호
    • /
    • pp.615-622
    • /
    • 2017
  • This study was conducted to evaluate the odor reduction efficacy of the dip injection wet scrubber (DIWS) using tap water as washing fluid. The $NH_3$ and $H_2S$ removal efficiency of 7 day batch operated DIWS was evaluated twice over a total of 14 days of experiment. The $NH_3$ removal efficiency ranged from 26 to 37%. The $H_2S$ removal efficiency was between 22 and 30%. The pH of the washing fluid maintained below 8 and the $NH_4{^+}$ concentration tended to keep constant around 350 ppm after 5 days of washing-fluid replacement. Therefore, the 5-day washing fluid replacement interval is more preferable than the 7-day interval. The $NH_4{^+}$ concentration and the electrical conductivity (EC) showed a high correlation. The EC measurement can be used as an alternative to conventional $NH_4{^+}$ concentration measurement method for real time monitoring of washing fluid condition.

Seismic wave monitoring of $CO_2$ migration in water-saturated porous sandstone

  • Xue Ziqiu;Ohsumi Takashi
    • 지구물리와물리탐사
    • /
    • 제7권1호
    • /
    • pp.25-32
    • /
    • 2004
  • We have carried out laboratory measurements of P-wave velocity and deformation strain during $CO_2$ injection into a porous sandstone sample, in dry and water-saturated conditions. The rock sample was cylindrical, with the axis normal to the bedding plane, and fluid injection was performed from one end. Using a piezoelectric transducer array system, we mapped fluid movement during injection of distilled water into dry sandstone, and of gaseous, liquid, and supercritical $CO_2$ into a water-saturated sample. The velocity changes caused by water injection ranged from $5.61\;to\;7.52\%$. The velocity changes caused by $CO_2$ injection are typically about $-6\%$, and about $-10\%$ for injection of supercritical $CO_2$, Such changes in velocity show that the seismic method may be useful in mapping $CO_2$ movement in the subsurface. Strain normal to the bedding plane was greater than strain parallel to the bedding plane during $CO_2$ injection; injection of supercritical $CO_2$ showed a particularly strong effect. Strain changes suggest the possibility of monitoring rock mass deformation by using borehole tiltmeters at geological sequestration sites. We also found differences associated with $CO_2$ phases in velocity and strain changes during injection.

Gas-lift를 이용한 극저온 추진제의 재순환 성능에 대한 실험 (Experimental Study on Cryogenic Propellant Circulation using Gas-lift)

  • 권오성;이중엽;정용갑
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.551-554
    • /
    • 2006
  • Inhibition of propellant temperature rising in liquid propulsion rocket using cryogenic fluid as a propellant is very important. Especially propellant temperature rising during stand-by after filling and pre-pressurization can bring into cavitation in turbo-pump. One of the method preventing propellant temperature rising in cryogenic feeding system is recirculating propellant through the loop composed of propellant tank, feed pipe, and recirculation pipe. The circulation of propellant is promoted through gas-lift effect by gas injection to lower position of recirculation pipe. In this experiment liquid oxygen and gas helium is used as propellant and injection gas. Under atmospheric and pressurized tank ullage condition, helium injection flow-rate is varied to observe the variation of recirculating flow-rate and propellant temperature in the feed pipe. There is appropriate helium injection flow-rate for gas-lift recirculation system.

  • PDF

HALL EFFECTS ON HYDROMAGNETIC NATURAL CONVECTION FLOW IN A VERTICAL MICRO-POROUS-CHANNEL WITH INJECTION/SUCTION

  • BHASKAR, P.;VENKATESWARLU, M.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제24권1호
    • /
    • pp.103-119
    • /
    • 2020
  • In this work, the hydromagnetic and thermal characteristics of natural convection flow in a vertical parallel plate micro-porous-channel with suction/injection is analytically studied in the presence of Hall current by taking the temperature jump and the velocity slip at the wall into account. The governing equations, exhibiting the physics of the flow formation are displayed and the exact analytical solutions have been obtained for momentum and energy equations under relevant boundary conditions. The impact of distinct admissible parameters such as Hartmann number, Hall current parameter, permeability parameter, suction/injection parameter, fluid wall interaction parameter, Knudsen number and wall-ambient temperature ratio on the flow formation is discussed with the aid of line graphs. In particular, as rarefaction parameter on the micro-porous-channel surfaces increases, the fluid velocity increases and the volume flow rate decreases for injection/suction.

유체의 관성력과 스월의 영향을 고려한 난류 하이브리드 베어링의 해석 (An Analysis for Turbulent Hybrid Bearings with Fluid Inertia and Swirl Injection Effects)

  • 이용복;김창호;최동훈
    • Tribology and Lubricants
    • /
    • 제12권3호
    • /
    • pp.85-91
    • /
    • 1996
  • An analysis for turbulent hybrid beatings with fluid inertia and swirl injection effect was derived for studying static characteristics of swirl-controlled hybrid journal. The swirl-controlled hybrid journal beating is considered to have more freedom in stability control in high speed rotating machinery. Current analysis is compared with experimental results with 3-recess hydrostatic journal bearing. The analysis revealed that the fluid momentum exchange at orifice discharge could produce pressure rise inside the recess region which can control the shear flow induced by journal rotation. The analysis also shows that the swirl-controlled hybrid journal beating has a capability of controlling load carrying capacity and stability by manipulating supply pressure and injection angle.

초임계 CO2 사이클에서 가스 인젝션이 압축기 성능에 미치는 영향 (Effects of Vapor Injection on a Compressor in a Transcritical CO2 Cycle)

  • 김우영;심재휘;이용호;김현진
    • 한국유체기계학회 논문집
    • /
    • 제10권2호
    • /
    • pp.16-21
    • /
    • 2007
  • Potential advantages of using vapor injection in a two stage rotary compressor for a $CO_2$ heat pump water heater system were addressed in this paper by numerical simulation. Vapor separated from a flash tank in the middle of the expansion process can be used for injection into the second stage suction plenum of the compressor to improve the system performance. Vapor injection increases the intermediate pressure between the two stages, thus increasing the first stage compressor work and reducing that of the second stage. As a whole, however, the compressor input power increases due to injected mass flow rate for the second stage. Computer simulation showed that increment of the cooling capacity by vapor injection exceeded that of the compressor work, thus improving the system performance. COP improvement by vapor injection was calculated to be about 5-14% for normal operating conditions. With vapor injection, a maximum COP was found when the displacement volume of the second stage becomes 90-95% of that of the first stage of the compressor.