• 제목/요약/키워드: Fluid injection

검색결과 692건 처리시간 0.027초

직접분사 CNG 연료의 분사특성에 관한 연구 (A Study on the Injection Characteristics of Direct Injection CNG Fuel)

  • 이성욱;;;김인구;강호인
    • 한국수소및신에너지학회논문집
    • /
    • 제25권6호
    • /
    • pp.643-647
    • /
    • 2014
  • Two types of fuel supply method ar used in CNG vehicles. One is premixed ignition and the other is gas-jet ignition. In premixed ignition, the fuel is introduced with intake air so that homogeneous air-fuel mixture may form. The ignitability of this method depends on the global equivalence ratio. In gas-jet ignition, CNG is introduced directly into the engine combustion chamber. The overall mixture is stratified by retarded fuel injection. In this study, a visualization technique was employed to obtain fundamental properties regarding overall mixture formation of direct injected CNG fuel inside a constant volume chamber. Jet angles, penetrations and projected jet area with respect to ambient pressure are investigated. The penetration decreases apparently and the time reaching the CVC wall was delayed as the chamber pressure increases. This is caused by the higher inertia of the fluid elements that the injected fluid must accelerate and push aside. It is same to liquid fuel such as diesel and gasoline, but this phenomenon is far more prominent for the gaseous fuel.

NON LINEAR VARIABLE VISCOSITY ON MHD MIXED CONVECTION HEAT TRANSFER ALONG HIEMENZ FLOW OVER A THERMALLY STRATIFIED POROUS WEDGE

  • Kandasamy, R.;Hashim, I.;Ruhaila, K.
    • Journal of applied mathematics & informatics
    • /
    • 제26권1_2호
    • /
    • pp.161-176
    • /
    • 2008
  • The effect of variable viscosity on MHD mixed convection Hiemenz flow over a thermally stratified porous wedge plate has been studied in the presence of suction or injection. The wall of the wedge is embedded in a uniform Darcian porous medium in order to allow for possible fluid wall suction or injection and has a power-law variation of the wall temperature. An approximate numerical solution for the steady laminar boundary-layer flow over a wall of the wedge in the presence of thermal diffusion has been obtained by solving the governing equations using numerical technique. The fluid is assumed to be viscous and incompressible. Numerical calculations are carried out for different values of dimensionless parameters and an analysis of the results obtained shows that the flow field is influenced appreciably by the magnetic effect, variable viscosity, thermal stratification and suction / injection at wall surface. Effects of these major parameters on the transport behaviors are investigated methodically and typical results are illustrated to reveal the tendency of the solutions. Comparisons with previously published works are performed and excellent agreement between the results is obtained.

  • PDF

2단 유량제어 Fluidic Device의 특성에 관한 연구 (A Study on the Characteristics of Two-Step-Flow-Control Fluidic Device)

  • 조봉현;배윤영;박종균;유성연
    • 한국유체기계학회 논문집
    • /
    • 제4권3호
    • /
    • pp.53-61
    • /
    • 2001
  • Vortex type Fluidic Device(FD) which is installed at the bottom of Safety Injection Tank(SIT) controls the discharge flow rate from the tank. In case of loss of coolant accident the injection water flows into primary system in two steps; initial high flow rate for certain period of time and subsequent low flow rate. By two-step control of the discharge flow rate, FD can ensure the effective use of water in the tank. A small-scale FD has been tested to obtain a required flow characteristics maintaining full pressure and height of prototype, which are the major contributing parameters. Through the testing of many different arrangements of internal geometry of FD, most appropriate one was selected and its performance data was obtained. As characteristics of FD, time dependent Euler number, flow rate and pressure are presented and discussed. Also a method to predict the full size FD is presented.

  • PDF

냉각홀 형상 변화에 따른 원형봉 선단의 막냉각 특성 연구 (A Study of Film Cooling of a Cylindrical Leading Edge with Shaped Injection Holes)

  • 김성민;김윤제;조형희
    • 한국유체기계학회 논문집
    • /
    • 제6권3호
    • /
    • pp.21-27
    • /
    • 2003
  • Dispersion of coolant jets in a film cooling flow field is the result of a highly complex interaction between the film cooling jets and the mainstream. In order to investigate the effect of blowing ratios on the film cooling of a turbine blade, cylindrical body model is used. Mainstream Reynolds number based on the cylinder diameter is $7.1{\times}10^4$. The effects of coolant flow rates are studied for blowing ratios of 0.7, 1.0, 1.3 and 1.7, respectively. The temperature distribution of the cylindrical model surface is visualized with infrared thermography (IRT). Results show that the film cooling performance could be significantly improved by the shaped injection holes. For higher blowing ratio, the spanwise-diffused injection holes are better due to the lower momentum flux away from the wall plane at the hole exit.

회전하는 충돌제트/유출냉각기법에서 분사홀 변화에 따른 열/물질전달 특성 (Heat/Mass Transfer Characteristics for Variation of Injection Hole in Rotating Impingement/Effusion Cooling System)

  • 홍성국;조형희
    • 한국유체기계학회 논문집
    • /
    • 제10권3호
    • /
    • pp.25-32
    • /
    • 2007
  • The present paper deals with the heat/mass transfer characteristics for the rotating impingement/effusion cooling system. By changing the size and number of injection hole, its effects on heat/mass transfer are investigated and three different injection hole cases are considered such as LH, DH and SH, respectively. Reynolds number based on the effusion hole diameter is fixed to 3,330 and two jet orientations are considered. A naphthalene sublimation method is used to obtain the heat/mass transfer coefficients on the effusion plate. The LH case shows that the local heat/mass transfer is significantly varied by the rotation. Moreover, the low and non-uniform Sh distributions occur because the impinging jet is deflected by Coriolis force. Meanwhile, for DH and SH cases, the local heat/mass transfer coefficients are enhanced significantly compared to LH case and the rotation effect decreases with increasing the jet velocity. The averaged Sh value of DH and SH case rises up to 45%, 85% than that of LH case. However, the uniformity of heat/mass transfer deteriorates due to the steep variation of heat/mass transfer.

고압 피스톤 펌프용 슬리퍼 베어링의 변형 특성에 관한 연구 (A Study on the Deformation Characteristics of a Slipper Bearing for High Pressure Piston Pump)

  • 고성위;김병탁
    • 한국해양공학회지
    • /
    • 제23권5호
    • /
    • pp.39-44
    • /
    • 2009
  • The hydrostatic slipper bearing is generally used in high pressure axial piston pumps to support the load generated from two surfaces which are sliding relatively at low speed. The object of the bearing is to remove the possibility of direct contact by maintenance of an adequate oil film thickness between two metal surfaces. Because the bearing performance is influenced by the bearing deformation, it is highly dependent on the injection pressure, the bearing surface profile and so on. In this study, the deformation characteristics of a hydrostatic slipper bearing is investigated according to the injection pressure by the finite element analysis. In the analysis, the special boundary condition to take the fluid-structure interaction (FSI) into account is used on the interactive surface. The results, such as bearing deformation, stress and lifting force, obtained from the fully coupled analysis are compared with those from the single step sequential method.

터빈 블레이드 온도 변화를 고려한 증기분사 가스터빈 열병합발전 시스템의 성능해석 (Performance Analysis of a Steam Injected Gas Turbine Combined Heat and Power System Considering Turbine Blade Temperature Change)

  • 강수영;김정호;김동섭
    • 한국유체기계학회 논문집
    • /
    • 제15권6호
    • /
    • pp.18-24
    • /
    • 2012
  • This study simulated the operation of a steam injected gas turbine combined heat and power (CHP) system. A full off-design analysis was carried out to examine the change in the turbine blade temperature caused by steam injection. The prediction of turbine blade temperature was performed for the operating modes suggested in the previous study where the limitation of compressor surge margin reduction was analyzed in the steam injected gas turbine. It was found that both the fully injected and partially injected operations suggested in the previous study would cause the blade temperature to exceed that of the pure CHP operation and the under-firing operation would provide too low blade temperature. An optimal operation was proposed where both the turbine inlet temperature and the injection amount were modulated to keep both the reference turbine blade temperature and the minimum compressor surge margin. The modulation was intended to maintain a stable compressor operation and turbine life. It was shown that the optimal operation would provide a larger power output than the under-firing operation and a higher efficiency than the original partially injected operation.

전산유체를 활용한 정수공정에서 후염소 투입공정 최적설계 방안 (Most suitable design method of post-chlorination process in portable water process by using CFD)

  • 조영만
    • 상하수도학회지
    • /
    • 제27권3호
    • /
    • pp.331-337
    • /
    • 2013
  • Post-chlorination for disinfection in portable water process is final process. The design factors of post-chlorination are inflow pipe line from tank of filtrated water to cleanwell, injection point of chlorine, appropriate shape of baffle in cleanwell for disinfection efficient improvement. Until now, we did not have the design standard for post-chlorination. we evaluated most suitable design method of post-chlorination process in portable water process by using computational fluid dynamics in this research. We found the result that the pipe to connect the cleanwell should be one. If pipe line split into two or more, uniform distribution of the flow is difficult. Second, optimal injection point of chlorine is the middle of pipe line to connect the cleanwell. Therefore, it is not economical to install chlorine contact basin in cleanwell. Third, the shape of baffle should be designed in order to water flows in one direction. And we found that it is better to design the low number of flow turning.

요부 경막외 스테로이드 주입 후 발생한 무균성 수막염 -증례 보고- (Aseptic Meningitis after a Lumbar Epidural Steroid Injection -A case report-)

  • 황병문;임정길
    • The Korean Journal of Pain
    • /
    • 제18권1호
    • /
    • pp.52-55
    • /
    • 2005
  • Complications following a well conducted epidural steroid injection are rare. A 50-year-old man developed a headache and neck stiffness 2 days after a lumbar epidural steroid injection. Under the impression of aseptic meningitis, fluid and nonsteroidal anti-inflammatory drug therapy was started immediately after cerebrospinal fluid (CSF) sampling. The CSF was turbid, and revealed a white blood cell count, protein, glucose and pressure of $550/{\mu}l$ (98% lymphocyte), 107.9 mg/dl, 48 mg/dl (serum 113 mg/dl) and $17cmH_2O$, respectively. The CSF stain and culture, and antibody test and polymerase chain reaction for pathogens were negative. A computed tomography (CT) scan of the brain revealed no abnormality, and a chest roentgenogram and the results of the neurological examination were normal. Under the impression of aseptic meningitis, the condition was managed conservatively, without antibiotics. Seven days later, the clinical symptoms had improved, and the patient discharged.

수용액 분사에 의한 아이스 슬러리의 제조에 관한 실험적 연구 (An experimental study on ice slurry creation by injection of an aqueous solution)

  • 이용구;오철
    • 한국항해항만학회지
    • /
    • 제34권1호
    • /
    • pp.71-75
    • /
    • 2010
  • 아이스슬러리의 생성을 위하여 냉각평판에 작동수를 분사하는 실험을 수행하여 그에 대한 영향에 대하여 영향을 평가하였다. 실험에 사용된 에틸렌글리콜 수용액은 10~20wt%의 수용액을 사용하였다. 실험장치는 슬러리아이스 저장탱크, 브라인 탱크, 브라인 순환장치, 유량계 및 온도기록계로 구성되어 있다. 실험조건은 평균유속 1.0~2.0m/s, 냉각온도 $-17{\sim}-10^{\circ}C$의 조건 하에 실험을 수행하였다.