• 제목/요약/키워드: Fluid friction

검색결과 557건 처리시간 0.024초

Transient analysis of lubrication with a squeeze film effect due to the loading rate at the interface of a motor operated valve assembly in nuclear power plants

  • Jaehyung Kim;Sang Hyuk Lee;Sang Kyo Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.2905-2918
    • /
    • 2023
  • The valve assembly used in nuclear power plants is important safety-related equipment. In the new standard, the physical attributes are measured using a valve diagnosis test, which is used in the expansion to other non-tested valves using a quantitative test-basis methodology. With a motor-operated actuator, the state of stem's lubrication is related to physical attributes such as the stem factor and the friction coefficient. This study analyzed the numerical transient of fluid and solid lubrication with a squeeze film effect due to the loading rate on the stem and the stem nut using the experimental data. The differential equation that governs the motion mechanism of the stem and stem nut is established and analyzed. The flow rate, the fluid and the solid contact forces are calculated with the friction coefficient. Finally, we found that a change in the friction coefficient results from a change of the shear force in the solid contact mode during the interchange process between the solid contact mode and the fluid contact mode. The qualitative understanding of the squeeze film effect is expanded quantitatively for forces, thread surface distance, velocity, and acceleration, with consideration of the metal solid contact and fluid contact.

스털링기관 재생기내의 작동유체 유속 및 마찰저항 특성(I) - 작동유체 유속 특성 - (Velocity and Flow Friction Characteristic of Working Fluid in Stirling Engine Regenerator (I) - Velocity Characteristic of Working Fluid in Stirling Engine Regenerator -)

  • 김태한;조창래
    • Journal of Biosystems Engineering
    • /
    • 제32권6호
    • /
    • pp.389-394
    • /
    • 2007
  • The power output of the stirling engine is influenced by the regenerator effectiveness. The regenerator effectiveness is influenced by heat transfer and flow friction loss of the regenerator matrix. In this paper, in order to provide basic data for the design of the regenerator matrix, characteristics of working fluid velocities were investigated by a packed method of matrix in the oscillating flow as the same condition of operation in a Stirling engine. As matrices, two different wire screens were used. The results are summarized as follows; 1. When a regenerator is not filled with any wire screen, working fluid velocity of the oscillating flow shows 1.3 times faster than that of one directional flow. 2. When a regenerator is filled with the wire screen of No.50, working fluid velocity of the oscillating flow reveals 2.5 times faster than that of one directional flow. 3. When a regenerator is filled with the wire screen of No. 100, working fluid velocity of the oscillating flow shows 2 times faster than that of one directional flow, regardless of the number of packed wire screens. 4. Working fluid velocity is decreased wire the increase in number of meshes and packed wire screens.

환원분철을 이용한 마찰식 완충기 개발 (Friction Snubber Development Using Sponge Iron)

  • 김병삼
    • 한국소음진동공학회논문집
    • /
    • 제14권10호
    • /
    • pp.1021-1028
    • /
    • 2004
  • Developed friction snubbers changes the shock or vibration into a heat energy by mechanical friction. Snubber is divided into friction snubbers and hydraulic snubbers according to the operation types. However, hydraulic snubber has a lot of problems caused by temperature, humidity, radioactivity, and viscosity of hydraulic fluid. In these respects, to solve these problems, not only do friction snubber supplement lacks of hydraulic snubber but has also simpler structure than hydraulic snubber. In this paper, friction snubber used sponge iron by friction material is experimentally compared with general friction snubber In this results, the experiment verifies friction function and produce the manufacture condition for the effective friction snubber development.

이등변삼각형 단면을 갖는 파이프 내의 Pseudo-Plastic 유체유동에 대한 압력강하의 연구 (Investigation of Pressure Drop for a Pseudo-plastic Fluid Flow in Isosceles Triangle Pipes)

  • 이동렬
    • 동력기계공학회지
    • /
    • 제13권2호
    • /
    • pp.30-35
    • /
    • 2009
  • Numerical Calculations for dimensionless pressure drop (friction factor times Reynolds number) have been obtained for fully developed laminar flow of MPL(Modified Power Law) fluid in isosceles triangle pipes. The solutions are valid for Pseudoplastic fluids over a wide range from Newtonian behavior at low shear rates through transition region to power law behavior at higher shear rates. The analysis identified a dimensionless shear rate parameter which for a given set of operating conditions specifies where in the shear rate range a particular system is operating, i.e., Newtonian, transition or power law region. The numerical calculation data of the dimensionless pressure drop for the Newtonian and power law regions are compared with previously published asymptotic results presenting within 0.16 % in Newtonian region and 2.98 % in power law region.

  • PDF

도시철도 소음저감을 위한 MFI(Multi Fluid Injection) 시스템 개발 및 효과에 관한 연구 (A Study on the Development of MFI(Multi Fluid Injection) System and its Effect to Reduce the Noise of Subway)

  • 박종화;김대석;김희오;심재규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.446-454
    • /
    • 2011
  • The noise of the subway has become a social issue and includes very complex reasons. The friction between rail and train wheel is the most important reason of the noise. In this study, we developed MFI(Multi Fluid Injection) System which sprays the mixed fluid(water, anticorrosive and lubricant) on the rail when the train is approaching to reduce the friction. To verify the system's effect, we measured the internal and external noise of the running train. The measured and analyzed results show that MFI system reduce the noise of the running subway.

  • PDF

Tribological and rheological tests of core-shell typed carbonyl iron/polystyrene particle-based magnetorheological fluid

  • Zhang, Peng;Dong, Yu Zhen;Choi, Hyoung Jin;Lee, Chul-Hee
    • Journal of Industrial and Engineering Chemistry
    • /
    • 제68권
    • /
    • pp.342-349
    • /
    • 2018
  • Polystyrene (PS) was coated on carbonyl iron (CI) particles via dispersion polymerization to produce core-shell structured CI/PS particles and adopted as magnetorheological (MR) material. Two MR fluids were prepared by dispersing CI/PS and CI particles in silicone oil. Their MR and tribological properties were investigated using a rheometer and a reciprocating friction and wear tester, respectively. Experimental data showed that tribological properties of MR fluid based on CI/PS particles are significantly enhanced compared to those of CI based MR fluid. Sedimentation problem of CI/PS MR fluid was also expected to be improved due to relatively lower density of CI/PS particles.

모터구동 Flexible Wedge형 게이트밸브의 밸브 성능인자 Bounding Value에 대한 연구 (A Study on the Bounding Value of Valve Performance Parameters for Motor Operated Flexible Wedge Gate Valve)

  • 김대웅;유성연;박성근;이도환
    • 한국유체기계학회 논문집
    • /
    • 제10권5호
    • /
    • pp.46-53
    • /
    • 2007
  • Stem friction coefficient and valve factor are very important parameters for the evaluation of valve performance. In this study, the characteristics of stem friction coefficient and valve factor are analyzed, and thor bounding value is determined. The hydraulic testing is performed for many flexible wedge gate valves in the plant and statistical method is applied to the determination of bounding value. According to the results of this study, stem friction coefficient does not change much with differential pressure, and the bounding value of closing stroke is higher than that of opening stroke. The valve factor of valves with high differential pressure is higher than that of valves with medium differential pressure. It means valve factor is more sensitive to the differential pressure than the stem friction coefficient. Valve factor of the closing stroke is higher than that of opening stroke due to piston effect.

유동 해석을 통한 마그네슘 합금의 마찰교반용접 분석 연구 (Analysis of Friction Stir Welding Process of Mg alloy by Computational Fluid Dynamics)

  • 김무선;선승주;김정석
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.679-684
    • /
    • 2017
  • 마찰 교반 용접(Friction Stir Welding)은 금속 소재 대상으로 용접 툴과 용접 재료의 마찰열을 이용하여 재료 융점 이하의 온도에서 접합하는 용접 기법이다. 이번 연구에서는 금속 접합시 쓰이는 마찰 교반 용접 기법을 활용하여 마그네슘 합금(AZ31)을 용접할 때, 용접시 발생하는 용접 대상인 마그네슘 합금의 온도 및 속도 변화에 대해 유동 해석 기법을 활용하여 분석하였다. 분석을 위해 유동 해석 툴인 플루언트를 활용하여 모델링 및 해석을 진행하였다. 먼저 용접 소재는 온도에 따라 변하는 고점도 뉴턴 유체로 가정하였으며, 나선형 홈이 있는 용접 툴의 회전에 의한 회전 유동 발생을 모사하기 위해 회전 영역과 정지 영역으로 구분하여 모사하였다. 용접 툴과 용접 재료 사이의 인터페이스는 마찰 및 미끄러짐 경계조건을 부여하여 용접 툴로의 열전달 효과를 고려하였다. 위의 유동 해석 모델링을 통한 과도 해석 결과로부터 시간의 변화에 따른 용접 소재의 속도와 온도 특성을 파악할 수 있었다.

브레이크 게인 적응 휠 슬립 제어에 관한 연구 (A Study on Brake Gain Adaptive Wheel Slip Control)

  • 조준상;유승진;이교일
    • 유공압시스템학회논문집
    • /
    • 제4권1호
    • /
    • pp.13-17
    • /
    • 2007
  • The brake gain adaptive wheel slip controller for a vehicle is designed in this paper. The brake gain from braking pressure to braking torque defined by friction coefficient, friction area and effective friction radius is estimated by the adaptive law based on the wheel slip dynamics. And the wheel slip controller is designed based on the estimated brake gain. The robustness of the designed controller is analyzed using Lyapunov function and the convergence of brake gain is verified. Proposed wheel slip controller is verified via CarSim simulation with two kinds of desired wheel slip ratio.

  • PDF

래이디얼 피스톤 펌프의 효율 특성 연구 (A Characteristic Study of Efficiency in Radial Piston Pump)

  • 장윤석;천세민;임윤철
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2000년도 제31회 춘계학술대회
    • /
    • pp.106-113
    • /
    • 2000
  • A pump which is a fundamental device in a hydraulic system affects on overall system performance to a great deal. Such problems as leakage and solid friction loss become important in field applications, especially for the case of operation under high pressure and at high speed. So the research on this kind of subjects is necessary to improve the performance of hydraulic devices. A high pressure radial piston pump is analyzed here, which has a stationary cylinder block. It pumps hydraulic fluid by letting camring push a piston in a cylinder. Fluid leaks between the piston and cylinder so that it deteriorates the pump efficiency. Furthermore, the piston happens to touch the cylinder wall to increase the friction loss and wear. In this research, by means of FDM, volumetric, mechanical and overall efficiencies are observed by varying several design Parameters and operation conditions. Design values or their trends are presented to improve these efficiencies.

  • PDF