• Title/Summary/Keyword: Fluid feedback

Search Result 105, Processing Time 0.026 seconds

Design of a Robust Controller for a Watertight Damper Driving System (수밀댐퍼 구동장치의 강인제어에 관한 연구)

  • Han, Seung Hun;Jang, Ji Seong
    • Journal of Drive and Control
    • /
    • v.14 no.2
    • /
    • pp.45-51
    • /
    • 2017
  • Semi-submersible drilling rigs are offshore plants that perform functions such as ocean exploration for oil and gas acquisition, drilling and production, and storage and unloading of crude oil and gas. Semi-submersible drilling rigs use watertight dampers as emergency buoyancy holders. Since the watertight damper is an emergency shutoff device, it is mainly driven by a pneumatic driving system that can operate without a power supply. The pneumatic driving system has highly non-linear characteristics due to compressibility of air and external disturbance such as static and Coulomb friction. In this paper, a new control algorithm is proposed for a watertight damper driving system based on the sliding mode control with a disturbance observer. To evaluate control performance and robust stability of the designed controller, the control results were compared with the results obtained using the state feedback controller. As a result, it was confirmed that the pneumatic driving system for driving the watertight damper using the sliding mode controller with a disturbance observer can obtain excellent control performance against the parameter changes and the disturbance input.

Effects of geometric parameters of fluidic flow meter on flow rate (Fluidic 유량계의 기하학적 변수가 유동률에 미치는 영향)

  • Park, Gyeong-Am;Yun, Gi-Yeong;Yu, Seong-Yeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.12
    • /
    • pp.1608-1614
    • /
    • 1997
  • The fluidic flow meter detects the gas flow rate based on the principle of fluidic oscillation instead of the conventional displacement method. It has many merits: wide rangeability, no moving mechanical parts and calibration insensitive to physical properties of fluids. The width of nozzle, size of oscillation chamber, size of target, width of outlet are tested to obtain the effects of jet oscillation on the fluidic flow meter. As the width of nozzle is too wide compared with the size of target, jet oscillation is unstable. The oscillation frequency decreases as the distance between the nozzle and target increases and also as the distance between target and outlet contraction increases. Two different vortexes exist in the front and the rear regions of the target, and they affect the oscillation frequency. The outlet contraction is very important, because the feedback flow is generated by the blocking of the flow. As the width of outlet increases, the jet oscillation frequency decreases. The linearity of this tested flow meter is quite good.

Development of Wall Flow Sensor Using Micro Imaging Device (미세 영상 장치를 이용한 벽면 유동 센서 개발)

  • Lee, Seung Hwan;Kim, Byung Soo;Kim, Hyoung-Bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.12
    • /
    • pp.1217-1222
    • /
    • 2012
  • A wall flow sensor has been used for feedback flow control and wall shear stress measurement. In this study, we developed a new wall flow sensor by combining the PIV algorithm and the micro image sensor used in an optical mouse. The feasibility of the wall flow sensor was investigated by using simulated fluid flow experiments. Compared with the quadrature signal from imaging devices, the accuracy of the wall flow velocity measurement was improved and the dynamic range increased. In addition, the depth information of particles was also measured by using the defocusing imaging technique.

Automatic Flow Control and Network Monitoring of IV Injection (자동 IV 주사 유량 자동 제어 및 네트워크 모니터링)

  • Kim, Jin-Nam;Kwon, Won-Tae;Lee, Kang-Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.1
    • /
    • pp.161-166
    • /
    • 2012
  • Intravenous (IV) injection is widely used to supply Ringer solution directly into a vein in hospital. Generally, a passive injection method has been used, which causes the inconsistent flow rate of fluid and inappropriate control of injection time by a patient. It leads to an unnecessary nurse's overwork and decrement of IV injection's effect. To solve these problems, flow control infusion pumps have been developed. But because of relatively heavy weight and high price, its usage has been limited. In the present study, a new automatic IV injection system is developed. It is installed with a small pressing mechanism driven by a small electric motor to regulate the flow rate by pressing tube. Proportional integral derivative (PID) feedback control algorithm is applied to control the electric motor. The system is smaller in size and uses lower power than the existing commercial product. The newly developed system is also installed with networking capability, which enables monitoring the status of several automatic IV injection system at the same time.

Synchronous Control of an Asymmetrical Dual Redundant EHA (비대칭 이중화 EHA의 동기 제어)

  • Lee, Seong Ryeol;Hong, Yeh Sun
    • Journal of Drive and Control
    • /
    • v.13 no.2
    • /
    • pp.1-9
    • /
    • 2016
  • In this paper, an elementary force fighting problem was investigated. The problem is encountered when a double-rod type EHA(electro-hydrostatic actuator) is combined with a single-rod type EHA to build a redundant actuator system with synchronized motion. When the rod-side chambers of the two different types of EHAs have the same effective piston areas and are simultaneously pressurized by an external load, the two EHAs behave identically, sharing the external load equally. However, when the piston head-side chamber of the single rod type EHA, having a larger effective area than the rod-side chamber, is pressurized by the external load, an abnormal force fighting between the two EHAs occurs, unless their pump speeds are properly decoupled. In this study, the output drive forces of each EHA were obtained from the cylinder pressure signals and applied to the position control for each EHA to maintain the balance between their pump speeds. Adding minor force difference feedback loops to the position control, the force fighting phenomena could be eliminated and steady state synchronization errors were reduced. The power consumption of the pumps also could be remarkably reduced, avoiding unnecessarily high load pressures to the pumps.

Influence of Slashpipe Exercise on Symmetrical Contraction of Trunk Muscle in Normal Adults

  • Choi, Young In;Kim, Jung Sun;Kim, Shin Young
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.5
    • /
    • pp.298-303
    • /
    • 2019
  • Purpose: This study examined the effects of slashpipe exercise on reducing the thickness of the left and right external oblique, internal oblique, transverse abdominis, erector spinae, and multifidus muscles. Methods: A total of 29 healthy adult men and women were included in the study. They performed trunk flexion in the supine position and trunk extension in the prone position with a slashpipe and weight bar. The external oblique, internal oblique, and transverse abdominis muscles were measured in the supine position, while the erector spinae and multifidus muscles were measured in the prone position. The data were analyzed using the SPSS ver 21.0 statistical program. The difference in thickness between the right and left sides of the trunk muscle was analyzed by repeated measures analysis. The statistical significance level was set to p<0.05. Results: The results showed that the slashpipe exercise reduced significantly the difference in thickness of the oblique internus and erector spinae muscles compared to the weight bar exercise. Conclusion: The chaotic fluidity of the fluid filled inside the slashpipe could be used as sensory feedback information on body mal-alignment, which would have positively affected the symmetrical contraction of the trunk muscles as a trigger for self-correction. Therefore, it will have a useful effect not only on the health of the general public, but also on low back patients and athletes with muscle asymmetry.

The Effect of Problem-Based Learning for Patient Safety on Self-Leadership, Patient Safety Competencies, and Reflective Thinking of Nursing Students

  • Park, Jung-Ha;Yun, Ji-Ah;Park, Kyoung-Duck
    • International journal of advanced smart convergence
    • /
    • v.11 no.2
    • /
    • pp.194-204
    • /
    • 2022
  • This study is a one-group pretest-posttest design to evaluate the effect of problem-based learning (PBL) for patient safety on self-leadership, patient safety competencies, and reflective thinking of nursing students. The research was conducted from March 2 to April 15, 2022, in which 57 nursing students participated. PBL for patient safety was examined in a total of 8 sessions in the order of motivation, problem identification, task performance planning, problem-solving methods, summary and solution, presentation, and evaluation. The following topics of patient safety were selected for each team: nursing records, high-alert medication, medication error and intravenous fluid regulation, blood transfusion care, fall, bedsore, infection control, and pain management. We provided feedback on the learning process and outcomes of nursing students. According to the results, self-leadership showed a statistically significant improvement in self-expectations (t=2.60, p=0.01), goal setting (t=2.84, p<0.01), self-reward (t=3.32, p<0.01), and self-criticism (t=2.32, p=0.02). Patient safety competencies showed a statistically significant improvement in patient safety knowledge (t=13.05, p<0.001) and patient safety skills (t=4.87, p<0.001) but not in reflective thinking. The results prove that PBL for patient safety is an effective teaching-learning strategy to improve self-leadership and patient safety competencies. Future studies must develop and validate specific and long-term teaching-learning methods to improve reflective thinking.

Development and performance evaluation of Machine Control Kit mountable to general excavators (일반 굴삭기 장착 가능한 머신 컨트롤 키트 개발 및 성능 평가)

  • K.S. Lee;K.S. Kim;J.B. Jeong;E.S. Pak;J.I. Koh;J.J. Park;S.H. Joo
    • Journal of Drive and Control
    • /
    • v.21 no.1
    • /
    • pp.31-37
    • /
    • 2024
  • In this study, to prevent accidents in underground facilities during excavation, we developed a Lv.3 automated control system that can be configured as an electronic control system without changing the existing hydraulic system in a general excavator and utilized digital map information of underground facilities. We aimed to develop a strategy to prevent accidents caused by operator error. To implement this, a real-time excavator bucket end position recognition and control system was developed through angle measurement of the boom, arm, and bucket using an electronic joystick, RTK-GPS, and angle sensors. In addition, excavators are large, machine-based equipment, and it is difficult to control overshoot due to inertia with feedback control using position recognition information of the bucket tip. Therefore, feed-forward control is used to calculate the moving speed of the bucket tip in real-time to determine the target position. We developed a technology that can converge and verified the performance of the developed system through actual vehicle installation and field tests.

Influence of Smoking Cessation on Periodontal Biomarkers in Gingival Crevicular Fluid for 1 Year: A Case Study (1년간 금연이 미치는 치은열구액 내 치주염 바이오마커 변화: 사례연구)

  • Hwang, Soo-Jeong
    • Journal of dental hygiene science
    • /
    • v.14 no.4
    • /
    • pp.525-536
    • /
    • 2014
  • Although tobacco use has been known as one of the biggest risk factors on periodontal health, little is known about the effect of smoking cessation on it. The aim of this study was to investigate the change of concentration of matrix metalloproteinase (MMP)-8, MMP-9 and interleukin (IL)-$1{\beta}$ in gingival crevicular fluid (GCF) of 11 quit-smokers for 1 year after smoking cessation. Eleven male subjects to maintain quit-smoking for 1 year participated the oral examination, GCF and saliva collection without periodontal treatments at baseline, after 2 weeks, 2 months, 4 months, 6 months and 1 year. To confirm quit-smoking, nicotine and cotinine concentrations in saliva were measured by high performance liquid chromatography. MMP-8, MMP-9 and IL-$1{\beta}$ concentrations in GCF of upper anterior teeth area were measured by enzyme-linked immunosorbent assay. Change of MMP-8 in GCF during smoking cessation showed fluctuation with decrease (5 subjects) or increase (2 subjects) or maintenance tendency (4 subjects). Changes of MMP-9 were decrease (6 subjects), or increase (2 subjects), or maintenance (3 subjects). Change of IL-$1{\beta}$ also showed fluctuation with decrease (5 subjects) or increase (3 subjects) or maintenance tendency (3 subjects). The subjects with increase tendency had the relatively smaller amount concentration of MMP-8 and MMP-9 at the baseline. It was unclear smoking cessation without periodontal treatment could affect MMP-8, MMP-9, and IL-$1{\beta}$ in GCF. Fluctuation of periodontal biomarkers during smoking cessation might result from feedback interaction between environmental factors and periodontal cells.

Radiation Effect on NO, NOS and TGF-$\beta$ Expressions In Rat Lung (쥐의 폐에서 방사선이 Nitric Oxide (NO), Nitric Oxide Synthase (NO) 및 TGF- $\beta$의 발현에 미치는 영향)

  • Oh Young-Taek;Park Kwang-Joo;Kil Hoon-Jong;Ha Mahn Joon;Chun Mison;Kang Seung-Hee;Park Seong-Eun;Chang Sei-Kyung
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.321-328
    • /
    • 2000
  • Purpose :NOS2 induce NO Production and NO activate TGF-${\beta}$. The TGF-${\beta}$ is a inhibitor of NOS2. If this negative feedback mechanism operating in radiation pneumonitis model, NOS2 inhibitor may play a role in TGF-${\beta}$ suppression. We planned this study to evaluate the expression patterns of NO, NOS2 and TGF-${\beta}$ in vivo radiation pneumonitis model. Materials and Methods : Sixty sprague-Dawley rat were irradiated 5 Gy or 20 Gy. They were sacrificed 3, 7, 14, 28 and 56 days after irradiation. During sacrifice, we peformed broncho-alveolar lavage (BAL). The BAL fluids were centrifuged and supernatents were used for measure NO and TGF-${\beta}$, and the cells were used for RT-PCR. Results : After 5 Gy of radiation, NO in BAL fluid increased at 28 days in both lung and TGF-${\beta}$ in left lung at 56 days. NO increased in BAL fluid at 28 days in both lung after irradiation and TGF-${\beta}$ in right lung at 28-56 days after 20 Gy of radiation. After 5 Gy of radiation, NOS2 expression was increased in right lung at 14 days, in both lung at 28 days and in left lung at 56 days. TGF-${\beta}$ expression was reduced in both lung at 28 days and increased in left lung at 56 days. Conclusions :The Proposed feedback mechanism of NO, NOS2 and TGF-${\beta}$ was operated in vivo radiation pneumonitis model. At 56 days, however, NOS2 and TGF-${\beta}$ expressed concurrently in left lung after 5 Gy and in both lung after 20 Gy of radiation.

  • PDF