• 제목/요약/키워드: Fluid consumption

검색결과 261건 처리시간 0.028초

3.3kV(105A) COMPACT RACK TYPE 고압 인버터 시스템의 방열 성능 향상을 위한 열유동 해석 (THERMAL-FLUID ANALYSIS FOR COOLING PERFORMANCE IMPROVEMENT OF 3.3KV(105A) COMPACT RACK TYPE MEDIUM VOLTAGE INVERTER SYSTEM)

  • 김선영;김성대;유성열;유남규;김태범;홍찬욱;고한서
    • 한국전산유체공학회지
    • /
    • 제19권3호
    • /
    • pp.24-28
    • /
    • 2014
  • With ever rising concerns about saving of fossil fuel resource, there have been an increasing demand for use of energy more efficiently. The electric motor driven inverters can be a great help to improve energy efficiency. They are also used to control the motor speed to the actual need. Therefore the use of them can lead to reduce energy consumption. In particular, the medium voltage(MV) drive systems used for pumps, fans, steel rolling mills and tractions have widespread applications in the industry. They cover power ratings from 0.4MW to 40MW at the MV level of 2.3kV to 13.8kV. The majority of the installed MV drive systems however, are in the 1MW to 4MW range with voltage rating from 3.3kV to 6.6kV. But they are required to reduce size and weight like other power electronic equipments. In this paper, we studied on the 3.3kV(105A) compact rack type inverter system for improving the cooling efficiency. At first, we confirmed the tendency of temperature with computational simulation using ANSYS ICEPAK and actual experimental tests. And then we researched thermal performance improvement designs in order to reduce temperature of the transformer for the safe operation. It can reduce temperature of transformer that using pipe type flow guide in the system. As a result, we found out more efficient solution by thermal-fluid analysis.

저온 열원으로부터 최대 동력을 생산하기 위한 유기랭킨사이클(ORC)에 관한 연구 (Study on Organic Rankine Cycle (ORC) for Maximum Power Extraction from Low-Temperature Energy Source)

  • 김경훈;한철호;김기만
    • 한국태양에너지학회 논문집
    • /
    • 제31권3호
    • /
    • pp.73-79
    • /
    • 2011
  • ORC(organic Rankine cycle) has potential of reducing consumption of fossil fuels and has many favorable characteristics to exploit low-temperature heat sources. This work analyzes performance of ORC with superheating using low-temperature energy sources in the form of sensible energy. Maximum mass flow rate of a working fluid relative to that of a source fluid is considerd to extract maximum power from the sources. Working fluids of R134a, $iC_4H_{10}$ and $C_6C_6$, and source temperatures of $120^{\circ}C$, $200^{\circ}C$ and $300^{\circ}C$ are considered in this work. Results show that for a fixed source temperature thermal efficiency increases with evaporating temperaure, however net work per unit mass of source fluid has a maximum with respect to the evaporating temperature in the range of low source temperature. Results also show that the maximum power extraction is possible with R134a for the source temperature of $120^{\circ}C$, with $iC_4H_{10}$ for $200^{\circ}C$, and with $C_6C_6$ for $300^{\circ}C$.

Computational Fluid Dynamics를 이용한 부유식 새꼬막 채묘장치의 유동 특성에 관한 연구 (A study on the flow characteristics of floating seedling equipment using computational fluid dynamics)

  • 편용범;이경훈;최환석;이인태;김형호;이창제
    • 수산해양기술연구
    • /
    • 제59권2호
    • /
    • pp.164-171
    • /
    • 2023
  • This study analyzed the flow inside floating seedling equipment for Scapharca subcrenata. Due to the aging society of fishing villages, it is impossible to continuously input the labor force. Therefore, it is necessary to improve efficiency. Scapharca subcrenata has high per capita consumption. It serves as an important aquatic food resource. Scapharca subcrenata culture tends to be highly dependent on the natural environment. Production of Scapharca subcrenata is difficult to predict with low stability. In the past, manpower directly installed bamboo nets in mudflats. The seedling equipment devised in this study is a floating type and can be freely moved on the sea according to the prediction of Scapharca subcrenata generation. The flow around the floating seedling equipment was analyzed by numerical analysis. The physical phenomena of the flow around the net inside the floating seedling equipment were visualized. As a result, the space between the floating seedling equipment and the bottom net and the space between the net groups showed a lower flow rate than the inlet flow rate. It is expected that the low flow rate of the floating seedling equipment will have a positive effect on the attachment of Scapharca subcrenata.

시판되는 각종 음료수내 불소 함량과 소아의 불소섭취에 관한 연구 (A STUDY ON THE FLUORIDE CONTENT OF THE COMMERCIALLY AVAILABLE BEVERAGES AND THE FLUORIDE INTAKE OF CHILDREN)

  • 이미나;이상훈;김종철
    • 대한소아치과학회지
    • /
    • 제24권1호
    • /
    • pp.125-138
    • /
    • 1997
  • Along with recent economic prosperity, the consumption of commercially available beverages has increased dramatically. Beverages on the market are replacing tap water and constituting an increasing large proportion of the total daily fluoride intake. If such changes in the source of fluid intake are not taken into consideration, effective fluoride intake would become difficult in the fluoridated area while there would be confusion as to the basis for proper fluoride supplement prescription in the nonfluoridated area. So, dietary consultation is recommended for every pediatric patient. This study was conducted to provide the reference for dietary consultations on the subject of fluoride supplement using 72 beverages on the market. The fluoride content was measured and the fluoride intake from each age groups was calculated using fluoride ion specific electrode and HMDS-microdiffusion technique. 1. The average fluoride concentration of the 72 beverages was $0.23{\pm}0.10ppm$, from 0.0106ppm to 2.2050ppm. 2. Natural fruit juices, diluted fruit juices, carbonated beverages and mixed beverages showed average fluoride concentration of $0.15{\pm}0.66ppm$, $0.09{\pm}0.11ppm$, $0.15{\pm}0.23ppm$, $0.50{\pm}0.66ppm$, respectively. There were significant differrence between diluted friut juice drinks and mixed beverage, and between the carbonated beverages and mixed beverges(p<0.05). 3. Using available data on the daily total consumption of beverages and the relative consumption of beverages on the market according to age, daily fluoride intake for various age groups was calculated. According to the results, 2 to 3 year-old children need 0.13mgF/day, those between 4 and 6 year-old need 0.15mgF/day, and those between 7 and 10 year-old need 0.17mgF/day.

  • PDF

오일 미스트 포집을 위한 저전력 소비형 2단 전기집진기의 집진효율에 대한 연구 (A study on particle collection efficiency of a low power consumption two-stage electrostatic precipitator for oil mists collection)

  • 송치성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권7호
    • /
    • pp.834-843
    • /
    • 2014
  • 본 연구에서는 마이크로 탄소 브러쉬 하전부와 평판형 금속 집진부로 구성된 저전력 소비형 2단형 전기집진기를 개발하였고, 특히 인체 위해성이 높은 $0.3{\mu}m$급의 미세한 오일 미스트에 대한 인가전압 및 소비전력별 집진효율 특성을 실험연구를 통해 고찰하였다. 하전부의 인가전압에 따른 단위 입자당 하전율과 입경별 집진효율을 측정함과 동시에 이론에 근거한 계산값과 비교해 보았으며, 9 주 동안의 장시간 운전을 통해 지속적으로 포집된 오일 미스트에 의한 전기집진기의 성능을 열유체역학적인 관점에서 변화를 조사하였다.

Effects of Protein Kinase C Modulation on Hepatic Hemodynamics and Glucoregulation

  • Lee, Joong-Woo;Kong, In-Deok;Park, Kyu-Sang;Chung, Hae-Sook;Filkins, James P.
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제3권6호
    • /
    • pp.571-578
    • /
    • 1999
  • This study evaluated the effects of PKC activation using phorbol 12-myristate 13-acetate (PMA) and PKC inhibition using the isoquinoline sulfomide derivative H-7 on hemodynamics and glucoregulation in the isolated perfused rat liver. Livers were isolated from fed male Holtzman rats and perfused with Krebs Ringer bicarbonate solution under a constant flow of 50 ml/min at $35^{\circ}C.$ Portal vein pressure, glucose and lactate concentrations in the medium and oxygen consumption rates were continuously monitored by a Grass polygraph, YSI glucose and lactate monitors, and a YSI oxygen monitor, respectively. PMA at concentration of 2 to 200 nM increased the portal vein pressure, glucose and lactate production, but decreased oxygen consumption rate in a dose-dependent fashion. H-7 $(200\;{\mu}M)$ attenuated PMA (50 nM)-induced vasoconstriction $(15.1{\pm}1.36\;vs\;10.56{\pm}1.17\;mmHg),$ glucose production rate $(91.3{\pm}6.15\;vs\;71.8{\pm}2.50\;{\mu}moles/g/hr),$ lactate production rate $(72.4{\pm}6.82\;vs\;53.6{\pm}4.82\;{\mu}moles/g/hr)$ and oxygen consumption rate $(33.7{\pm}1.41\;vs\;27.9{\pm}1.75\;{\mu}l/g/min).$ The effects of PMA were blocked either by addition of verapamil $(9\;{\mu}M)$ or perfusion with $Ca^{2+}-free$ KRB. These results suggest that the hemodynamic and glucoregulatory changes in the perfused rat liver are mediated by protein kinase C activation and require $Ca^{2+}$ influx from the extracellular fluid.

  • PDF

대복, Gomphina veneriformis 아가미의 조직학적 변화와 산소소비율에 미치는 TBTCl의 독성 (Tributyltin chloride (TBTCl) toxicity on the oxygen consumption rate and histological changes of gill in the equilateral venus, Gomphina veneriformis (Bivalvia: Veneridae))

  • 박정준;이정식
    • 한국어병학회지
    • /
    • 제21권1호
    • /
    • pp.67-79
    • /
    • 2008
  • This study was conducted to find out biological response of bivalves exposed to tributyltin chloride(TBTCl). The results of the study confirmed that TBTCl induce the reduction of oxygen consumption rateand histopathological feature in the gill structure of equilateral venus, Gomphina veneriformis. The experi-mental groups consisted of a control and 3 TBTCl exposure groups (0.4, 0.6 and 0.8 yg TBTCl L') and theexperimental period was 36 weeks. For histological analysis, gill tissues were fixed in Bouin's fluid andthen stained H-E stain, AB-PAS (PH 2.5) reaction and Masson's trichrome stain after having serially sec-tioned the tissue by paraffin method at thickness of 4-6 (an. The oxygen consumption rate was not signifi-cantly different between the control and exposure groups at 4 weeks, but in all exposure groups at 28 weeks,it was significantly different to the control. Gill of G. veneriformis had demibranch that attached two sheetsof lamellae and a lamella was composed of numerous filaments, numbering 25 on average. The frontal fila-ment zone had three types of cilia; frontal, latero-frontal and lateral depending on locations while the lateralcilia were the longest and largest in number. The mucous cells observed in filaments were more abundant in(542c) in AB-PAS (PH 2.5) reaction. Gill exposed to TBTCl was extended hemolymph sinus and increased hemocytes at 4 weeks, and then it showed increases of mucous cells and partially disappearance of frontalcilia. In the group of 0.8 yg TBTCl L' at 12 weeks, hypertrophy of frontal and latero-frontal epithelia wasobserved. Also it observed m decrease of mucous cell containing weekly acid mucosubstance and appearedpartially destruction muscle fiber bundle, In the groups of 0.4 and 0.6 ug TBTCl L' at 36 weeks, it appearedpartially modification of epithelia and in 0.8 us TBTCl L' group, observed filaments that come out chiti-nous rod from disappearance of frontal and latero-frontal epithelia.

Synthetic Jet 마이크로 에어펌프의 개발 (Development of Synthetic Jet Micro Air Pump)

  • 최종필;김광수;서영호;구보성;장재혁;김병희
    • 소성∙가공
    • /
    • 제17권8호
    • /
    • pp.594-599
    • /
    • 2008
  • This paper presents a micro air pump based on the synthetic jet to supply reactant at the cathode side for micro fuel cells. The synthetic jet is a zero mass flux device that converts electrical energy into the momentum. The synthetic jet actuation is usually generated by a traditional PZT-driven actuator, which consists of a small cylindrical cavity, orifices and PZT diaphragms. Therefore, it is very important that the design parameters are optimized because of the simple configuration. To design the synthetic jet micro air pump, a numerical analysis has been conducted for flow characteristics with respect to various geometries. From results of numerical analysis, the micro air pump has been fabricated by the PDMS replication process. The most important design factors of the micro air pump in micro fuel cells are the small size and low power consumption. To satisfy the design targets, we used SP4423 micro chip that is high voltage output DC-AC converter to control the PZT. The SP4423 micro chips can operate from $2.2{\sim}6V$ power supply(or battery) and is capable of supplying up to 200V signals. So it is possible to make small size controller and low power consumption under 0.1W. The size of micro air pump was $16{\times}13{\times}3mm^3$ and the performance test was conducted. With a voltage of 3V at 800Hz, the air pump's flow rate was 2.4cc/min and its power consumption was only 0.15W.

An iterative boundary element method for a wing-in-ground effect

  • Kinaci, Omer Kemal
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제6권2호
    • /
    • pp.282-296
    • /
    • 2014
  • In this paper, an iterative boundary element method (IBEM) was proposed to solve for a wing-in-ground (WIG) effect. IBEM is a fast and accurate method used in many different fields of engineering and in this work; it is applied to a fluid flow problem assessing a wing in ground proximity. The theory and the developed code are validated first with other methods and the obtained results with the proposed method are found to be encouraging. Then, time consumptions of the direct and iterative methods were contrasted to evaluate the efficiency of IBEM. It is found out that IBEM dominates direct BEM in terms of time consumption in all trials. The iterative method seems very useful for quick assessment of a wing in ground proximity condition. After all, a NACA6409 wing section in ground vicinity is solved with IBEM to evaluate the WIG effect.

Development of the Pneumatic Servo Valve

  • Kim, Dong-Soo;Choi, Byung-Oh;Kim, Kwang-Young;Lee, Won-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1146-1151
    • /
    • 2003
  • Pneumatic servo valve is an electro-mechanical device which change electric signals to a proper pneumatic signals, that is, flowrate and pressure. In this study, a pneumatic servo valve was designed and each simulation was conducted on any variation in the flowrate depending upon the magnetic force of the linear force motor and the displacement of the spool. And permanent magnet was used as a material for the plunger of the servo valve. Thereby, a low electrical power consumption type coil was desinged. And a modeling for the coil design was conducted by using the magnetic circuit. also, the feasibility of the modeling was verified by using a commercial magnetic field analysis program. The designed and fabrication of the spool and sleeve, position sensor, servo controller and the dynamic characteristic verified by the experiment.

  • PDF