• Title/Summary/Keyword: Fluid Flow System

Search Result 2,221, Processing Time 0.032 seconds

Study on the Atomization Characteristics of a Counter-swirling Two-phase Atomizer with Variations of Swirl angle (역선회 이류체 미립화기의 선회각 변화에 따른 미립화 특성연구)

  • Kim, N.H.;Lee, S.G.;Ha, M.H.;Rho, B.J.;Kang, S.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.125-130
    • /
    • 2001
  • Experimental and analytical researches have been conducted on the twin-fluid atomizers for better droplet breakup during the past decades. But, the studies on the disintegration mechanism still present a great challenge to understand the drop behavior and breakup structure. In an effort to describe the aerodynamic behavior of the sprays issuing from the internal mixing counter-swirling nozzle, the spatial distribution of axial (U) radial (V) and tangential (W) components of droplet velocities are investigated across the radial distance at several axial locations of Z=30, 50, 80, 120 and 170mm, respectively. Experiments were conducted for the liquid flow rates which was kept constant at 7.95 g/s and the air injection pressures were varied from 20 kPa to 140 kPa. Counter-swirling internal mixing nozzles manufactured at angles of $15^{\circ},\;30^{\circ},\;45^{\circ}$ and $60^{\circ}$ the central axis with axi-symmetric tangential-drilled holes was considered. The distributions of velocities and turbulence intensities are comparatively analyzed. PDPA is installed to specify spray flows, which have been conducted along the axial downstream distance from the nozzle exit. Ten thousand of sampling data was collected at each point with time limits of 30 second. 3-D automatic traversing system is used to control the exact measurement. It is observed that the sprays with all swirl angle have the maximum SMD for on air injection pressure of 20 kPa and 140 kPa with centerline, respectively. The nozzle with swirl angle of $60^{\circ}$ has vest performance.

  • PDF

High Resolution Borehole Acoustic Scanner (Televiewer) (고분해능 텔레뷰어 검층기법의 기능)

  • ;Schepers,R
    • The Journal of Engineering Geology
    • /
    • v.5 no.3
    • /
    • pp.277-288
    • /
    • 1995
  • Fracture detection has always been very attractive to the log, because it is important in many of our prospecting activities, e.g. in understanding the underground rock formation and also the fluid flow as a high permeability path. This paper demonstrates the use of high resolution borehole acoustic scanner for the detection of fractures. The tool, known as Televiewer, is the first acoustic borehole imaging system to use a focussed beam. The acoustic beams generated by a single transducer are sent toward the borehole wall, scanning the wall in a tight helix as the tool moves along the borehole. The amplitudes and travel times of the reflected signals are then measured, which produces the corresponding images. The highly resolved amplitude image allows to recognize various size of fractures and in addition to derive the rock strength from the image. Meanwhile, the travel time image itself can be directly converted to a precise caliper image, providing detailed information of deviations of the borehole shape. It also allows correction of and explanations for amplitude variations. Field measurements were carried Out at the Cheongyang study sites in Korea to illustrate the efficiency of the televiewer log.

  • PDF

Parametric Study of 2.5 kW Class Propeller Type Micro Hydraulic Turbine (2.5 kW 급 프로펠러형 마이크로 수차 매개변수 연구)

  • MA, SANG-BUM;KIM, SUNG;CHOI, YOUNG-SEOK;CHA, DONG-AN;KIM, JIN-HYUK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.4
    • /
    • pp.387-394
    • /
    • 2020
  • A parametric study of a 2.5 kW class propeller type micro hydraulic turbine was performed. In order to analyze the internal flow characteristics in the hydraulic turbine, three dimensional Reynolds-averaged Navier-Stokes equations with shear stress transport turbulence model were used and the hexahedral grid system was used to construct computational domain. To secure the reliability of the numerical analysis, the grid dependency test was performed using the grid convergence index method based on the Richardson extrapolation, and the grid dependency was removed when about 1.7 million nodes were used. For the parametric study, the axial distance at shroud span (L) between the inlet guide vane and the runner, and the inlet and outlet blade angles (β1, β2) of the runner were selected as the geometric parameters. The inlet and outlet angles of the runner were defined in the 3 spans from the hub to tip, and a total of 7 geometric parameters were investigated. It was confirmed that the outlet angles of the runner had the most sensitive effect on the power and efficiency of the micro hydraulic turbine.

Study on copper end-tab shape for maximum heat discharging performance (방열 성능 향상을 위한 구리 엔드 탭의 최적형상 연구)

  • Choi, Yeou-Myeong;Choi, Yoon-Hwan;Cho, Sang-Myung;Park, Jung-Hyun;Lee, Yeon-Won
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • When implementing butt joint welding of two plates, it is useful to attach end-tabs made of a metal with high heat conductivity (e.g., copper) at the front and back sides of the welded plates to prevent the bead from rolling down and prevent defects that may occur at the tips of the weld zone. In this study, the fin shape, which is known to have good heat discharging characteristics by natural convection, has been applied to enhance the cooling performance of the end-tab. From both experiment and numerical analysis, it was confirmed that end-tabs with fin-shaped holes have better heat discharging performance than end-tabs without holes. Through thermal and fluid flow analysis, the cooling rates of end-tabs with different hole shapes were estimated in order to figure out characteristics of shape factor that are important for the heat discharging performance. As a result, we found that the structure including vertical fins with optimal fin gap was the best-performing shape.

Heat transfer analysis of closed-loop vertical ground heat exchangers using 3-D fluid flow and heat transfer numerical model (3차원 열유체 수치해석을 통한 현장 시공된 수직 밀폐형 지중열교환기의 열전달 거동 평가)

  • Park, Moon-Seo;Lee, Chul-Ho;Min, Sun-Hong;Kang, Shin-Hyung;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.800-807
    • /
    • 2010
  • In this study, a series of numerical analyses has been performed in order to evaluate the performance of a full-scale closed-loop vertical ground heat exchanger constructed in Wonju. The circulation pipe HDPE, borehole and surrounding ground were modeled using FLUENT, a finite-volume method (FVM) program, for analyzing the heat transfer process of the system. Two user-defined functions (UDFs) accounting for the difference in the temperatures of the circulating inflow and outflow water and the change of the surrounding ground temperature with depth were adopted in the FLUENT model. The thermal properties of materials estimated in laboratory were used in the numerical analyses to compare the thermal efficiency of the cement grout with that of the bentonite grout used in the construction. The results of the simulation provide a verification of the in situ thermal response test data. The numerical model with the ground thermal conductivity of 4W/mK yielded the simulation result closer to the in-situ thermal response test than with the ground thermal conductivity of 3W/mK. From the results of the numerical analyses, the effective thermal conductivities of the cement and bentonite grouts were obtained to be 3.32W/mK and 2.99 W/mK, respectively.

  • PDF

Improvement of Mechanical Properties of UV-curable Resin for High-aspect Ratio Microstructures Fabricated in Microstereolithography (마이크로광조형에서 고 세장비 구조물 집적화 가공을 위한 UV 경화성 수지의 물성 개선)

  • Lee, Su-Do;Choi, Jae-Won;Park, In-Beak;Ha, Chang-Sik;Lee, Seok-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.12
    • /
    • pp.119-127
    • /
    • 2007
  • Recently, microstructures fabricated using microstereolithography technology have been used in the biological, medical and mechanical fields. Microstereolithography can fabricate real 3D microstructures with fine features, although there is presently a limited number of materials available for use in the process. Deformation of the fine features on a fabricated microstructure remains a critical issue for successful part fabrication, and part deformation can occur during rinsing or during fabrication as a result of fluid flow forces that occur during movement of mechanical parts of the system. Deformation can result in failure to fabricate a particular feature by breaking the feature completely, spatial deflection of the feature, or attaching the feature to neighboring microstructures. To improve mechanical strength of fabricated microstructures, a clay nanocomposite can be used. In particular, a high-aspect ratio microstructure can be fabricated without distortion using photocurable liquid resin containing a clay nanocomposite. In this paper, a clay nanocomposite was blended with a photocurable liquid resin to solve the deformation problem that occurs during fabrication and rinsing. An optimal mixture ratio of a clay nanocomposite was found through tensile testing and the minimal allowable distance between microstructures was found through fabrication experimentation. Finally, using these results, high-aspect ratio microstructures were fabricated using a clay nanocomposite resin without distortion.

An Experimental Study on the Thermal Performance of Air Filled Thermal Diode (공기를 작동 유체로 하는 열다이오드의 열성능에 관한 실험적 연구)

  • Pak, Ee-Tong;Jang, Young-Geun;Hwang, In-Ju
    • Solar Energy
    • /
    • v.17 no.2
    • /
    • pp.35-42
    • /
    • 1997
  • Thermal diode is a device which allows heat to be transferred in one direction by convection due to difference of density of fluid, and blocks heat flow in the opposite direction. Vertical plate for heat collection and radiation are of utility for design of thermal diode. It was considered the transient and steady state of air filled thermal diode with guide vane which combined rectangular and parallelogrammic shape enclosures. $Gr^*$ was kept constantly on $1.11{\times}10^{10}{\sim}1.4{\times}10^{10}$ and error range was ${\pm}3%$ during the experiment. Nu was examined when inclined angle are $15^{\cir\c}\;and\;45^{\circ}$ and, also the experiments was carried out with and without guide vane as well. Specially, Nu was linearly increased due to increase of $Gr^*$, and the effect of guide vane and dimensionless channel depth was sensitive. Developed state of temperature began at dimensionless time $0.5{\sim}0.6$ due to variation of inclined angle, which is characteristic of system.

  • PDF

Sensitivity Analysis of Design Parameters of Air Tightness in Underground Lined Rock Cavern (LRC) for Compressed Air Energy Storage (CAES) (복공식 지하 압축공기에너지 저장공동 기밀시스템 설계변수의 민감도 해석)

  • Kim, Hyung-Mok;Rutqvist, Jonny;Ryu, Dong-Woo;Sun-Woo, Choon;Song, Won-Kyong
    • Tunnel and Underground Space
    • /
    • v.21 no.4
    • /
    • pp.287-296
    • /
    • 2011
  • We performed a numerical modeling study of thermodynamic and multiphase fluid flow processes associated with underground compressed air energy storage (CAES) in a lined rock cavern (LRC). We investigated air tightness performance by calculating air leakage rate of the underground storage cavern with concrete linings at a comparatively shallow depth of 100 m. Our air-mass balance analysis showed that the key parameter to assure the long-term air tightness of such a system was the permeability of both concrete linings and surrounding rock mass. It was noted that concrete linings with a permeability of less than $1.0{\times}10^{-18}\;m^2$ would result in an acceptable air leakage rate of less than 1% with the operational pressure range between 5 and 8 MPa. We also found that air leakage could be effectively prevented and the air tightness performance of underground lined rock cavern is enhanced if the concrete lining is kept at a higher moisture content.

3D Numerical Study of Horizontal Falling Film Evaporator in Multi Effect Distillation (MED) Plant (MED 담수기내 수평관 강하막식 증발기의 3D 수치해석적 연구)

  • Kim, Soo Jae;Je, Junho;Kim, Moo Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.513-522
    • /
    • 2013
  • In the present work, a numerical study of a horizontal falling film evaporator in a multi-effect distillation (MED) plant is performed. Tube bundles in the evaporator are described as porous media, and a volume-averaged method is applied. To calculate the fluid flow and phase change in the evaporator due to heat transfer in the system, FLUENT and user-defined functions (UDF) are used. To observe the performance of the evaporator under different operational conditions, tests are conducted for a steam mass flux ranging from 0.5 to 2.5 $kg/m^2s$ in the horizontal tube, for mass fraction of the noncondensable gas in the tube inlet ranging from 0% to 1%, and for film Reynolds numbers ranging from 100 to 1,000 for the falling film. The evaporation rate increases with the steam mass flux and Reynolds number. In contrast, the evaporation rate decreases by 0.87% with a 1% increase in the mass fraction of the noncondensable gas in the tube.

Fluid/Particulate Heat Transfer Coefficient in a Continuous Flow Cooking System (연속살균장치에서의 액상/고상 식품간의 대류열전달계수 예측)

  • Choe, J.S.;Hong, J.H.;Koh, H.K.
    • Journal of Biosystems Engineering
    • /
    • v.29 no.2
    • /
    • pp.141-150
    • /
    • 2004
  • 우리가 소비하는 가공 식품은 위생상 안전하도록 살균처리가 이루어진다. 식품 내에 존재할 수 있는 유해 세균은 일정 살균온도에서 살균에 필요한 시간 동안 노출되면 사멸하며, 일반적으로 살균온도가 높을수록 살균에 필요한 시간은 단축된다. 연속살균장치는 혼합 및 저장탱크에 담겨진 식품을 점프로 이동시키면서 가열 열교환기에서 살균온도로 가열하고 단열관을 거치는 동안 살균온도를 유지시켜 살균을 완료한다. 또한 살균된 식품은 냉각용 열교환기에서 상온으로 냉각되며 이 과정에서 회수되는 열은 저장탱크에서 유입되는 식품의 예열에 사용되어 에너지 효율을 제고하는데 사용되기도 한다. 이와 같이 관을 이동하면서 가열되는 살균장치는 기존의 배치식 살균방법에 비하여 균일하게 가열이 이루어지므로 130C의 고온으로 살균할 수 있어서 살균에 필요한 시간을 수초에서 수십초 정도로 단축시킬 수가 있고 그에 따라 열손상을 크게 줄일 수 있다. 또한, 상온으로 냉각된 식품을 포장함으로써 저렴한 가격의 포장용기를 사용할 수 있고 상온에서 저장할 수 있으므로 저장비용이 저렴한 장점이 있다. 그러나, 가공식품에 고기나 야채와 같은 고체 상태의 식품이 함유된 경우에는 액상 식품이 열 교환기에서 순간 가열되며, 고상 식품은 액상식품과의 대류에 의한 열전달로 가열된다. 이 과정에서 고상식품은 이동관 내벽이나 다른 고상식품과 부딪치거나 회전하면서 이동관 내부에서 자유롭게 운동하게 된다. 이 과정에서 액상식품과의 상대이동 속도가 발생하여 이것이 대류열전달에 영향을 미치게 된다. 이 상대이동속도에 따른 대류 열전달계수는 고상식품의 내부온도 결정에 사용되는 연속살균장치의 중요한 설계인자이다. 대류열전달계수는 연속살균장치에서 자유로이 이동하는 고상식품의 중심부의 온도를 측정하여 결정할 수 있으나 이는 현실적으로 어렵다. 따라서 본 연구에서는 고정된 고상식품에 액상식품을 이동시켜 상대속도를 재현하고 액상식품의 온도와 고상식품의 중심온도를 측정하는 장치를 개발하였으며, 각 상대속도와 액상식품의 점도 별 대류열전달계수를 결정하는 프로그램을 유한차분법을 이용하여 개발하였다. 이 장치를 분당 15, 30, 40 리터의 유량에서 유체의 점도를 0에서 15 centipoise 사이의 세 수준에서 정육면체 소고기를 모델 고상식품으로 내부 온도분포를 측정하였으며, 유한차분법 프로그램으로 대류열전달계수를 결정하였다. 대류열전달계수는 792에서 2,107 W/m$^2$로 분석되었다. 대류열전달 계수는 액상식품과의 상대속도가 증가함에 따라서 증가하였고, 점도가 증가함에 따라서는 감소하였다.