• Title/Summary/Keyword: Fluid Distribution

Search Result 1,696, Processing Time 0.027 seconds

Influence of Impeller Outlet Angles in Pump Flow Patterns and Characteristics (임펠러 출구각이 펌프 내부유동 및 특성에 미치는 영향)

  • Lee, Sun-ki
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.1 s.6
    • /
    • pp.28-36
    • /
    • 2000
  • For the improvement of the pump characteristics in the partial capacity range, it must be verified that the influence of the impeller design factor on the internal flows and the influence of the impeller internal flows on the pump characteristics. In this paper, in order to understand the influence of outlet angles on flow conditions and characteristics of a mixed flow pump, experiments were carried out for four kinds of impeller, which have the same inlet angle distributions and meridional section shapes. Results shown that separation and stall in the partial capacity range were enlarged by the outlet angles. The relationship between the separation and the stall at the impeller and the discharge flow conditions were clarified.

  • PDF

A study on unsteady conjugate forced convection-conduction heat transfer from a plate fin (평판핀에서의 강제대류-전도 과도 복합열전달에 관한 연구)

  • 조진호;이상균
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.11 no.1
    • /
    • pp.20-30
    • /
    • 1989
  • The unsteady conjugate forced convection-conduction heat transfer from a plate fin is numerically studied. The external forced flow is steady but the temperature of the fin base is an exponential change with time. Therefore, the unsteady energy equations of the fluid and the fin are solved simultaneously under the conditions of equality in heat flux and temperature at the fluid-fin interface at every instant of time. Numerical results are given for various quantities of interest including the local heat transfer coefficient, the local heat flux, the total heat transfer rate and the temperature distribution of fin under the effects of the convection-conduction parameter and the ratio of thermal diffusivities. The results of the present numerical solution have been compared with those of the conventional fin theory.

  • PDF

Flow Characteristics of Centrifugal Impeller Exit under Rotating Stall (선회실속하의 원심 임펠러 출구 유동 특성)

  • Shin, You-Hwan;Kim, Kwang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.2 s.3
    • /
    • pp.5-12
    • /
    • 1999
  • This study presents the measured unsteady flctuation of impeller discharge flow for a centrifugal compressor in an unstable operating region. The characteristics of the blade-to-blade flow at rotating stall onset were investigated by measuring unsteady velocity fluctuations at several different diffuser axial distances using a hot wire anemometer. The flow characteristics in terms of the radial and tangential velocity components and the flow angle distribution at the impeller exit were analyzed using phase-locked ensemble averaging techniques. As a result, increase or decrease of the radial velocity component during the rotating stall is dominated by that of the suction side. The radial velocity distributions show the opposite trends in the regions where the radial velocity during rotating stall onset increases and decreases.

  • PDF

Numerical Analysis for a Supersonic Turbine having Square Section Nozzles (사각 단면 노즐을 장착한 초음속 터빈유동장의 수치해석)

  • Park, Pyun-Goo;Jeong, Eun-Hwan;Kim, Jin-Han
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.1
    • /
    • pp.55-60
    • /
    • 2011
  • Numerical analyses of a turbine redesigned to achieving the weight reduction by equipping square nozzles and the original turbine have been conducted and the results have been compared. The results show that the turbine with square section nozzles has more even flow distribution at the first row rotor inlet and less inactive areas but the loss induced by wake is increased. Despite the wake loss, the newly designed turbine shows better performance than the original one. It has also been found that the turbine performance can be improved by reshaping its stator and second row rotor.

Study on the growth of vapor bubble in devolatilization of polymers

  • Kim, Chongyoup
    • Korea-Australia Rheology Journal
    • /
    • v.11 no.3
    • /
    • pp.247-253
    • /
    • 1999
  • The growth of a spherical vapor bubble contained in a large body of upper convected Maxwell fluid is theoretically analyzed under the devolatilization condition of polymer by using a Galerkin FEM in the Lagrangian frame. Using the finite element technique, a fully explicit numerical scheme is developed both for the calculation of pressure distribution and for the tracking of bubble surface. Oscillatory behavior in bubble radius is observed during growth and the oscillatory behavior is found to be due to the interaction of mass transfer resistance and elasticity. It is found that the elasticity of fluid accelerates the growth and removal of volatile component. It is also found that the bubble growth in the devolatilization of polymers is affected by both mass transfer resistance and viscoelasticity of fluids.

  • PDF

A NUMERICAL INVESTIGATION OF INDOOR AIR QUALITY WITH CFD

  • Sin Vai Kuong;Sun Ho I
    • Journal of computational fluids engineering
    • /
    • v.10 no.1
    • /
    • pp.87-93
    • /
    • 2005
  • Macao, a city with three sides bounded by water, is hot and humid in weather in more than six months of a year. This uncomfortable weather induces the frequency of operating air-conditioners. Choice of location for installation of air-conditioner in a building will affect the performance of cooling effect and thermal comfort on the occupants, which in turn will affect the indoor air quality (IAQ) of the building. In the paper, investigation of distribution on carbon dioxide, room air temperature and velocity, as well as air diffusion performance index (ADPI) of a single bedroom in Macao is studied by using the computational fluid dynamics (CFD) software FLOVENT 3.2. Simulations of locating the air-conditioner at 4 different walls will be done and comparisons and analyses of the results will be performed to decide a proper location for the air-conditioner for obtaining good thermal comfort.

A Study on the Transient Motion Analysis for the Liquid Balinced Washing Machine (액체밸런서를 고려한 세탁기의 과도응답 특성에 관한 연구)

  • 이동익;오재응
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.1
    • /
    • pp.1-13
    • /
    • 1995
  • In order to investigate the effect of liquid balancer in washing machine, we identify the vibration characteristics of suspension system of washing machine and formulate the 4 D. O. F. system dynamic equations. As the washing machine rotates higher speed, it is emphasized to reduce the ecentric force due to unbalanced mass. Nowadays, the most effective cancelling method of eccentric force is known as the usage of liquid balancer. To determine the liquid distribution in liquid balancer, the fluid statics is considered. The system dynamic equations are solved by Runge-Kutta method and represent the good characteristics of real washing machine in X-Y plane. The accuracy of the numerical solution was examined by experiments. The simulation results show that the unbalanced mass has so much influence on vibration magnitude and the rotating shape of spin-basket. But the effect of mass reduction due to the dehydration of the spin-basket has little influence on transient vibration.

A Study on the Characteristics of Flow in the Metal Touch Ball Valve according to the Opening degree (볼밸브의 개폐각도에 따른 유동특성 분석)

  • An, Tae-Won;Han, Geun-Jo;Han, Dong-Seop;Lee, Seong-Wook
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.175-178
    • /
    • 2007
  • Valves has been used widely in various industries. There are many purposes for valve usage in a piping system. One of them is to control the flow rate. For a design of ball valves, it is important to know the characteristics of flows inside a ball valve. In this study, the computation fluid dynamics were conducted to observe flow velocity, flow coefficient and pressure distribution using CFX 10 according to the valve angles and uniform incoming velocity.

  • PDF

Structural-Acoustic Coupled Analysis of Buried Hydrophone System (매설형 하이드로폰 시스템의 구조-음향 연성 해석)

  • Seo, Hee-Seon;Cho, Yo-Han;Joh, Chee-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1090-1095
    • /
    • 2007
  • A study was carried out to investigate the fluid-structure interaction phenomena of buried hydrophone system that exposed complex loads due to handling, transportation and installation. The buried hydrophone system has necessarily neighborhood structures for installation. Because of the neighborhood structure, acoustic field is deformed. We analyze the piezoelectric-structural-acoustic coupled problem and the results to use a finite element analysis software, ANSYS, which has an coupled field analysis capability. The effect of the component of hydrophone system is revealed altogether in pressure distribution. So, we classify and analyze the problem by four different compositions for decomposition.

  • PDF

An Isothermal Temperature Source with a Large Surface Area using the Metal-Etched Microwick-Inserted Vapor Chamber Heat Spreader

  • Go, Jeong-Sang;Kim, Kyung-Chun
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.681-688
    • /
    • 2004
  • For use of the thermal cycle of the biochemical fluid sample, the isothermal temperature source with a large surface area was designed, fabricated and its thermal characterization was experimentally evaluated. The comprehensive overview of the technology trend on the temperature control devices was detailed. The large surface area isothermal temperature source was realized by using the vapor chamber heat spreader. The cost-effectiveness and simple manufacturing process were achieved by using the metal-etched wick structure. The temperature distribution was quantitatively investigated by using IR temperature imaging system at equivalent temperatures to the PCR thermal cycle. The standard deviation was measured to be within 0.7$^{\circ}C$ for each temperature cycle. This concludes that the presented isothermal temperature source enables no temperature gradient inside bio-sample fluid. Furthermore it can be applied to the cooling of the electronic devices due to its slimness and low thermal spreading resistance.