• Title/Summary/Keyword: Fluid Distribution

Search Result 1,682, Processing Time 0.031 seconds

Optimization of Blade Profile of a Plenum Fan

  • Wu, Lin;Dou, Hua-Shu;Wei, Yikun;Chen, Yongning;Cao, Wenbin;Ying, Cunlie
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.1
    • /
    • pp.95-106
    • /
    • 2016
  • A method of optimization design for the blade profile of a centrifugal impeller by controlling velocity distribution is presented, and a plenum fan is successfully designed. This method is based on the inner flow calculation inside the centrifugal impeller, and is related to the distribution of relative velocity. The results show that after optimization, the boundary layer separation on the suction surface has been inhibited and the stability of plenum fan is improved. The flow at the impeller outlet is also studied, and the jet-wake pattern at the impeller outlet is improved obviously by optimization. The calculation result shows that the static pressure and static pressure efficiency can be increased by 15.4% and 21.4% respectively.

Development of Flow Control Valves for Hot Water Distribution Manifolds (온수분배기용 유량제어밸브의 개발)

  • Kwon, Woo-Chul;Yoon, Joon-Yong;Yoo, Sun-Hak
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.4
    • /
    • pp.11-17
    • /
    • 2010
  • The developed control valves, installed on the hot water distribution manifolds for the floor heating system, consist of the balancing valves and the shut-off valves. The balancing valve was designed to improve the flow control performance and to reduce the noise emitted from the valve by modification of the general V port. The port of the shut-off valve was designed with two ceramic plates, working by rotating upper plate, to improve the duration and to reduce the noise. For the evaluation of the new valves, the flow rate was measured and noise level test was carried out. The test results showed that the error of the flow rate accuracy test for the flow balance of each manifold circuit was less than ${\pm}3%$ and the noise level was less than 35 dB(A).

A Study on Estimation of inner and Wall Pressure Distribution by 3-Dimensional velocity Measurement using PIV (PIV를 이용한 3차원 속도계측에 의한 유동장의 공간 및 벽면압력 분포 추정에 관한연구)

  • 이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.4
    • /
    • pp.468-480
    • /
    • 1998
  • A flow measurement system which is able to measure the instantaneous three-dimensional velocity components and the pressure distribution of fluid flows is developed using a digital image processing system and the stereoscopic photogrammetry. This system consists of two TV cameras a digital image processor and a 32-bit microcomputer. The capability of the developed system is verified by a preliminary test in which three-dimensional displancements of moving particles arranged on a rotating plate are tracked automatically. The constructed system is through the measurement and spatial pressure distribution is also obtained. The measurement uncertainty of this system is evaluated quantitatively. The present technique is applicable to the measurement of an unsteady fluid phenomenon especially to the measurement of three-dimensional velocity field of a complex flow.

  • PDF

Computational Study on Design of the AIG for the Enhancement of Ammonia Injection in the SCR System (SCR 시스템 내 암모니아 분사 균일도 개선을 위한 AIG 설계에 관한 해석적 연구)

  • Seo, Moon-Hyeok;Chang, Hyuksang
    • Clean Technology
    • /
    • v.18 no.4
    • /
    • pp.410-418
    • /
    • 2012
  • The performance of the ammonia injection gun (AIG) used for maximizing the utilization of reducing agent in the selective catalytic reduction (SCR) system is decided by several parameters such as the pattern of flow distribution, geometry of the air distribution manifold (ADM) and the array and geometry of nozzles. In the study, the uniformity of jet flows from the nozzles in AIG was analyzed statistically by using the computational fluid dynamics (CFD) method to evaluate the role of design parameters on the performance of the SCR system. The uniformity of jet flows from the nozzles is being deteriorated with increasing the supplying flow rate to the AIG. Distribution rates to each branch pipe become lower with decreasing distance to the header, and flow rates from nozzle are also reduced with decreasing distance to the header. The uniformity of jet flows from nozzles becomes stable significantly when the ratio of summative area of nozzles to each sectional area of the branch pipe is below 0.5.

A Numerical Study of the Effects of Mass Flow Rate Distribution on the Flow Characteristics in a Two Dimensional Multi-Jet with Crossflow of the Spent Fluid (직교류를 가지는 이차원 다중젯트에서 유량분포가 유동특성에 미치는 영향)

  • 강동진;오원태
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.8
    • /
    • pp.1940-1949
    • /
    • 1995
  • A numerical study for a two dimensional multi-jet with crossflow of the spent fluid has been carried out. Three different distributions of mass-flow rate at 5 jet exits were assumed to see their effects upon the flow characteristics, especially in the jet-flow region. For each distribution, various Reynolds numbers ranging from laminar to turbulent flows were considered. Results show that a fully developed laminar flow exists above a certain Reynolds number whose exact value depends upon the mass flow rate distribution. AS the Reynolds number increases, the flow becomes transitional from downstream and finally a fully developed turbulent flow forms in the jet-flow region. The critical Reynolds number where the fully developed turbulent flow forms is quite dependent upon the distribution of mass-flow rate. One interesting result is that the distribution of the skin friction coefficient along the inpingement plate in the jet-flow region shows a consistent dependency on the Reynolds number, i.e. inversely proportional to the square root of the Reynolds number, regardless of flow regime.

Effects of decay heat and cooling condition on the reactor pool natural circulation under RVACS operation in a water 2-D slab model

  • Min Ho Lee ;Dong Wook Jerng ;In Cheol Bang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1821-1829
    • /
    • 2023
  • The temperature distribution of the reactor pool under natural circulation induced by the RVACS operation was experimentally studied. According to the Bo' based similarity law, which could reproduce the temperature distribution of the working fluid under natural circulation, SINCRO-2D facility was designed based on the PGSFR. It was reduced to 1 : 25 in length scale, having water as a simulant of the sodium, which is the original working fluid. In general, temperature was stratified, however, effect of the natural circulation flow could be observed by the entrainment of the stratified temperature. Relative cooling contribution of the upper plenum (narrow gap) and lower plenum was approximately 0.2 and 0.8, respectively. In the range of decay heat from 0.2% to 1.0%, only the magnitude of the temperature was changed, while the normalized temperature maintained. Boundary temperature distribution change made a global temperature offset of the pool, without a significant local change. Therefore, the decay heat and cooling boundary condition had no significant effect on temperature distribution characteristics of the pool within the given range of the decay heat and boundary temperature distribution.

A study on post-formula instruction of Kyejitang(桂枝湯) (계지탕(桂枝湯) 방후주문(方後註文)에 관한 연구(硏究))

  • Kim, Kang;Meang, Woongjae
    • The Journal of Korean Medical History
    • /
    • v.23 no.1
    • /
    • pp.23-41
    • /
    • 2010
  • Greater yang disease(太陽病) is a syndrome induced by peripheral obstruction. One of them is "wind stroke(中風)" with the obstruction in lymphatic system. The other obstruction appearing on circulatory system is called "cold damage(傷寒)." Kyejitang(桂枝湯) is the formula prescribed for greater yang wind stroke pattern(太陽中風證) which is caused by peripheral lymphatic duct obstruction. Ramulus Cinamoni acts as a vasodilator and Radix Paeoniae relieves the abdominal tension. They make blood move to the internal organ and this can remove the retention of peripheral lymphatic system. Covering the patient with a blanket and getting him/her to have hot and thin rice gruel causes slight Diaphoresis, contributing to relieving the retention of lymphatic system. Disharmony between nutrient and defense(營衛不和) means that pressure becomes different between lymphatic system and vascular system. Kyejitang(桂枝湯) is called releasing muscles formula(解肌劑) because it can resolve such pressure difference. Diaphoresis is not a means to eliminate pathogenic qi(邪氣) from the body. That is the syndrome proving that the body fluid has moved around when disordered fluid distribution is corrected. Therefore, diaphoresis should be induced weakly all the time. If diaphoresis is induced excessively, body fluid will move more than desired and then illness cannot be cured. In Sanghanlun(傷寒論), dispersing drugs aim at addressing the retention in the exterior field, but it actually applies to the entire exterior and interior to make body fluid move. Therefore, diaphoresis does not just act on exterior field, and freeing the stool does not only apply to interior field. Distribution of body fluid changed by pathogenic qi(邪氣) influences the whole body because the human body has a closed circulatory system. Sanghanlun(傷寒論) has included treatments for pathogenic disease. However, its value should not be limited to pathogenic disease. It is because controlling blood flow by sending body fluid to the place a doctor wants is certainly worth using for treatment of non-exogenous disease or chronic illnesses.

Development of CAE tool for reducing vibration of pipe-mount system conveying fluid (유동이 있는 배관-마운트 계의 진동저감설계 CAE Tool개발)

  • Lee, Seong-Hyeon;Jeon, Su-Hong;Jeong, Weui-Bong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.472-473
    • /
    • 2008
  • In this research, the finite element model is formulated taking into consideration of the effects of the fluid flow in a pipe. The characteristic of vibration is presented using mass, damping and stiffness matrix in the finite element equation of this pipe system. The displacement distribution of pipe system caused by fluid force is discussed. The method for optimizing the location of mount and the value of mount stiffness to reduce the vibration of pipe system is introduced.

  • PDF

Mount design to reduce the vibration of pipe system conveying fluid (유체를 운반하는 배관계의 진동 저감을 위한 마운트 설계)

  • Lee, Seong-Hyeon;Jeong, Weui-Bong;Jeong, Cheol-Ung;Ham, Il-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1437-1441
    • /
    • 2007
  • This paper formulates the finite element model is formulated taking into consideration of the effects of the fluid flow in a pipe. The characteristic of vibration is presented using mass, damping and stiffness matrix in the finite element equation of this pipe system. The displacement distribution of pipe system caused by fluid force is discussed. The variation of vibration of a pipe system according the change of mount stiffness is discussed.

  • PDF

Calculation of Temperature Rise in Gas Insulated Busbar by Coupled Magneto-Thermal-Fluid Analysis

  • Kim, Hong-Kyu;Oh, Yeon-Ho;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.4
    • /
    • pp.510-514
    • /
    • 2009
  • This paper presents the coupled analysis method to calculate the temperature rise in a gas insulated busbar (GIB). Harmonic eddy current analysis is carried out and the power losses are calculated in the conductor and enclosure tank. Two methods are presented to analyze the temperature distribution in the conductor and tank. One is to solve the thermal conduction problem with the equivalent natural convection coefficient and is applied to a single phase GIB. The other is to employ the computational fluid dynamics (CFD) tool which directly solves the thermal-fluid equations and is applied to a three-phase GIB. The accuracy of both methods is verified by the comparison of the measured and calculated temperature in a single phase and three-phase GIB.