• Title/Summary/Keyword: Fluid Atomization

Search Result 155, Processing Time 0.021 seconds

Evaluation of the cavitation effect on liquid fuel atomization by numerical simulation

  • Choi, Sang In;Feng, Jia Ping;Seo, Ho Suk;Jo, Young Min;Lee, Hyun Chang
    • Korean Journal of Chemical Engineering
    • /
    • v.35 no.11
    • /
    • pp.2164-2171
    • /
    • 2018
  • Heavy duty diesel vehicles deteriorate urban air quality by discharging a large volume of air pollutants such as soot and nitrogen oxides. In this study, a newly introduced auxiliary device a fuel activation device (FAD) to improve the combustion efficiency of internal engines by utilizing the cavitation effect was closely investigated by the fluid flow mechanism via a numerical analysis method. As a result, the FAD contributed to fuel atomization from the injection nozzle at lower inlet pressure by reducing the pressure energy. The improved cavitation effect facilitated fuel atomization, and ultimately reduced pollutant emission due to the decrease in fuel consumption. The axial velocity along the flow channel was increased 8.7 times with the aid of FAD, which improved the primary break-up of bubbles. The FAD cavitation effect produced 1.09-times larger turbulent bubbles under the same pressure and fuel injection amount than without FAD.

Spray characteristics on mixing region scale of twin fluid atomizer (이류체 분사노즐의 혼합영역 형상에 따른 분무특성)

  • 김병문;김혁주;이충원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.2147-2159
    • /
    • 1991
  • The effects of principal dimensions of internal mixing twin-fluid atomized and operating conditions on the atomizing characteristics are experimentally investigated. The tests are conducted over the wide range of air/liquid ratio to predict influences of the diameter and length of nozzle, contacting angle between air and liquid in the mixing chamber, and air orifice diameter on the mean drop size(SMD), spray angle, distribution of drop size, and spray dispersion, And also, initial distribution of liquid column by air stream within the mixing chamber are observed through the transparent nozzles. A He-Ne laser particle sizer(MALVERN Model 2604) was used to measure the Sauter.s mean diameter( $D_{321}$) and droplet sizes distribution. In this experiment the air/liquid ratio, mixing length and nozzle diameter have a great influence on SMD, spray angle, droplet sizes distribution and spray dispersion.

Atomization Characteristics of Effervescent Twin-fluid Nozzle with Different Nozzle Shapes (노즐 형상에 따른 Effervescent 이유체 노즐의 분무특성)

  • Lee, Sang Ji;Hong, Jung Goo
    • Journal of ILASS-Korea
    • /
    • v.22 no.3
    • /
    • pp.146-152
    • /
    • 2017
  • An experimental study was carried out to investigate the spray characteristics of non-circular effervescent twin-fluid nozzles. For this purpose, two types of non-circular nozzles (E1, E2) and circular nozzle (C) were used. Three types of aerorators with hole diameters of 1.2, 1.7 and 2.1 mm were used. Each aerorator has a total of 12 holes. It is defined by area ratio which is ratio of exit orifice area and aerator hole area. Experiments were carried out by controlling the amount of air flowing after fixing the flow rate of the liquid, and the nozzle internal pressure and SMD were measured, and the jet image was taken from the nozzles. The discharge coefficients of the three kinds of nozzles were compared with the used in plain orifice's equation and the Jedelsky's equation, and the Jedelsky's equation was found to be about 3 times larger. In addition, empirical formula based on ALR, which is the largest variable in Jedelsky's equation, was derived. The droplet sizes(SMD) were found to be smaller in the non-circular shape than in the circular shape, which is concluded to be caused by the difference of the discharge coefficients.

Improvement of the Efficiency of a Twin-fluid Nozzle using Ultrasonic Vibration (초음파 가진을 이용한 2-유체 노즐의 효율 향상)

  • 주은선;나우정;정진도;송민근;이경열
    • Journal of Biosystems Engineering
    • /
    • v.27 no.4
    • /
    • pp.317-326
    • /
    • 2002
  • Characteristics of a twin-fluid spray with ultrasonic vibration were examined in order to obtain a high efficiency of cold-fog spray of the automatic pest control machine which has been widely used in protected horticulture recently. An electrostrictive vibrator of PZT BLT and a magnetostrictive $\pi$-type vibrator were used applied as the ultrasonic transducers with a frequency of 28 kHz. All experiments were conducted in 4 methods of spray ; a conventional spray method without ultrasonic forcing, an indirect vibration method with ultrasonic forcing, an improving-quality method by ultrasonic forced within liquid, and a combined-use method with both of the indirect vibration method and the improving quality method. It was found that the ultrasonic energy increased the atomization efficiency of spray droplets about 10% and especially much more in the case of the combined-use method.

Spray characteristics of misaligned impinging injectors

  • Subedi, Bimal;Son, Min;Kim, Woojin;Choi, Jangsu;Koo, Jaye
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.10
    • /
    • pp.1257-1262
    • /
    • 2014
  • The variances of atomization characteristics with the misalignment of injectors defined as the fraction of skewness for various angles of impingement and pressure conditions were studied using the doublet impinging injectors with a like-on-like arrangement. Water was used as simulant and the spray characteristics along with the changes in the skewness were analyzed using the methods of spray image photography. Experiment was carried for the impinging nozzles of orifice diameter of 1.2 mm within Reynolds numbers ranging from $9{\times}10^3-4.5{\times}10^4$ and the fraction of skewness considered for the experiment ranges from 0.0 to 0.9 at ambient temperature condition. Flat sheet with a distinct rim produced perpendicular to the plane of impinging jets goes ondisappear and sheet appears comparatively shorterwith the increase in fraction of skewness resulting the atomization of fluid droplet very close to impingement point with decrease in breakup length and increase in spray angle up to certain extent. The maximum allowable skewness was found as the result. The skewness up to the certain extent can be considered as the parameter to control the atomization characteristics of simulant inside the combustion chamberproviding the high economic performance of fuel and time.

An Experimental Study on the Effect of Electrohydrodynamic Monodisperse Atomization According to Nozzle Characteristics (노즐 특성에 따른 전기수력학적 단분산 미립화 효과에 관한 실험적 연구)

  • Sung, K.A.;Lee, C.S.
    • Journal of ILASS-Korea
    • /
    • v.10 no.2
    • /
    • pp.18-31
    • /
    • 2005
  • This study was performed to explore the liquid breakup and atomization characteristics for the classification of drop formation mode and background of uniform droplets generation in electrohydrodynmaic atomization according to the change of experimental parameters such as nozzle material (stainless steel. teflon). fluid flow rate, applied electrical field and intensity, and frequency. In results, from the classification map of drop formation modes according to the variation of applied AC voltage and frequency at a stainless nozzle, the droplet size was smaller than the outer diameter of the nozzle tip relatively in the spindle mode. The transition points became clearly to be moved toward the high applied voltage by rising the applied AC frequency beyond 450Hz. Also the droplet radius can be observed quite small in the frequency bandwidth of $350{\sim}450Hz$. The droplet radiuses decrease as the applied voltage increases for a fixed applied AC frequency within the range from 50Hz to 400Hz Over 400Hz, the relation between the power intensity and the droplet size was not consistent with a continuous mechanism of liquid breakup. Thus, it is showed that the droplet size distribution using the teflon nozzle was analogous to the results of stainless steel, but the droplet size was bigger than that of stainless steel relatively in case of a teflon nozzle.

  • PDF

A Numerical Analysis of Internal Nozzle Flows Through the Multi-Fluid Model (다유체 모델을 이용한 노즐 내부 유동에 대한 수치적 연구)

  • Ryu, Bong-Woo;Lee, Chang-Sik
    • Journal of ILASS-Korea
    • /
    • v.16 no.4
    • /
    • pp.186-194
    • /
    • 2011
  • This study performed the numerical analysis of the internal nozzle flows including cavitation phenomena by using the automated body-fitted grid generator and the multi-fluid model. The effect of grid refinement and the validation of multifluid model were investigated using four computational meshes under two test conditions. The mesh #3 was chosen as the optimum which can reduce the computational time and have good prediction ability to identify the cavitation region simultaneously. In addition, the computed results using multi-fluid model were compared with the reference experimental observations and numerical simulation results using homogeneous equilibrium model. From the distribution of volume fraction and velocity field, the multi-fluid model predicted the internal nozzle flows well when the liquid quality parameters were selected as $1.0{\times}10^{12}$ for initial number density and 25 ${\mu}m$ for bubble diameter.

Analysis for Local Structure of Gaseous Hydrogen/liquid Oxygen Flame at Supercritical Pressures (초임계 압력상태에서 기체수소/액체산소 국소화염구조 해석)

  • Kim, Tae-Hoon;Kim, Seong-Ku;Kim, Yong-Mo
    • Journal of ILASS-Korea
    • /
    • v.15 no.4
    • /
    • pp.182-188
    • /
    • 2010
  • Significant real fluid behaviors including rapid property changes take place where high pressure combustion devices such as rocket engines. The flamelet model is the reliable approach to account for the real fluid effects. In the present study, the flamelet equations are extended to treat the general fluids over transcritical and supercritical states. The real fluid flamelet model is carried out for the gaseous hydrogen and cryogenic liquid oxygen flames at the wide range of thermodynamic conditions. Based on numerical results, the precise discussions are made for effects of real fluid, pressure, and differential diffusion on the local flame structure.

Study on the Structures of the Nozzle for the Spray (분무기용(噴霧機用) Nozzle의 구조(構造)에 관한 연구(硏究))

  • Lee, S.W.
    • Journal of Biosystems Engineering
    • /
    • v.18 no.2
    • /
    • pp.100-109
    • /
    • 1993
  • The aim of this study was to provide the reasonable data for design of the nozzle which produces finer droplets on the same level of the effective travel distance or which transports droplets to the farther target on the reasonable atomization in comparison with the commercial nozzles being used much in Korean rural areas. Newly designed twin-fluid atomizers with some commercial nozzles were tested in this study, and their results were as follows : 1. The characteristics of the spray deposit distribution of No.1 nozzles for farther target were nearly same in the near or nearer travel distance less than 8m. Therefore it was reasonable to combine the characteristics of the spray deposit distributions of No.2 and No.3 nozzles to those of No.1 nozzle. 2. The effective travel distance was increased with increase of the sectional area of the jet ligament, and the maximum effective travel distance was reached to about 17m. 3. The droplet size was increased with increase of the sectional area of the jet ligament, and the maximum droplet size was produced in the front of the point of the maximum spray deposit distribution. 4. The atomization was excellent in the twin-fluid atomizer in comparison with the hydraulic atomizer and also the effective travel distances were nearly same level in both atomizers.

  • PDF

A Study on the Spray Characteristics of the Cold-Fog Spray with Ultrasonic Forcing (초음파적용 상온연무기의 분무특성에 관한 연구)

  • Song Min-Geun;Lee Kyung-Youl;Son Sung-Woo;La Woo-Jung;Ju Eun-Sun
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.299-302
    • /
    • 2002
  • Characteristics of the twin fluid spray with ultrasonic forcing are examined in order to obtain the high efficiency of cold fog spray of the automatic pest control machine which has been widely used for the equipment cultivation recently. An electrostrictive vibrator of PZT BLT and a magnetostrictive vibrator of ${\pi}type$ with 28 kHz are applied as the ultrasonic transducer. All experiments are made and observed in 4 methods of spray ; a conventional spray method without ultrasonic forcing, an indirect vibration method with ultrasonic forcing, an improving duality method by ultrasonic forced within liquid, and a combined use method with both of the indirect vibration method and the improving quality method. In results, It was clarified that the ultrasonic effects the atomization of spray droplets and its efficiency is about $10{\%}$ and especially much more in the case of the combined use method.

  • PDF