A Study on the Fluid Mixing Analysis for Proving Shell Wall Thinning of a Feedwater Heater (급수가열기 동체 감육 현상 규명을 위한 유동해석 연구)

  • Shin, Min-Ho;Hwang, Kyeong-Mo;Kim, Kyung-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2017-2022
    • /
    • 2004
  • There are multistage preheaters in the power generation plan to improve the thermal efficiency of the plant and to prevent the components from the thermal shock. The energy source of these heaters comes from the extracted two phase fluid of working system. These two-phase fluid can cause the so-called Flow Accelerated Corrosion(FAC) in the extracting piping and the bubble plate of the heater for example, in case of point Beach Nuclear Power Plant and in the Wolsung Nuclear Power Plant. The FAC is due to the mass transport of the thin oxide layer by the convection. FAC is dependent on many parameters such as the operation temperature, void fraction, the fluid velocity and pH of fluid and so on. Therefore, in this paper velocity was calculated by FLUENT code in order to find out the root cause of the wall thinning of the feedwater heaters. It also includeed in the fluid mixing analysis model are around the number 5A feedwater heater shell including the extraction pipeline. To identify the relation between the local velocities and wall thinning, the local velocities according to the analysis results were compared with distribution of the shell wall thicknes by ultrasonic test.

  • PDF

Energy Flow Finite Element Analysis for High Frequency Acoustic and Vibrational Prediction of Complicated Plate Structures Considering Fluid-Structure Interaction (복합평판구조물의 고주파수 대역 유체/구조 연성 소음진동예측을 위한 에너지흐름유한요소해석)

  • Tae-Heum Yoon;Young-Ho Park
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.1
    • /
    • pp.20-30
    • /
    • 2023
  • In this paper, the Energy Flow Finite Element Analysis (EFFEA) was performed to predict the acoustic and vibrational responses of complicated plate structures considering improved Fluid-Structure Interaction (FSI). For this, a new power transfer relationship was derived at the area junction where two different fluids are in contact on both sides of the plate. In order to increase the reliability of EFFEA of complicated plate structures immersed in a high-density fluid, the corrected flexural wavenumber and group velocity considering fluid-loading effect were derived. As the specific acoustic impedance of the fluid in contact with the plate increases, the flexural wavenumber of the plate increases. As a result, the flexural group velocity is reduced, and the spatial damping effect of the flexural energy density is increased. Additionally, for the EFFEA of arbitary-shaped built-up structures, the energy flow finite element formulation for the acoustic tetrahedral element was newly performed. Finally, for validation of the derived theory and developed software, numerical applications of complicated plate structures submerged in seawater or air were successfully performed.

The Equipment Design by the Fluid and Thermal Analysis of the Electromagnetic Pump for Recycling of Aluminum Scrap (알루미늄 스크랩의 재활용을 위한 전자기장 펌프의 열 유동 해석에 의한 장비 설계)

  • Choi, Woo-Sik;Kang, Chung-Gil
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.12 s.189
    • /
    • pp.64-71
    • /
    • 2006
  • In this study, to design aluminum scrap recycling equipment, fluid flow and thermal analysis considering electromagnetic phenomenon were carried out by using ANSYS program. The magnetic flux generated by electromagnetic pump has influence on fluid velocity of Al liquid metal with molten metal motion and thermal generation. To investigate the effect of the number of phase on fluid flow and thermal generation, electromagnetic force and magnetic flux were obtained by computer simulation. In addition, the results obtained by fluid flow and thermal analysis, recycling equipment of aluminum scrap with the cooling technology of electromagnetic coil, the most suitable phase and current were proposed.

Dynamic Analysis of a Rotating Blade Considering the Fluid Induced Exteral Force (유체유동에 의한 외력을 고려한 회전 블레이드의 동역학적 거동해석)

  • Seo, Seok;Yu, Hong-Hui;Yun, Jun-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.9 s.180
    • /
    • pp.2259-2265
    • /
    • 2000
  • A dynamic modeling of a rotating pretwist blade which interacts with the fluid is proposed in this study. The hybrid deformation variable modeling method is employed to derive the equations of motion. The external force and moment induced by the fluid (with fixed configurations of the blade) are obtained by fluid flow analysis and tabulated in a database. This database is efficiently utilized to save the computational effort to calculate the dynamic response of the blade. The numerical results show that the fluid affects the transient response as well as frequency characteristics of the system.

Experimental Modal Analysis of Perforated Rectangular Plates Coupled with Fluid (유체로 연성된 다공 직사각평판의 실험적 모드 해석)

  • 유계형;이명규;정경훈;이성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.900-903
    • /
    • 2002
  • This study dealt with the experimental modal analysis of the perforated rectangular plate coupled with fluid. The natural frequencies of the perforated plate and solid plate in air were obtained by the analytical method based on the relation between the reference kinetic and maximum potential energy and compared with the experimental results. Good agreement between the results was found for the natural frequencies of the perforated plate in air. It was empirically found the natural frequencies of the perforated plate coupled with fluid. The transverse vibration modes, in-phase and out-of-phase, were observed alternately in the fluid-coupled system. Additionally, the effect of distance between perforated plate and solid plate on the fluid-coupled natural frequency was investigated.

  • PDF

ADINA/FSI Analysis of Petrochemical Plant Column Mixer (화학 플랜트용 칼럼 믹서의 ADINA/FSI 해석)

  • Lee, Won-Suk;Jung, Goo-Choong;Choi, Yeon-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.916-921
    • /
    • 2006
  • Column mixer is one of the facility to mix fluids at petrochemical plants. The column vibration is caused by pumps for fluid inflow and mixing of inside fluids. This fluid induced vibration is mainly responsible for the reduction of column life. Measurements were performed three times for understanding the vibration characteristics of the column. First experimental results showed the need of stiffness reinforcement. After the reinforcement work, second measurement conformed the difference between two results. Modal analysis was also performed to investigate the resonance of the column vibration and the damage of the rib plate. To confirm the generation of the fluid instability in the column mixer fluid structure interaction analysis using ADINA/FSI was performed which showed the necessity of the modification of the rotary valve.

  • PDF

Development of Simultaneous Quantification Method of Phenylalkylamines in Oral Fluid (타액 중 페닐알킬아민유도체류의 일제분석법 확립)

  • Choi, Hye-Young;Baeck, Seung-Kyung;Jang, Moon-Hee;Choi, Hwa-Kyung;Chung, Hee-Sun
    • YAKHAK HOEJI
    • /
    • v.55 no.2
    • /
    • pp.145-153
    • /
    • 2011
  • A simultaneous detection and quantification method for determining the Phenylalkylamine derivatives, such as methamphetamine (MA), amphetamine (AM), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), ketamine (KT), norketamine (NKT), phentermine (PT), fenfluramine (FFA) and phenmetrazine (PM), in oral fluid was developed and validated according to international guidelines. The validated method was applied to actual oral fluid samples collected from drug abuse suspects. The recovery of phenylalkylamines from oral fluid collection devices was also assessed. Oral fluid specimens from 20 drug abuse suspects submitted by the police were collected using Salivette$^{TM}$, Quantisal$^{TM}$ or direct expectoration. The samples were screened using a biochip array analyzer. For confirmation, the samples were analyzed by GC-MS in selected-ion monitoring (SIM) mode after extraction using automated SPE with a mixed-mode cation exchange cartridge and derivatization with trifluoroacetic anhydride (TFAA). The results from the immunoassay were consistent with those from GC-MS. All the oral fluid samples gave positive results for MA, AM, PT and/or PM. The detection of phenylalkylamines in oral fluid can provide a better indication of recent use than urine or hair. Therefore, the oral fluid specimen was useful for demonstrating phenylalkylamines abuse in the driving under the influence of drug (DUID) as an alternative specimen for urine.

Comparison of finite element analysis with wind tunnel test on stability of a container crane (컨테이너 크레인의 안정성에 대한 풍동실험과 유한요소해석의 비교)

  • Han, D.S.;Lee, S.W.;Han, G.J.
    • Journal of Power System Engineering
    • /
    • v.12 no.6
    • /
    • pp.29-35
    • /
    • 2008
  • This study is conducted to provide the proper analysis method to evaluate the stability of a container crane under wind load. Two analysis method, namely structure analysis and fluid-structure interaction, are adopted to evaluate the stability of a container crane in this investigation. To evaluate the effect of wind load on the stability of the crane, 50-ton class container crane widely used in container terminals is adopted for analysis model and 19-values are considered for wind direction as design parameter. We conduct structure analysis and fluid-structure interaction for a container crane with respect to the wind direction using ANSYS and CFX. Then we compare the uplift forces yielded from two analysis with it yielded from wind tunnel test. The results are as follows: 1) A correlation coefficient between structure analysis and wind tunnel test is lower than 0.65(as $0.29{\sim}0.57$), but between fluid-structure interaction and wind tunnel test is higher than 0.65(as $0.78{\sim}0.86$). 2) There is low correlation between structure analysis and wind tunnel test but very high correlation between fluid-structure interaction and wind tunnel test.

  • PDF