• 제목/요약/키워드: Fluent code

검색결과 389건 처리시간 0.021초

Slamming Load Analysis

  • LEE BEE-SUNG;KWON SUN-HONG;LEE JONG-HYUN;JUNG BYUNG-HOON;SONG KI-JONG
    • 한국해양공학회지
    • /
    • 제19권4호
    • /
    • pp.15-20
    • /
    • 2005
  • This paper presented the development of a new experimental and numerical technique for the investigation of slamming impact. The in-house code was developed, based on the boundary element method. The application of commercial code was attempted using FLUENT. Pneumatic cylinder and LM-guide were introduced to closely simulate the free fall phenomenon. It was demonstrated that the proposed experimental and numerical studies can be useful tools in investigating slamming phenomenon.

TWO-DIMENSIONAL SIMULATION OF HYDROGEN IODIDE DECOMPOSITION REACTION USING FLUENT CODE FOR HYDROGEN PRODUCTION USING NUCLEAR TECHNOLOGY

  • CHOI, JUNG-SIK;SHIN, YOUNG-JOON;LEE, KI-YOUNG;CHOI, JAE-HYUK
    • Nuclear Engineering and Technology
    • /
    • 제47권4호
    • /
    • pp.424-433
    • /
    • 2015
  • The operating characteristics of hydrogen iodide (HI) decomposition for hydrogen production were investigated using the commercial computational fluid dynamics code, and various factors, such as hydrogen production, heat of reaction, and temperature distribution, were studied to compare device performance with that expected for device development. Hydrogen production increased with an increase of the surface-to-volume (STV) ratio. With an increase of hydrogen production, the reaction heat increased. The internal pressure and velocity of the HI decomposer were estimated through pressure drop and reducing velocity from the preheating zone. The mass of $H_2O$ was independent of the STV ratio, whereas that of HI decreased with increasing STV ratio.

Comparative study of CFD and 3D thermal-hydraulic system codes in predicting natural convection and thermal stratification phenomena in an experimental facility

  • Audrius Grazevicius;Anis Bousbia-Salah
    • Nuclear Engineering and Technology
    • /
    • 제55권4호
    • /
    • pp.1555-1562
    • /
    • 2023
  • Natural circulation phenomena have been nowadays largely revisited aiming to investigate the performances of passive safety systems in carrying-out heat removal under accidental conditions. For this purpose, assessment studies using CFD (Computational Fluid Dynamics) and also 3D thermal-hydraulic system codes are considered at different levels of the design and safety demonstration issues. However, these tools have not being extensively validated for specific natural circulation flow regimes involving flow mixing, temperature stratification, flow recirculation and instabilities. In the present study, an experimental test case based on a small-scale pool test rig experiment performed by Korea Atomic Energy Research Institute, is considered for code-to-code and code-to-experimental data comparison. The test simulation is carried out using the FLUENT and the 3D thermal-hydraulic system CATHARE-2 codes. The objective is to evaluate and compare their prediction capabilities with respect to the test conditions of the experiment. It was observed that, notwithstanding their numerical and modelling differences, similar agreement results are obtained. Nevertheless, additional investigations efforts are still needed for a better representation of the considered phenomena.

CFD/RELAP5 coupling analysis of the ISP No. 43 boron dilution experiment

  • Ye, Linrong;Yu, Hao;Wang, Mingjun;Wang, Qianglong;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.97-109
    • /
    • 2022
  • Multi-dimensional coupling analysis is a research hot spot in nuclear reactor thermal hydraulic study and both the full-scale system transient response and local key three-dimensional thermal hydraulic phenomenon could be obtained simultaneously, which can achieve the balance between efficiency and accuracy in the numerical simulation of nuclear reactor. A one-dimensional to three-dimensional (1D-3D) coupling platform for the nuclear reactor multi-dimensional analysis is developed by XJTU-NuTheL (Nuclear Thermal-hydraulic Laboratory at Xi'an Jiaotong University) based on the CFD code Fluent and system code RELAP5 through the Dynamic Link Library (DLL) technology and Fluent user-defined functions (UDF). In this paper, the International Standard Problem (ISP) No. 43 is selected as the benchmark and the rapid boron dilution transient in the nuclear reactor is studied with the coupling code. The code validation is conducted first and the numerical simulation results show good agreement with the experimental data. The three-dimensional flow and temperature fields in the downcomer are analyzed in detail during the transient scenarios. The strong reverse flow is observed beneath the inlet cold leg, causing the de-borated water slug to mainly diffuse in the circumferential direction. The deviations between the experimental data and the transients predicted by the coupling code are also discussed.

열유속이 있는 난류 원관 유동에의 FLUENT의 2방정식 난류모델의 적용성 판단 (Assessment of two-equation turbulent models in FLUENT for a turbulent heated pipe flow)

  • 문치명;백성구;박승오
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 추계 학술대회논문집
    • /
    • pp.158-163
    • /
    • 2003
  • This paper assesses the two-equation turbulence models available in a commercial code, FLUENT, for heat transfer in a turbulent heated pipe flow. In case of flow under $Re_D=10,000$, Standard $\kappa-\epsilon$ and Realizable $\kappa-\epsilon$ models overpredict the Nusselt number about $20\%$ compared with the experimental correlation, and RNG $\kappa-\epsilon$ model overpredicts about $30\%$ when the two-layer zonal method is employed. When wall function method is adopted, all $\kappa-\epsilon$ models show better predictions. Standard $\kappa-\omega$ and SST $\kappa-\omega$ models have the dependency on the first grid point ($0.3). As Reynolds number becomes high, the predictions of all $\kappa-\epsilon$ and $\kappa-\omega$ models are in a good agreement with the experimental correlation.

  • PDF

FLUENT를 활용한 콘크리트 건식 저장용기 공기유로 내부 유동장 해석 (ANALYSIS ON FLOW FIELDS IN AIRFLOW PATH OF CONCRETE DRY STORAGE CASK USING FLUENT CODE)

  • 강경욱;김형진;조천형
    • 한국전산유체공학회지
    • /
    • 제21권2호
    • /
    • pp.47-53
    • /
    • 2016
  • This study investigated natural convection flow behavior in airflow path designed in concrete dry storage cask to remove the decay heat from spent nuclear fuels. Using FLUENT 16.1 code, thermal analysis for natural convection was carried out for three dimensional, 1/4 symmetry model under the normal condition that inlet ducts are 100% open. The maximum temperatures on other components except the fuel regions were satisfied with allowable values suggested in nuclear regulation-1536. From velocity and temperature distributions along the flow direction, the flow behavior in horizontal duct of air inlet and outlet duct, annular flow-path and bent pipe was delineated in detail. Theses results will be used as the theoretical background for the composing of airflow path for the designing of passive heat removal system by understanding the flow phenomena in airflow path.

산화제 벤트/릴리프밸브의 동특성 해석 및 작동성능분석 (Analysis of Dynamic Characteristics and Performances of Vent-Relief Valve)

  • 장제선;고현석;한상엽;이경원
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.741-747
    • /
    • 2010
  • 발사체의 추진공급시스템에 사용되는 벤트/릴리프밸브는 안전밸브의 조합체로 극저온의 산화제를 주입할 때와 비행 중에 기화된 산소기체를 배출시킨다. 벤트/릴리프밸브의 설계검증을 위해 AMESim과 FLUENT 상용코드를 이용하여 밸브모델을 구성하였다. AMESim 밸브모델을 검증하기 위해 밸브의 개폐압력, 개폐작동시간을 수학적 계산결과와 비교하였고 내부유동해석 결과를 반영하여 모델의 정확도를 높였다. 본 연구에서는 설계인자를 검증 및 작동성능을 분석하였다. 이 결과는 한국형 발사체에 사용되는 다양한 규격의 벤트/릴리프밸브 개발과정의 효율성을 높일 수 있을 것으로 판단된다.

  • PDF

이단 원추형 오리피스를 지니는 유동장에 대한 수치해석 (Numerical Analysis for the Flow Field past a Two-Staged Conical Orifice)

  • 김연수;김유곤
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.499-505
    • /
    • 2001
  • The objective of the paper was to measure the pressure drop and to investigate the recirculation region of the conical orifices used in Kwang-yang Iron & Steel Company. The flow field with water used as a working fluid was the turbulent flow for Reynolds number of $2{\times}10^4$. The effective parameters for the pressure drop and the recirculation region were the conical orifice's inclined angle (${\theta}$) against the wall, the interval(L) between orifices, the relative angle of rotation(${\alpha}$) of the orifices, the shape of the orifice's hole(circle, rectangle, triangle) having the same area. It was found that the shape of the orifice's hole affected the pressure drop and the flow field a lot, But the other parameters did not make much differences to the pressure drop. The PISO algorithm with FLUENT code was employed.

  • PDF

공력소음 모델을 이용한 슈라우드 팬 주위의 유동특성 및 소음예측에 관한 연구 (A Study on the Flow Characteristics and Noise Predictions around the Shroud Fan using the Aero-acoustic Noise Model)

  • 모장오;이영호
    • 한국유체기계학회 논문집
    • /
    • 제12권3호
    • /
    • pp.19-25
    • /
    • 2009
  • InThe purpose of this work is to analyze the flow characteristics and aerodynamic noise generated from a shroud fan at a constant 2,100 rpm using LES and FW-H noise model provided in the commercial code, FLUENT. Velocity distributions around the shroud fan obtained by using FLUENT code show good agreement with experimental results. The sound pressure level is decreased by about 6 dB as the distance from the fan increases twice. The directivity at 1st BPF shows a tendency of increasing SPL toward the axis of rotation.

자기축열식 저 NOx 연소기에서 배가스 재순환이 연소특성에 미치는 영향 (The Effect of Flue-gas Recirculation on Combustion Characteristics of Self Regenerative Low NOx Burner)

  • 강민욱;김종규;동상근;윤영빈
    • 한국연소학회지
    • /
    • 제8권1호
    • /
    • pp.17-24
    • /
    • 2003
  • The conventional regenerative system has a high thermal efficiency as well as energy saving using the high preheated combustion air. in spite of these advantages, it can not avoid high nitric oxide emissions. Recently, flameless combustion has received much attention to solve these problems. In this research, numerical analysis is performed for flow-combustion phenomena in the self regenerative burner. In this analysis we used Fluent 6.0 code. the that is developed for commercial use, Methane gas is used as a fuel and two-step reaction model for methane and Zeldovich mechanism for NO generation are used. the velocity of the preheated combustion air is used as a parameter and we analyze the characteristics of flow-field, temperature distributions and NO emissions. Due to the increased recirculation rate, the maximum temperature of flame is significantly increased and NOx emissions is reduced.

  • PDF