• 제목/요약/키워드: Fluent code

검색결과 389건 처리시간 0.024초

Plate and Shell 열교환기의 압력강하 특성에 관한 연구 (A study on the pressure drop characteristics of plate and shell heat exchangers)

  • 서무교;김영수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.25-30
    • /
    • 2000
  • Plate and shell heat exchanger(P&SHE) has been applied to the refrigeration and air conditioning systems as evaporators or condensers fur their high efficiency and compactness. The purpose of this study is to analyze the characteristics of pressure drop in plate and shell heat exchanger. An experiment for single phase (low pressure drop in plate and shell heat exchanger was performed. Also numerical work was conducted using the FLUENT code for $ {\kappa}-{\varepsilon}$ model. The dependence of friction factor on geometrical Parameters was numerically investigated. The study examines the internal flow and the pressure distribution in the channel of plate and shell heat exchanger. The results of CFD analysis compared with experimental data, and the difference of frictor factor in plate side and shell side are 10% and 12%, respectively. Therefore, the CFD analysis model is effectively predict the performance of plate and shell heat exchanger.

  • PDF

발전용 희박예혼합 가스터빈 연소기 내부유동 특성 해석 (A Numerical Analysis of the Flow Characteristics in a Lean Premixed Gas Turbine Combustor for Power Generation)

  • 정재화;서석빈;안달홍;김종진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.847-852
    • /
    • 2000
  • Three dimensional CFD investigations are carried out to understand the complex flow field in a gas turbine combustor with multi-element fuel injectors. The gas turbine considered here is the GE7FA model which has aye fuel injectors in each combustor can and utilizes lean-premixed combustion to meet nitric oxide emission requirements. Detailed three-dimensional flow characteristics and fuel-air mixture formation process inside the fuel nozzle and gas turbine combustor including five swirl nozzle tips are analyzed using commercial FLUENT code.

  • PDF

박용 발전기 냉각 팬 설계변경에 따른 유동해석 (Flow Analysis for Design Modification of Marine Generator Fan)

  • 김홍원;설신수;하지수;김진오
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.840-844
    • /
    • 2003
  • A study for increase of fan flow rate by geometric modification has been conducted to decrease temperature rise of marine generator inner part. Through experiment of a real product, a performance curve for various flow resistances was obtained. Flow analyses for each cases were done by using commercial code-FLUENT and the results were very similar to experimental data (0.7% deviation at normal operating condition). Through flow analysis results for various design geometric modification, a scroll type fan was adopted as a best design geometry with 100Pa more pressure and 22% more flow rate than original fan.

  • PDF

회전성형 제품의 성능 개선 (Improvement of Rotational Molding Products)

  • 이형민;김현주;이정기
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1834-1839
    • /
    • 2003
  • Temperature and velocity distributions of hot air flows in rotational molding machines with two different shapes and structures of oven and inlet were investigated by using FLUENT, a commercial computational fluid dynamics code. The shape and structure of oven and inlet in current rotational molding machine were improved. Two different sizes of mold inside each oven were considered in the analysis. Temperature and velocity distributions of hot air flows in two different rotational molding machines were compared to each other. In order to reduce cycle time and improve product quality in current rotational molding machine, the improved shape and structure of oven and inlet were proposed.

  • PDF

공기구동형 글로브 밸브의 3차원 유동 해석 (3D Flow Analysis of Globe Valve with Air Operated Actuator)

  • 정민호;양상민;이호영
    • 한국유체기계학회 논문집
    • /
    • 제8권4호
    • /
    • pp.7-13
    • /
    • 2005
  • Although the globe is the most typical valve to control high pressure drop in piping system, it is very hard to figure out the characteristics of flow field in the globe valve caused by its complex geometry, So there is very few studies to find out flow characteristics of globe valve. In this study numerical analysis for flow field in the globe valve is carried out using the FLUENT code which is commercial CFD program. Pressure drop through the globe valve is also measured to verify the results come from numerical analysis. Comparing experiment with numerical analysis, two results are very close to each other.

가스분무장치에서 열유동 특성에 관한 전산해석 (Numerical Simulation on Flow and Heat Transfer in a Gas Atomizer)

  • 이성연
    • 한국분말재료학회지
    • /
    • 제4권1호
    • /
    • pp.55-62
    • /
    • 1997
  • Flow and heat transfer characteristics of gas, and trajectories and cooling characteristics of droplets/particles in a gas atomizer were investigated by a numerical simulation using FLUENT code. Among several kinds of solution method, the k-$\varepsilon$ turbulent model, power-law scheme, SIMPLE algorithm is adopted in this study. Momentum and heat exchange between a continuous phase(gas) and a dispersed phase(particle) were taken into account. Particle trajectories are simulated using the Lagrangian method, and Rosin-Rammler formula is used for the particle size distribution. Streamlines, velocities and pressures of gas, and trajectories, velocities and cooling rates of particles have been investigated for the various gas inlet conditions. Small but very intensive recirculation is found just below the melt orifice, and this recirculation seems to cause the liquid metal to spread radially. Particle trajectory depends on the particle size, the location of particle formation and the turbulent motion of gas. Small particle cools down rapidly, while large diameter particles solidify slowly, and this is mainly due to the differences in thermal inertia.

  • PDF

중수로 기기냉각수 열교환기 내부 유동 해석 (Analysis of Internal Flow for Component Cooling Water Heat Exchanger in CANDU Nuclear Power Plants)

  • 송석윤
    • 한국압력기기공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.33-41
    • /
    • 2012
  • The component cooling water heat exchangers are critical components in a nuclear power plant. As the operation years of the heat exchanger go by, the maintenance costs required for continuous operation also increase. Most heat exchangers have carbon steel shells, tube support plates and flow baffles. The titanium tube is susceptible to flow induced vibration. The damage on carbon steel tube support rod and titanium tube around cooling water entrance area is inevitable. Therefore, analysis of internal flow around the component cooling water entrance and tube channel is a good opportunity to seek for failure prevention practice and maintenance method. The numerical study was carried out by FLUENT code to find out the causes of tube failure and its location.

NOx저감을 위한 연료희박 재연소 기법의 실험 및 수치적 연구 (Experimental and Numerical Investigation for NOx Reduction with Fuel Lean Reburning System)

  • 김학영;백승욱;손희;김세원
    • 한국연소학회지
    • /
    • 제14권2호
    • /
    • pp.18-25
    • /
    • 2009
  • Fuel lean reburning method is very attractive way in comparison with conventional reburning method for reducing NOX. Meanwhile, the knowledge of the how flue gas re-circulated, temperature distribution and species concentration is crucial for the design and operation of an effective fuel lean reburning system. For this reason, numerical analysis of fuel lean reburning system is a very important and challenge task. In this work, the effect of fuel lean reburn system on NOX reduction has been experimentally and numerically conducted. Experimental study has been conducted with a 15kW lab scale furnace. Liquefied Petroleum Gas is used as main fuel and reburn fuel. To carry out numerical study, the finite-volume based commercial computational fluid dynamics (CFD) code FLUENT6.3 was used to simulate the reacting flow in a given laboratory furnace. Steady state, three dimensional analysis performed for turbulent reactive flow and radiative heat transfer in the furnace.

  • PDF

Orifice Type의 유압실린더 유동해석에 관한 연구 (Study on the hydraulic cylinder flow analysis of Orifice Type)

  • 배강열;전진성
    • 동력기계공학회지
    • /
    • 제19권6호
    • /
    • pp.54-59
    • /
    • 2015
  • This paper is a numerical study on the correlation of leakage by the variation of operating temperature and orifice diameter applying to hydrostatic bearing in hydraulic actuator. Compared with Brackbill and Kandlikar experimental paper to verify the validity of the numerical analysis technique of the present study, we derive the result that the results of experiments and numerical analysis to match very well. CFD analysis program were analyzed using a commercial code FLUENT V14.5. Inlet and outlet, were applied pressure conditions, the main variables of the analysis is temperature and the orifice inner diameter. The analysis results, pressure value has decreased as the oil temperature and the orifice diameter increases.

사판식 유압 피스톤 펌프용 Slipper Bearing내의 유동해석 (Flow Analysis in a Slipper Bearing for Swash Plate Type Axial Piston Pump)

  • 박태조;유재찬
    • Tribology and Lubricants
    • /
    • 제24권6호
    • /
    • pp.343-348
    • /
    • 2008
  • In this paper, a CFD (Computational fluid dynamics) code, FLUENT is adopted to investigate accurate flow characteristics for a slipper bearing which is used swash plate type hydraulic axial piston pump. Static pressure and velocity distributions, and velocity vectors are plotted for different film thickness and slipper rotational velocity. In recess region, there exists a doughnut shaped vortex ring. The static pressure distributions are non-uniform and the flow fields are highly asymmetrical under bearing rotation. Therefore the numerical method adopted in this paper can be use in design of hydrostatic components and further studies are required.