• Title/Summary/Keyword: Flue Channel

Search Result 3, Processing Time 0.018 seconds

Performance Analysis on the Ejector System in Flue-gas Discharge Channel of Marine Incinerator (소각기의 배기가스 유로에 이젝터를 적용한 시스템의 성능 분석)

  • Yun, Sang-Kook;Chang, Ho-Gil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.773-778
    • /
    • 2011
  • The International Maritime Organization(IMO) could try to adopt more severe amendment to prevent any air pollution from various waste materials by marine incinerator. This study is to analyse the performance improvement through Ansys CFD about new invented system which has three flue-gas discharge channels and sub-ejector installed in the dischage channel in order to evacuate flue-gas well from the combustion chamber. The results showed that the discharge temperature of flue-gas was below the regulated value of IMO by the multi-channels, and the sub-ejector system installed in the discharge channel was highly effective one to improve the flue-gas discharge ability.

Numerical Analysis of Heat Flow and Heat Transfer in Flue Channel of Two-Dimensional Ondol Panel Heating System (2차원(次元) 온돌 상난방(床煖房)시스템의 연도내 열유동(熱流動) 및 열전달(熱傳達) 수치해석(數値解析))

  • Kim, Y.D.;Min, M.K.;Lee, S.H.;Kim, W.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.337-343
    • /
    • 1994
  • Numerical analysis was applied to a simplified two-dimensional Ondol heating model which consists of heating space on the top of it along with radiant and convective heating floor panel, flue channel in the midway and rectangular underground soil region at the bottom. These three components constitute a system thermally coupled at the top and bottom interfaces of the flue channel. Investigated in the present paper are effects with variations of the Reynolds numbers of 100, 200, and 300, Grashof numbers of $0.1{\times}10^6$ and $0.3{\times}10^6$ and aspect ratios of 15 and 20 on the heat transfer and fluid flow characteristics of two-dimensional Ondol heating model by computer simulation.

  • PDF

Numerical Analysis on the Flow Distribution in Ondol Flue Channel (산고래 온돌연도내의 유동분포에 관한 수치해석)

  • Man Man-Ki;Lee Seung Woo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.12 no.4
    • /
    • pp.264-274
    • /
    • 1983
  • Two-dimensional jet flows into a couple of confined rectangular enclosures such as an Ondol flue channel and their flow distributions were analyzed by numerical graphics : rectangular space in one enclosure is vacated and the other has 8 rectangular small posts. Both enclosures have a protruded inlet nozzle and on outlet on its center line. Steady state incompressible laminar viscous flow was assumed. The primitive forms of Navier-Stokes equations and continuity equation in a cartesian coordinate system were solved numerically by the Marker and Cell method for Reynolds numbers of 5, 10, 20, 30 and 40. From the numerical graphics it was found that the flow regions in both enclosures were devided into tow parts ; one part was the jet flow localized in a narrow center region of the enclosure and the other part was the very slow recirculating flow occupying the rest of the flow region in the enclosures. However there were a little differences in the shapes of jet flow in both enclosures for Reynolds numbers of 5 and 10 and also in the shapes of recirculating flows in both enclosures for all Reynolds number. Also it was found that waving flow appeared right before the outlet at Reynolds number of 20 and more.

  • PDF