• Title/Summary/Keyword: Flows Control

Search Result 680, Processing Time 0.025 seconds

Equivalence Between Two Orthogonal Oriented Circular Loops and Planar Inveryed-F Antenna Array (직교형 원형 루프 안테나와 역 에프형 배열구조의 등가성 분석)

  • Kim, Jong-Sung;Park, Seung-Mo;Choi, Won-Kyu;Seong, Nak-Seon
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.289-292
    • /
    • 2005
  • Two planar inverted-F antenna (PIFA) arrays are proposed as an alternative model to generate input and radiation characteristics of two orthogonal oriented circular loops, which has polarization diversity, but inherent mechanical instability of two orthogonal loops, in particular, in installation and operation conditions. Two $1\times2$ PIFA sub-arrays are orthogonally placed on a ground plane and two different feeding networks are applied to control horizontal and vertical radiation current flows for each sub-array, respectively. Equivalence of scattering parameters and radiation patterns between two antennas are validated by the available commercial simulator.

  • PDF

RIO-DC Buffer Design for Core Routers in DiffServ Assured Services

  • Hur, Kyeong
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.5
    • /
    • pp.539-544
    • /
    • 2011
  • In this paper, a parameter optimization method of RIO-DC (RED (Random Early Detection) with In and Out-De-Coupled Queues) scheme for Assured Service (AS) in Differentiated Services (DiffServ) is proposed. In order to optimize QoS (Quality of Service) performance of the RIO-DC policy for AS in terms of maximum tolerable latency, link utilization, fairness, etc., we should design router nodes with proper RIO-DC operating parameter values. Therefore, we propose a RIO-DC configuration method and the admission control criterion, considering the allocated bandwidth to each subclass and the corresponding buffer size, to increase throughput for In-profile traffic and link utilization. Simulation results show that RIO-DC with the proposed parameter values guarantees QoS performance comparable with the RIO scheme and it improves fairness between AS flows remarkably.

NUMERICAL STUDY OF TURBULENT FLOW IN A INTAKE PART OF VACUUM CLEANER WITH ROLLING BRUSH (회전브러시가 장착된 진공청소기 흡입장치의 난류유동에 대한 수치해석)

  • Park, Tae-Seon
    • Journal of computational fluids engineering
    • /
    • v.17 no.2
    • /
    • pp.58-64
    • /
    • 2012
  • Turbulent flows in a intake part of vacuum cleaner are studied by RANS simulations. The governing equations are solved by the SIMPLE algorithm based on the finite volume method of the unstructured grid system. The predicted results show that the suction performance is closely related to the variation of flow structure in the intake part. In order to investigate for the cleaning of bedclothes and carpet without sticking, several design changes are applied. The introduction of a solid cylinder in the intake part changes vortical structures significantly. Based on this result, a new design with spiral brushes is proposed. The design shows a good behavior for the suction performance and the flow control.

A Study on the Characteristics of Flow in the Metal Touch Ball Valve according to the Opening degree (볼밸브의 개폐각도에 따른 유동특성 분석)

  • An, Tae-Won;Han, Geun-Jo;Han, Dong-Seop;Lee, Seong-Wook
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.175-178
    • /
    • 2007
  • Valves has been used widely in various industries. There are many purposes for valve usage in a piping system. One of them is to control the flow rate. For a design of ball valves, it is important to know the characteristics of flows inside a ball valve. In this study, the computation fluid dynamics were conducted to observe flow velocity, flow coefficient and pressure distribution using CFX 10 according to the valve angles and uniform incoming velocity.

  • PDF

Development of Conversational Interface Platform Based on MS Robotics Studio for Integrated Service Robots (통합 서비스 로봇을 위한 MS 로보틱스 스튜디오 기반 대화 인터페이스 플랫폼 구축)

  • Lim, Sung-Soo;Cho, Sung-Bae
    • The Journal of Korea Robotics Society
    • /
    • v.4 no.1
    • /
    • pp.49-55
    • /
    • 2009
  • The development of IT technology makes the functions and services of robots be integrated, and thus the robots become more intelligent and useful. As sophisticated usage of robots has evolved, direct communication by human language is necessary to increase the efficiency of their usage. In this paper, we propose a conversational interface platform for integrated service robots using MS Robotics Studio. The proposed platform consists of three types of components: a conversation manager to control the flows of the integrated service robots, a user interface to interact with users, and multiple service robots to perform actions or services. For a test-bed of the proposed platform, we build a schedule manager system and confirm the usability through SUS subject test by comparing the schedule manager system with MS Outlook.

  • PDF

Interference-limited Resource Allocation in Cognitive Radio Networks with Primary User Protection.

  • Mui, Nguyen Van;Hong, Choong-Seon
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2011.06a
    • /
    • pp.352-354
    • /
    • 2011
  • The performance of multihop cognitive radio networks (CRN) can be improved significantly by using multiple channels in spectrum underlay fashion. However, interference due to the sharing of common radio channel and congestion due to the contention among those flows that share the same links become an obstacle to meet this challenge. How to control efficiently congestion and allocate power optimally to obtain a high end-to-end throughput is a key objective in this work. We reexamined the Network Utility Maximum (NUM) problem with a new primary outage constraint and proposed a novel resource allocation strategy to solve it effectively and efficiently.

Numerical study on fluid flow by hydrodynamic loads in reactor internals

  • Kim, Da-Hye;Chang, Yoon-Suk;Jhung, Myung-Jo
    • Structural Engineering and Mechanics
    • /
    • v.51 no.6
    • /
    • pp.1005-1016
    • /
    • 2014
  • Roles of reactor internals are to support nuclear fuel, provide insertion and withdrawal channels of nuclear fuel control rods, and carry out core cooling. In case of functional loss of the reactor internals, it may lead to severe accidents caused by damage of nuclear fuel assembly and deterioration of reactor vessel due to attack of fallen out parts. The present study is to examine fluid flows in reactor internals subjected to hydrodynamic loads. In this context, an integrated model was developed and applied to two kinds of numerical analyses; one is to analyze periodic loading effect caused by pump pulsation and the other is to analyze random loading effect employing different turbulent models. Acoustic pressure distributions and flow velocity as well as pressure and temperature fields were calculated and compared to establish appropriate analysis techniques.

Extended Petri Nets and Distributed Processor Systems Modeling (확장된 페트리 네트와 분산형 공정 제어의 모델링)

  • Lim, Sung-Ho;Kim, Hyun-Ki;Woo, Kwang-Bang
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.450-454
    • /
    • 1988
  • In order to represent and analyze distributed system design, the model based on an extended form of Petri nets, which enables one to represent both the structure and the behavior of a distributed system, is predented. Behavioral properties of the design representation are verified by translating the extended Petri net into an equivalent ordinary Petri net. The model emphasizes the unified representation of control flows, hierarchical structure, and distributed system state. Modeling technique isemployed for the performance and function analysis of flexible manufacturing system with a set of processors.

  • PDF

Measurements of X-Ray and Gamma Ray Dosse Rate by the Silicon P-N Junction Diode (Silicon P-N Junction Diode에 대한 X-Ray 및 Gamma-Ray 의 Dose Ratec 측정)

  • 정만영;김덕진
    • 전기의세계
    • /
    • v.13 no.3
    • /
    • pp.13-20
    • /
    • 1964
  • The measurements of X-ray and Gamma-ray Dose Rate have been successfully made by measuring the short circuit current of the Silicon P-N Junction Diode being irradiated. The short circuit current flows when a silicon P-N Junction Diode is irradiated by X-ray of Gammaray radiations due to photovoltaic effect. A brief analysis is given in order to verify the proportionality of a short circuit current to the Dose Rate. Using this method, measurements of X-ray Dose Rate were carried out in the range of 0.05-1600 r/m successfully. The calibration was made by comparing with Victoreen condenser r-meter. Some advantages in this Dose Rate meter over a condenser r-meter were found. One can measure a continous variation of X-ray Dose Rate with this rate meter at the control console of X-ray device.

  • PDF

A Power System Economic Operation using Bus Distributed Transmission Loss Information (분산 송전손실정보에 의한 전력시스템의 경제운용)

  • 이봉용;심건보
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.4
    • /
    • pp.333-340
    • /
    • 1990
  • 분산 송전송실정보에 의한 전력시스템의 경제운용=The transmission loss information produced in a line may be shared by both end buses connected to the line. Then, the loss may be seen as if it is discretely produced at both buses. Likewise, all transmission losses can be considered as if they are discretely produced at every bus distributed. The bus transmission loss equation can be defined, in which the loss information about connected lines are contained. This formulation can greatly enhance the computational efficiency for the economic control of both real powers and voltages. It requires solutions of two linear matrix equations, one for the calculation of incremental transmission losses and the other for the determination of voltage levels to be controlled. The Proposed approach is demonstrated through three sample systems and it is found that the solutions can be obtained after three iterations regardless of system sizes. This implies that only one-step search would be required for the solution if real informations would be available. Results are compared with those of optimal power flows.

  • PDF