• Title/Summary/Keyword: Flowmeter

Search Result 262, Processing Time 0.047 seconds

Development of PDMS-based Drag Force-type Flowmeter with Graphite-CNT Composite as Piezoresistive Material (흑연과 CNT 복합체를 압저항체로 하는 PDMS 기반의 바람저항형 유속센서 개발)

  • Sang Jun Park;Min Gi Shin;Noh Yeon Kim;Sang Hoon Lee
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.44-50
    • /
    • 2023
  • In this study, a polydimethylsiloxane (PDMS)-based drag force-type flowmeter was fabricated using a graphite-carbon nanotube (CNT) composite as a piezoresistive material and evaluated. The device was in the form of a cantilever, which was composed of the soft material, PDMS, and fabricated using a mold manufactured by a three-dimensional printer. The cost-effective graphite was mixed with CNTs to serve as a piezoresistive material. The optimal mixing ratio was investigated, and the piezoresistive material formed using a graphite:PDMS:CNT ratio of 1.5:1:0.01 was adopted, which showed a stable output and a high sensitivity. Various forward and backward air flows in the range of 0-10 m/s were measured using the fabricated flowmeter, and both tensile and compression characteristics were evaluated. The measured results showed a stable output, with the resistance change gradually increasing with the air flow rate. Repeatability characteristics were also tested at a repeated air flow of 10 m/s, and the flowmeter responded to the applied air flow well. Consequently, the fabricated device has a high sensitivity and can be used as a flowmeter.

Design and Fabrication of an Electromagnetic Flowmeter (전자기유량계의 설계 및 제작)

  • Lim, Ki-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1385-1392
    • /
    • 2003
  • An electromagnetic flowmeter(EMF) was developed and its characteristics were compared with a commercial EMF. The developed EMF was designed as the 100 mm nominal diameter. A signal processing circuit was also developed for generating the magnetic field and converting the flow signal to flowrate and flow quantity. In order to obtain a more stable and reliable flow signal, the double magnetizing frequency was adopted for magnetizing the coil of the EMF. For the characterization of the developed EMF, the uncertainty of calibrator was estimated within $\pm$0.5 %. The evaluation procedure of the uncertainty followed the ISO Guide to the Expression of Uncertainty in Measurement. It was found that the flow signals between the electrodes were about $\pm$60-$\pm$300$\mu$V, which were sufficient for the discrimination of flowmeter and the protection of noise. The test results against the calibrator showed the good linearity in the range of 3 ㎥/h and 70 ㎥/h. A commercialized design of the EMF based on the current study will be technically more competitive in domestic and foreign market.

An Experimental Study on the Influential Factors of Flow Measurement with Coriolis Mass Flowmeter (코리올리스 질량유량계의 유량측정에 영향을 미치는 인자에 관한 실험적 연구)

  • Lim, Ki-Won;Lee, Woan-Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.12
    • /
    • pp.1699-1707
    • /
    • 2003
  • Coriolis mass flowmeter(CMF), which can measure the mass flow directly, is getting rapid attention for the industrial and custody transfer purpose. In order to study the characteristics and the applicability of CMF, it is tested with the national flow standard system. Two types of sensing tube, U-type and straight type, are employed in the test. Water, spindle oil and viscosity Standard Reference Material whose viscosities are 1, 20 and, 67 $\textrm{mm}^2$/s, respectively, are studied. It is shown that the linearity of CMF is getting deteriorated as the fluid viscosity increases, which is due to the zero drift and the relaxation time of the fluid. To test its applicability in the case of high pressured gas, it is calibrated using compressed air, It shows 1∼l.6 % deviations compared to the calibration results using water. It concludes that the fluid velocity in CMF should be lower than the sonic velocity. In addition, the effects of the vibration from the pipeline and pump on CMF as well as the long term stability are studied.

Measurement Uncertainty Analysis of a Turbine Flowmeter for Fuel Flow Measurement in Altitude Engine Test (엔진 고공 시험에서 연료 유량 측정용 터빈 유량계의 측정 불확도 분석)

  • Yang, In-Young
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.1
    • /
    • pp.42-47
    • /
    • 2011
  • Measurement uncertainty analysis of fuel flow using turbine flowmeter was performed for the case of altitude engine test. SAE ARP4990 was used as the fuel flow calculation procedure, as well as the mathematical model for the measurement uncertainty assessment. The assessment was performed using Sensitivity Coefficient Method. 11 parameters involved in the calculation of the flow rate were considered. For the given equipment setup, the measurement uncertainty of fuel flow was assessed in the range of 1.19~1.86 % for high flow rate case, and 1.47~3.31 % for low flow rate case. Fluctuation in frequency signal from the flowmeter had the largest influence on the fuel flow measurement uncertainty for most cases. Fuel temperature measurement had the largest for the case of low temperature and low flow rate. Calibration of K-factor and the interpolation of the calibration data also had large influence, especially for the case of very low temperature. Reference temperature, at which the reference viscosity of the sample fuel was measured, had relatively small contribution, but it became larger when the operating fuel temperature was far from reference temperature. Measurement of reference density had small contribution on the flow rate uncertainty. Fuel pressure and atmospheric pressure measurement had virtually no contribution on the flow rate uncertainty.

A study on the development of an electromagnetic flowmeter and the characterization of flow signal (전자기유량계의 개발및 신호 특성에 관한 연구)

  • Lim Ki Won;Kim Chang Ho
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.361-364
    • /
    • 2002
  • An electromagnetic flowmeter(EMF) was developed and its characteristics were compared with a commercial EMF. The measuring tube of the EMF was basically designed as 100 m diameter. A signal processing circuit was also developed for generating the magnetic field and converting the flow signal to flowrate and flow quantity. To obtain a more stable and reliable flow signal, the double magnetizing frequency was adopted for magnetizing the coil of the EMF For the characterization of EU, the uncertainty of calibrator was estimated within ${\pm}0.5{\%}$, the method of estimation was in accordance with the ISO 17025 recommendation. It was found that the flow signals between the electrodes were about ${\pm}60\;-\;{\pm}300{\mu}V$, which were sufficient for the discrimination of the flowmeter and protecting the noise. The test result against the calibrator, showed the good linearity in the range of $3 m^{3}/h\;and\;70m^{3}/h$. A commercialized design of the EMF will be technically more competitive in domestic and foreign market.

  • PDF

Development of Small Size Coriolis Mass Flowmeter (소형 코리올리 질량 유량계의 개발)

  • Lim Ki-Won;Ji Jueng-Keun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.6 s.249
    • /
    • pp.497-504
    • /
    • 2006
  • A Coriolis mass flowmeter(CMF), which has U-Shaped unique measurins tube was developed fo. direct mass flow measurement. In order to convert the time difference between two measuring tubes motion into mass flowrate and flow quantity, a signal processing circuit, as a part of CMF, was also developed. The CMF was designed as the 15 mm nominal diameter of pipe connection and the 8 mm stainless steel(sus 316) pipe was used for measuring tube. To maximize the flow signal(time difference) from the measuring tubes, the natural frequency of measuring tube was adjusted as 220 Hz, which is same as the frequency of exciter. The maximum displacement at the end of the measuring tube was measured as 0.05 mm and the maximum time difference between two measuring tubes was observed as $20{\mu}s$, which was proper for discrimination and measuring range of CMF. The developed CMF was tested against the gravimetric flowmeter calibrator in the range of 3 kg/min and 30 kg/min. The results showed that the CMF has good linearity and repeatability in the tested flow range. Large size of CMF base on the current study experience will be developed.