• Title/Summary/Keyword: Flowing water environment

Search Result 166, Processing Time 0.029 seconds

Removal Effects of Organic-Phosphorus Pesticide Residue in lettuce by washing methods (세척방법에 따른 상추중 유기인 잔류농약의 제거효과)

  • Ko, Bok-Sil;Jeon, Tae-Hwan;Jung, Kyu-Saeng;Lee, Sung-Kook
    • Journal of agricultural medicine and community health
    • /
    • v.21 no.2
    • /
    • pp.159-171
    • /
    • 1996
  • It is investigated to determine the removal efficiency of organic - phosphorus insecticide residues in lettuce by washing processes, the 5 washing solution (stagnant tap water, flowing tap water, alkaline solution, acidic solution) were used with the washing time(10, 30, 50sec) and frequencies(1, 2, 3 washing, 2 rinsing). The removal efficiency of residual pesticides by 5 washing methods was increased on the more washing time and frequency, and also was the highest on the 3 times washing for each 50 sec. The removal rate with stagnant tap water was 33.7% of Diazinon, 45.7% of Dimethoate and 24.6% of Fenitrothion, but 29.4% of Diazinon, 37.7% of Dimethoate and 24.5% of Fenitrothion with flowing tap water. Therefore, the former was significantly higher effective than the latter one. The removal rate of residual pesticides with alkaline solution showed 32.1% of Diazinon, 49.5% of Dimethoate and 29.9% of Fenitrothion, and 30.4% of Diazinon, 36.4% of Dimethoate and 21.0% of Fenitrothion with acidic solution. The washing efficiency of neutral detergent showed the most effective result than others with 47.1% of Diazinon, 58.0% of Dimethoate and 39.5% of Fenitrothion. Consequently, it's appeared that the neural detergent washing was the most effective method on the 3 times washing for each 50 sec.

  • PDF

A Study on the Reduction of Total Phosphate of the Concerned Pollution Area in the Main Stream of Mangyeong River (만경강 본류 중 오염우심지역의 TP 저감방안 연구)

  • Jounghwa, Choi;Jaeog, Kwon;Miseon, Lee;Wook, Jang;Geunhwa, Choi;Eunhye, Ko;Seohyeon, Sim;Changwoo, Cho
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.6
    • /
    • pp.316-326
    • /
    • 2022
  • This study aimed to investigate the causes of the increasing Total Phosphate(TP) in the mainstream of Mangyeong river over the past 10 years, and suggested a reduction plan of about 3 points. First, the high TP concentration was continuously released in the discharge outlet of the Haepo bridge stormwater pipeline. The average TP concentration was 5.066 mg/L and values as high as 29.470 mg/L were measured. The highest pollution contribution rate to the Mangyeong river was more than 70 %. The cause of the pollution was expected to take place somewhere in Wanju Industrial Complex. Second, the average TP concentration of wastewater-treated effluent in the H factory was 0.405 mg/L. If a TP reduction facility is additionally installed in the H factory, it will help reduce TP uptake by Lake Saemangeum. Third, the TP concentration of untreated non-point source point flowing into the Samrae stream was very high with an average of 2.828 mg/L. Also, the pollution contribution rate of Samraecheon 2 to Mangyeong river was 21.8 % on average and up to 58 %. The pollution contribution rate was also high during the agricultural season and the winter, during which the flow rate is decreased. Investigation of these three points may be continuously needed, and analysis results and policy proposals presented to Jeollabukdo and Wanjugun to manage pollution sources.

A Study on the Characteristics of Water Quality in the Jinhae Bay (진해만해역의 수질환경특성에 관한 연구)

  • 반영남;국승기
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.255-261
    • /
    • 2004
  • Through spot-investigation and observation of water quality environment of Jinhae Bay, this conducts the sea movement simulation on the current water quality of Jinhae Bay, grasps the flowing characteristics of Jinhae Bay and carries out ocean pollution simulation by using the data collected. Sea movement simulation results are tested by using Ocean Investigation Bureau's data of tide and current, and are also used in the ocean pollution spreading simulation. Water quality spreading simulation is conducted by using the data of sea movement and data of observation and then the results are compared with data of spot investigation. COD condensity is calculated and the water quality characteristics of Jinhae Bay are grasped.

  • PDF

Development of Waterworks Piping MHD Technology for USN Advancement in U-City/BIM (U-City/BIM USN 고도화를 위한 상수도배관용 자기유체발전 기술 개발)

  • Hwang, Jung-Rae;Lee, Hyun-Dong;Oh, Yoon-Seuk;Kwak, Pill-Jae;Kim, Gi-Eun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.4
    • /
    • pp.555-563
    • /
    • 2012
  • Due to the importance of energy-saving and CO2 reduction is being emphasized in the world, efforts to find a solution for the problems is increasing rapidly. In particular, the renewable energy is on understanding as a breakthrough for the protection of the environment and the economic development, so it is intensively fostered as future industries. Developed countries are already pursuing policy and technology development related with renewable energy. In this paper, we will develop MHD(Magneto Hydro Dynamics) technology to supply the commercial power that can is targeted at water pipe related with hydro power among renewable energy technologies. Kinetic energy of fluid flowing in the water pipe is converted into electric power. It allows stable power supply to the various sensors and devices on water pipe. We have performed several experiments to verify the application possibility of the developed technologies and present the result and a method of performance improvement of the technologies.

Analysis of Nonpoint source Reduction at Andong Area Considering Changes in CN (CN의 변화에 따른 안동시 물순환 선도도시 조성계획의 비점오염부하 저감효과 분석)

  • Kwon, Heongak;Jung, Kangyoung;Kim, Shin;Shin, Sukho;Ahn, Jungmin;Kim, Gyeonghoon
    • Journal of Wetlands Research
    • /
    • v.18 no.4
    • /
    • pp.342-349
    • /
    • 2016
  • Andong belongs to the Nakdong River Basin, Nakdong River is flowing through the city, including Andong dam and Imha dam. The runoff due to provincial transfer and impervious area has been increasing by urbanization increases and nonpoint source loads. In this study, we evaluate the runoff and nonpoint pollution loads in accordance with the development targeted at selected urban water cycle leading to Andong city. Andong city leading to the water cycle plan to evaluate the directly runoff and BOD, T-N and T-P nonpoint pollutant loads using the CN into account the temporal and spatial changes. Evaluation, direct runoff per year is 10.41 % if the green roof and a water permeable pavement replacement, water cycle parks and streets compositions, City impermeable layer improvements to be business including four kinds of scenario is applied to both the development and the BOD non-point pollutant loads 20.56%, T-N 9.55% and T-P pollution and nonpoint loads was investigated to be reduced 14.29%. Four kinds of low lapse rate of the development scenario of the highest thing urban impervious surface was investigated by improving business development prior year annual direct runoff is 6.25 %, BOD nonpoint pollution loads are 11.84%, T-N nonpoint pollution loads are 4.46 % and T-P was investigated by reducing pollutant loads to be 10.20%.

A Study on multi-channel temperature monitoring for the detection of leakage or seepage in dam body (댐 침투수 탐지를 위한 멀티 채널 온도 모니터링 연구)

  • Oh, Seok-Hoon;Kim, Jung-Yul;Park, Han-Gyu;Kim, Hyoung-Soo;Kim, Yoo-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1211-1218
    • /
    • 2005
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF

The Change Detection of SST of Saemangeum Coastal Area using Landsat and MODIS (Landsat TM과 MODIS 영상을 이용한 새만금해역 표층수온 변화 탐지)

  • Jeong, Jong-Chul
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.2
    • /
    • pp.199-205
    • /
    • 2011
  • The Saemangeum embankment construction have changed the flowing on the topography of the coastal marine environment. However, the variety of ecological factors are changing from outside of Saemangeum embankment area. The ecosystem of various marine organisms have led to changes by sea surface temperature. The aim of this study is to monitoring of sea surface temperature(SST) changes were measured by using thermal infrared satellite imagery, MODIS and Landsat. The MODIS data have the high temporal resolution and Landsat satellite data with high spatial resolution was used for time series monitoring. The extracted informations from sea surface temperature changes were compared with the dyke to allow them inside and outside of Saemangeum embankment. The spatial extent of the spread of sea water were analyzed by SST using MODIS and Landsat thermal channel data. The difference of sea surface temperature between inland and offshore waters of Saemangeum embankment have changed by seasonal flow and residence time of sea water in dyke.

Purification of Water Contaminants Using Activated Carbon Fiber Filter with Phenolic Resin Coated on Glass Fibers as a Precursor

  • Baek, Il-Hyun
    • Carbon letters
    • /
    • v.1 no.2
    • /
    • pp.82-86
    • /
    • 2000
  • The present research was undertaken to evaluate the possibility of water purification filter with activated carbon fibers (ACFs) using a very low cost precursor consisting of phenolic resin coated on glass fibers. The simplified procedure involving coating, curing and activation and a very low cost glass fiber as a raw material were adopted in order to reduce manufacturing cost. The breakthrough curves of the manufactured ACFs and the commercial activated carbon (AC, Calgon F-200) were investigated in the initial concentration range from 19 to 49 ppm for benzene, toluene and ethylbenzene. From breakthrough profiles, the manufactured ACFs had significantly faster adsorption kinetics than the AC. Especially the benzene breakthrough curves, the manufactured ACF (13 g of ACF with 32% of carbon on the glass) was over the limited level (5 ppb) after flowing of 32 l at initial concentration of 15 ppm, while the commercial AC was shown about 3 ppm in initial adsorption.

  • PDF

임기광산 폐석적치장의 수리침투특성 분석

  • 지상우;정영욱;임길재
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.394-398
    • /
    • 2004
  • This study was carried out to plan the prevention of the generation and discharge of acid mine drainage (AMD). Hydraulic characteristics were tested with the disk tension infiltrometer around the waste rock dump of the Imgi abandoned pyrophyllite mine in Busan, Korea. Because the waste rock dump of the Imgi mine have very low infiltration rate, most of rain was expected flowing into adjoined stream through the slope or plane as surface flow rather then throughflow or ground water. But slopes of the waste rock dump have many 'V' type erosion gullies and consist multi-layers. These gullies and multi-layers have coarse clastic particle layer which have very large hydraulic conductivity. So through these coarse clastic particle layers a large part of rain flow into ground. And also these layers could be played a function of aeration path, which induced oxidation of sulfide minerals and generation of AMD continuously.tinuously.

  • PDF

Cluster and Factor Analyses Using Water Quality Data in the Sapkyo Reservoir Watershed (삽교호유역의 수질자료를 이용한 군집분석 및 요인분석)

  • Im, Chang-Su;Sin, Jae-Gi
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.2
    • /
    • pp.149-159
    • /
    • 2002
  • The monthly water quality data measured at 19 stations located in the Sapkyo reservoir watershed were clustered into 2 to 7 clusters and factor analysis was conducted to characterize the water quality, using the information obtained from cluster analysis. The result of cluster analysis shows that Sapkyo reservoir and each stream (Sapkyo stream, Muhan stream and Kokkyo stream) in Sapkyo reservoir watershed hove their own water quality characteristics. The result of water quality analysis indicates that the concentration of suspended solids from Sapkyo reservoir is much higher than those of other streams, and which is probably because of increment of phytoplankton biomass with rich nutrient flowing Into Sapkyo reservoir from the upper stream of watershed. Furthermore, the concentrations of biochemical oxygen demand and chemical oxygen demand were 3.5 to 4.8 times and 1.7 to 2.5 times those of other streams, respectively. The overall water quality of Sapkyo reservoir watershed was considered to exceed eutrophic condition. Based on factor analysis, the water quality characteristics of Sapkyo stream and Muhan stream were closely related with farm land and residence. The water quality of Kokkyo stream was influenced by superabundant organic matter flowing from Chonan city and district wastewater treatment plant located in the upper stream of Kokkyo stream. The water quality factor influencing Sapkyo reservoir was closely related with water quality factors of other three streams.