• Title/Summary/Keyword: Flowing

Search Result 2,390, Processing Time 0.035 seconds

The comparison and investigation of harmonic magnification according to power supply schemes in high speed railway (고속철도의 급전계통 구성에 따른 고조파 확대율 비교 검토)

  • Lee, Chang-Mu;Oh, Kwang-Hae;Chang, Sang-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1402-1404
    • /
    • 2000
  • The electrified railway has various power supply schemes. Although the identical trains are operated in same condition and the impedance of track are equal, the genealogy impedance of track is changed according to composition method of feeding scheme. So, the harmonic current flowing into the railway substation are greatly unlike. For simulation of harmonic magnification flowing into the railway substation according to feeding scheme, we propose 6-port network analysis method based on 4-port network, find 6-port equivalent model of each circuit component, and compare and investigate harmonic magnification in the case of parallel post and normal feeding scheme.

  • PDF

Performance of a Shell-and-Tube Heat Exchanger with Spiral Baffle Plates

  • Son, Yeong-Seok;Sin, Ji-Yeong
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.11
    • /
    • pp.1555-1562
    • /
    • 2001
  • In a conventional shell-and-tube heat exchanger, fluid contacts with tubes flowing up and down in a shell, therefore there is a defect in the heat transfer with tubes due to the stagnation portions . Fins are attached to the tubes in order to increase heat transfer efficiency, but there exists a limit. Therefore, it is necessary to improve heat exchanger performance by changing the fluid flow in the shell. In this study, a highly efficient shell-and-tube heat exchanger with spiral baffle plates is simulated three-dimensionally using a commercial thermal-fluid analysis code, CFX4.2. In this type of heat exchanger, fluid contacts with tubes flowing rotationally in the shell. It could improve heat exchanger performance considerably because stagnation portions in the shell could be removed. It is proved that the shell-and-tube heat exchanger with spiral baffle plates is superior to the conventional heat exchanger in terms of heat transfer.

  • PDF

Direct Numerical Simulation of Turbulent Heat Transfer to Water at Supercritical Pressure Flowing in Vertical Pipes (수직원형관내 초임계압 물의 난류 열전달에 관한 직접수치모사)

  • Lee, Sang-Hoon;Bae, Joong-Hun;Yoo, Jung-Yul
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2471-2476
    • /
    • 2008
  • Turbulent flow and heat transfer to water at supercritical pressure flowing in vertical pipes is investigated using direct numerical simulation (DNS). A conservative space-time discretization scheme for variable-density flows at low Mach numbers is adopted in the present study to treat steep variations of fluid properties at supercritical pressure just above the thermodynamic critical point. The fluid properties at these conditions are obtained using PROPATH and used in the form of tables in the simulations. The buoyancy influence induced by strong variation of density across the pseudo-critical temperature proved to play an important role in turbulent flow and heat transfer at supercritical state. Depending on the degree of buoyancy influence, turbulent heat transfer may be enhanced or significantly deteriorated, resulting in local hot spots along the heated surface.

  • PDF

Experimental Study on Heat Transfer Performance of Oil Cooler (오일 쿨러의 열전달 성능에 관한 실험적 연구)

  • Cho, Dong-Hyun;Lim, Tae-Woo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2328-2333
    • /
    • 2008
  • The experimental study was carried out to evaluate the heat transfer performance on the shell side of shell-and-plate finned tube heat exchanger with three different tube numbers(9, 13 and 19). Oil flowing on the shell side was cooled by cold water flowing inside the tubes. A shell-and-tube heat exchanger of an oil cooler consisted of one shell pass and two tube passes with the inner tube diameter of 8.82 mm and the tube length of 575 mm. Mass flow rate was varied from 1.2 to $6.0\;m^3/h$ for oil and from 0.6 to $3.0\;m^3/h$ for cold water, respectively. From the experiment of shell-and-plate finned tube heat exchanger, the shell side heat transfer coefficient of heat exchanger with 9 tubes was compared with that of 13 and 19 tubes. It was found that the heat exchanger with 9 plate finned tubes showed more performance of heat transfer than that of 13 and 19 tubes.

  • PDF

Characterization of Liquid Phase LPG Sprays within Airflow Fields (LPG 액상분무의 분열 및 혼합특성)

  • 최재준;최동석;남창호;배충식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.90-97
    • /
    • 2002
  • The interaction between airflow and liquid phase LfG (Liquefied Petroleum Gas) sprays was investigated in a steady flow system embodied in a wind tunnel to simulate the variety of flow inside intake port of LPG engines with liquid injection system. The spray developments in flowing fields with the mean velocities of 5.4, 21.5 and 42.4m/s were identified by spray visualization techniques such as Mie scattering and shadowgraph. The microscopic visualization using a telescopic lens system was performed to investigate the shape and size of liquid droplets in the spray. PDA measurement was used to get 1-dimensional velocity and diameter of liquid droplets. The fast co-flows make the spray field be compact and be lead upward to the injection direction. SMD of the spray was smaller at the fast flowing field. Spray width got bigger and SMD of the spray was smaller with higher injection pressure.

The Influence of the Volume Contents of Sand in Mortar on the Properties of Self Compacting Concrete (잔골재 용적비가 고유동 콘크리트의 성질에 미치는 영향)

  • Choi Jae-Jin;Yoo Jung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.755-758
    • /
    • 2004
  • Self-compactability is defined as a capability of concrete to be uniformly filled and compacted in every corners of formwork by its self-weight without vibration during placing. To evaluate the self compactability of self compacting concrete, the slump flow, the time of slump flow at 500mm and U-box apparatus testing methods are used. In this research, the fresh and hardened properties of self compacting concrete using ground granulated blast furnace slag as a part of cement were investigated for the volume contents of sand in the mortar. The workability, flowing characteristics, air content and compressive strength of concrete were tested and the results were compared with the different volume contents of sand in the mortar. In the experiment, we acquired satisfactory results at the point of flowing characteristics and strengths of self compacting concrete.

  • PDF

Strength Propreties of Binary and Ternary Blended of Ultra Flowing Self-Compacting Concrete (2성분계 및 3성분계 초유동 자기충전 콘크리트의 강도 특성)

  • Choi, Yun-Wang;Kim, Kyung-Hwan;Ha, Sang-Woo;Moon, Dae-Joung;Kang, Hyun-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.489-492
    • /
    • 2006
  • Needs for the new technologies and cutting-edge Ultra Flowing Self-Compacting Concrete are emerging as the concrete structures are becoming bigger and more specialized recently. In North America and Europe, SCC, which has high resistance against flow ability and segregation, is being used as concrete material in applications such as precast and prestressed bridges, where reinforcing bars are overcrowdedly placed. In Korea, SCC has been utilized limitedly in building structures but its utilization should be expanded to engineering structures such as bridges. In this study, for the application in precast and prestressed bridges with overlycrowded reinforcing bars, USCC was mixed with admixtures to give a binary system and a ternary system according to the 1st grade rules by JSCE (Japan Society of Civil Engineers). Compressive strength and splitting tensile strength of the resulting USCCs were tested. Elastic modulus were compared with the values suggested in CEB-FIP code and ACI 318-05.

  • PDF

Properties of Water Content Variances in Ultra High Flowing Concrete Before and After the Pumping Operation (현장적용 초유동 콘크리트의 펌프압송 전후 단위수량 변화 특성)

  • Kim, Kyoung-Min;Yoo, Jae-Kang;Shin, Hong-Cheol;Choi, Jong-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.401-404
    • /
    • 2006
  • This study is the part of the investigation of the state of the art in ultra high flowing concrete (UHFC), applied in practical field construction, in order to develop the technology for improving workability. This paper includes a brief introduction of water content variance properties in UHFC before and after the pumping operation. Test showed that water content in all parameters decreased after the pumping. This is due to the increase of an absorption ratio of coarse aggregate by the pressure of the pumping operation. thus decreasing the water content. Therefore it should be considered to find out the possibility, which can improve the workability, suffering from over viscosity by the lower water content, in field construction.

  • PDF

Synthesis and Characterization of Gallium Nitride Powders from a Gallium(III) Sulfate Salt in Flowing Ammonia

  • Jung, Woo-Sik
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.11
    • /
    • pp.1058-1061
    • /
    • 2003
  • Gallium Nitride (GaN) powders were synthesized by calcining a gallium(III) sulfate salt in flowing ammonia in the temperature range 500-1100$^{\circ}C$. The process of conversion of the salt to GaN was monitored by X-Ray Diffraction (XRD). The salt decomposed to ${\gamma}$-Ga$_2$O$_3$ and then converted to GaN without ${\gamma}$-${\beta}$Ga$_2$O$_3$ phase transition. Variations in XRD patterns and weight loss of samples with temperature indicate that the conversion of ${\gamma}$-Ga$_2$O$_3$ to GaN does not proceed through Ga$_2$O but stepwise via amorphous gallium oxynitride (GaO$\_$x/N$\_$y/) as intermediates. Room-temperature photoluminescence spectra of GaN powders obtained showed the emission peak at 363 nm and no yellow band.

Frequency dependences of leakage currents flowing through ZnO varistor (ZnO 바리스터에 흐르는 누설전류의 주파수 의존성)

  • Lee, Bok-Hee;Lee, Bong;Kang, Sung-Man
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2166-2168
    • /
    • 2005
  • This paper presents the frequency - dependent characteristics of leakage currents flowing through ZnO varistor. The leakage current - voltage (V-I) characteristic curves of the commercial ZnO varistor were measured. The resistive leakage current was increased with increasing the magnitude and frequency of the applied voltage in the low conduction region. The power losses of ZnO varistor increase as the frequency of applied voltage increases, because of the dielectric loss related to the frequency of the test voltage.

  • PDF