• Title/Summary/Keyword: Flow-supply Characteristics

Search Result 449, Processing Time 0.028 seconds

A Study on the Development of the Water Hammering Cleaner System for Pipeline (수격파를 이용한 배관 세정기 개발 연구)

  • Kim H.-S.;Kim Youn J.;Park K.-J.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.675-678
    • /
    • 2002
  • In order to develop the water hammering cleaner system for removing scale and slime in inner metal or non-metal piping wall, the flow characteristics are investigated by numerical and experimental methods. The air bubbles in the piping systems as a shock wave are formed and transferred with the water flow in the piping. The governing equations are derived from making using of three-dimensional Wavier-Stokes equations with the standard $k-{\varepsilon}$ turbulence model and SIMPLE algorithm. Pressure distributions in the pipeline are calculated for different air supply pressures. Also, we prepared some experimental results of the pressure differences for various air supply times.

  • PDF

Analysis on the Dynamic Characteristics of Externally Pressurized Porous Thrust Air Bearings (다공질정압 Thrust공기 베어링의 동특성 해석)

  • Park, Cheon-Hong;Lee, Hu-Sang
    • 연구논문집
    • /
    • s.23
    • /
    • pp.5-13
    • /
    • 1993
  • The present work deals with the theoretical prediction of static & dynamic characteristic of annular type externally pressurized thrust air bearings with metal-sintered porous media. For the evaluation of surface loading effect by machining, it is assumed that the flow at the porous surface is dominant and which is equivalent to the flow through orifice. Finite different method with over-relaxation method is used to solve the numerical problems. The influences of radius ratio, supply pressure and squeeze number on performances are investigated, as the results. The results of this study can be used to predict the optimal running condition and stable realm of porous bearings.

  • PDF

Aeration Efface on the Oil Supply System of Engine Crankshaft Bearing (Aeration이 엔진 크랭크샤프트 베어링 오일공급 시스템에 미치는 영향)

  • 윤정의
    • Tribology and Lubricants
    • /
    • v.20 no.3
    • /
    • pp.119-124
    • /
    • 2004
  • Engine bearing system is generally affected by aeration. In this paper, the aeration effects on the engine crankshaft bearing system were studied. To do this, unsteady oil flow analysis on the engine crankshaft oil circuit system was carried out. And aeration effects on the bearing system were simulated to figure out lubrication characteristics of the each bearing such as oil flow rate, minimum oil film thickness, friction loss and increase of oil temperature.

An Analytical Investigation of the Characteristics of Four-Nozzle Flapper Valve (4-노즐 플렙퍼 밸브 특성에 대한 해석적 고찰)

  • 이재천
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.161-166
    • /
    • 2001
  • The static characteristics of four-nozzle flapper valves are investigated with both constant flow and constant supply pressure. The ranges, in which linearization of these characteristics would be valid, are discussed. Linearized dynamic model is also derived. Numerical simulations of nonlinear dynamic model are carried out by HyPneu to make an assessment of the effect of input step size in both cases of no-load and blocked-load operation.

  • PDF

Velocity and Spray Characteristics under Swirl Flows in a Model Combustor (모델연소기 선회유동장에서의 속도 및 분무특성)

  • Bae, C.S.;Lee, D.H.
    • Journal of ILASS-Korea
    • /
    • v.3 no.2
    • /
    • pp.42-50
    • /
    • 1998
  • The effect of swirl flows un the fuel spray characteristics were investigated for various swillers in a model combustor. The interaction between the flow field and fuel spray in the main combustion tone made by frontal devices including fuel injection nozzles and swirlers. which were characterized by flow velocities, fuel droplet sizes and their distributions which were measured by APV(Adaptive Phase/Doppler Velocimetry) under atmospheric condition at 320cc/min kerosine fuel flow and 0.04kg/sec air supply. A dual swirler with circumferential two-stage swirl vanes of $40^{\circ}\;and\;45^{\circ}$ vanes in different directions and two single-stage swillers of $40^{\circ}$ vanes with 12 and 16 vanes were tested. It was found that the dual swirler has the largest recirculating zone with highest reverse flow velocity. The strongest swirl flow was found at the boundary of recirculation zone. Small fuel droplets were observed in the main axial stream and inside the recirculation zone when swirling flow field were generated by the frontal devices. These findings could give the tips on the optimal design of frontal devices to realize low emissions in gas turbine combustion.

  • PDF

Ignition Characteristics of Combustion Chamber with $LO_X$ Lead Cyclogram for Liquid Rocket Engine (액체로켓엔진 연소기 산화제 선공급 Cyclogram에 의한 점화특성)

  • Han, Yeoung-Min;Kim, Jong-Gyu;Lee, Kwang-Jin;Lim, Byoung-Jik;Ahn, Kyu-Bok;Kim, Mun-Ki;Seo, Seong-Hhyeon;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.137-142
    • /
    • 2008
  • Ignition characteristics of combustion chamber with LOx lead cyclogram for liquid rocket engine were described. The combustion chamber has chamber pressure of 60 bar, propellant mass flow rate of 89 kg/s, and nozzle expansion of 12. Cold flow test to determine the filling time of propellant for cyclogram with LOx lead supply, ignition test to check the ability to ignite starting fuel from the ignitor, low pressure combustion test to check the propagation of flame into main fuel-oxidizer mixture from starting fuel and the main combustion stage, and design point combustion test to check the combustion performance were performed. Ignition and combustion tests with LOx lead supply were successfully performed and the stable cyclogram of start sequence for combustion chamber was developed.

  • PDF

Flow Analyses around Intake within Sump in a Pump Station (펌프장에서 Sump내 흡입구 주위의 유동해석)

  • Roh Hyung-Woon;Kim Jae-Soo;Suh Sang-Ho
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.597-600
    • /
    • 2002
  • In general, the function of intake structure, whether it be a open channel, a fully wetted tunnel, a sump or a tank, is to supply an evenly distributed flow to a pump station. An even distribution of flow, characterized by strong local flow, can result in formation of surface or submerged vortices, and with certain low values of submergence, may introduce air into pump, causing a reduction of capacity and efficiency, an increase in vibration and additional noise. Uneven flow distribution can also increase or decrease the power consumption with a change in total developed head. To avoid these sump problems pump station designers are considered intake structure dimensions, such as approaching upstream, baffle size, sump width, width of pump cell and so on. From this background, flow characteristics of intake within sump are Investigated numerically to obtain the optimal sump design data. The sump model is designed in accordance with HI code.

  • PDF

DEVELOPMENT OF A NEW LOAD FLOW TECHNIQUE CONSIDERING FREQUENCY AND CONTINGENCY ANALYSIS USING SENSITIVITY (주파수를 고려한 전력 조류 계산 및 감도에 의한 상정사고 해석)

  • Park, Young-Moon;Son, Myoung-Ki;Choo, Jin-Boo;Yoon, Yong-Beom;Lee, Kyung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.201-204
    • /
    • 1992
  • In the conventional load flow technique, it is assumed that the generator at the slack bus is used to supply the transmission losses and the change of power due to the generator outage. The assumption is not true in physical sense. This paper presents a new load flow technique that considers the governor-frequency characteristics and load-frequency characteristics and the technique is consistent with the actual power system phenomenon. This paper proposes an efficient methodology using sensitivity with the new technique for contingency analysis, which is used to calculate the line flows. Computational results of this technique applied to IEEE 14-bus system are presented.

  • PDF

Analysis on Characteristics of Thermal Flow of Hot Air in Single Shell of Shell and Tube-type Heat Exchanger (쉘앤튜브형 열교환기의 단일 쉘 내 고온공기 열유동 특성 해석)

  • Young-Joon Yang
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.2_2
    • /
    • pp.255-263
    • /
    • 2023
  • The shell and tube-type heat exchangers have been frequently used in many industrial field because of its simple structure and wide operation conditions and so on. The purpose of this study is to investigate the flow characteristics in single shell of shell and tube-type heat exchanger according to velocity and temperature of hot air released from heat exchanger simulator through numerical analysis. As the results, the temperature was decreased in almost quadratic curve from top to bottom in single shell of the shell and tube-type heat exchanger. Further the changes of pressure and velocity in outlet according to change of inlet temperature were not observed. The cost for operating the shell and tube-type heat exchanger should be compared the supply cost of hot air with that of velocity in order to make a economic decision.

A Study on Power Flow Method of Radial Distribution System using a measured data from FRTU in Distribution Automation System (배전자동화 시스템의 단말장치(FRTU)로부터 취득되는 데이터를 이용한 방사상 배전계통 조류계산 방법에 관한 연구)

  • Kim, Hyung-Seung;Choi, Myeon-Song;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.286-287
    • /
    • 2015
  • Currently, Studies on improving the reliability of power supply is becoming an important issue because of the increase in demand of the electric power system. Therefore necessity of automation in distribution system is increasing day by day. However, a measured voltage data from FRTU of distribution automation system is incorrect because of installation space limits. Therefore there is a need of system analysis method by considering the characteristics of the distribution system. For a distribution system, applying the power flow method of transmission system has some problems, as distribution is radial system and it has unbalanced load. Therefore power flow by considering the characteristics of the distribution system have been studied. Existing power flow analysis of the distribution system has different methods like direct analysis method, backward/forward sweep method, modified method of newton raphson etc. In this paper, an improved power flow analysis method based on backward/forward sweep method is proposed in order to efficiently operate the distribution automation system. The proposed method of power flow has been verified through the result of case study.

  • PDF